Enhancing Your Bioresearch<br />

Breakthroughs<br />

What’s NEW In Innovative Products For Bioresearch...<br />

Volume 2, Series 55<br />

www.harvardapparatus.com • 508.893.8999 Since 1901<br />

SPECIAL PUMP EDITION<br />

NEW<br />

MRI Compatible <strong>Pump</strong><br />

NEW<br />

Physio 22 Low RFI <strong>Pump</strong><br />

High Pressure Syringe <strong>Pump</strong><br />

PHD 22/2000 Hpsi<br />

MRI Compatible Syringe <strong>Pump</strong> Meets the<br />

Needs of the MRI Environment<br />

Constructed of non-ferromagnetic<br />

metals! Ideal for<br />

drug delivery and tracer<br />

studies!<br />

Bring pumping action as<br />

close as 2-3 feet from the<br />

magnet. The Run/Stop<br />

switch on the syringe pump<br />

head lets you control pump<br />

functions, standing next to<br />

the MRI.<br />

FEATURES<br />

• Programmability<br />

• Pulseless Flow<br />

• High precision<br />

(±0.35%)<br />

• High reproducibility<br />

• High linear force<br />

(66 lbs)<br />

Please visit us at www.harvardapparatus.com for specifications.<br />

Low EMI Syringe <strong>Pump</strong>s For Perfusing<br />

Near Sensitive Physiological Sensors<br />

Now the PHD 22/2000 Series and the Physio 22 Syringe<br />

<strong>Pump</strong>s have virtually no electrical noise emitted so that they<br />

can be used in close proximity to sensitive sensors without<br />

causing any noise interference. This feature is ideal for cell<br />

physiology experiments.<br />

See pages A31 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />

Line Catalog.<br />

The <strong>Harvard</strong> PHD 22/2000<br />

Hpsi pump is a specialized<br />

pump that provides high pressure<br />

and high volume flow.<br />

It was designed to hold the<br />

<strong>Harvard</strong> Stainless Steel<br />

syringes. It provides up to<br />

433 pounds of pumping<br />

force. A single 200 milliliter<br />

stainless steel syringe can<br />

provide a flow rate up to<br />

112 milliliters/minute! Gang<br />

the output of 4 syringes and<br />

that value quadruples. The<br />

pump is a remote model<br />

PHD 4400 Hpsi<br />

FEATURES<br />

PHD 4400 Hpsi<br />

• Delivers >200 lbs<br />

(91 kg) linear pumping<br />

force across a wide<br />

flow rate range<br />

• Accurate and smooth flow<br />

• Ideally suited for<br />

stainless steel syringes<br />

where the control box is separated from the pumping mechanism<br />

by a 152 cm (60 in) cable. A longer cable is also available<br />

should your application require it.<br />

See pages A16 and A18 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />

Full Line Catalog.<br />

MASS SPEC PUMPS<br />

`<br />

NEW<br />

Nanomite Micro Injector<br />

<strong>Pump</strong><br />

Standard Infuse/Withdraw <strong>Pump</strong><br />

11 Pico Plus Syringe <strong>Pump</strong><br />

Versatile PHD 22/2000 Advanced<br />

Syringe <strong>Pump</strong>s<br />

Preserve Precious Materials.<br />

Direct Inject! No Compliance Issues!<br />

The new Nanomite Micro<br />

Injector <strong>Pump</strong> is a miniature<br />

precision pump which allows<br />

accurate injection of the<br />

smallest of volumes, even to<br />

nanoliter ranges. It combines<br />

an injector pump head and<br />

the body of <strong>Harvard</strong><br />

<strong>Apparatus</strong> <strong>Pump</strong> 11 Syringe<br />

<strong>Pump</strong>. New safety features<br />

and microstepping make it<br />

the perfect pump for<br />

DIRECT microinjections in<br />

tight places.<br />

Please visit us at<br />

www.harvardapparatus.com for<br />

specifications.<br />

7 1 ⁄4"<br />

FEATURES<br />

• The linear force to handle<br />

gas tight syringes<br />

• A new Volume Dispense<br />

Alarm when dispensing<br />

is complete<br />

• Safeguard Alarm chimes<br />

when pumping stops<br />

• BrightBlue LED Run<br />

Indicator<br />

• QuickFill for Fast-Infuse<br />

and Fast-Withdraw<br />

• Flow range in picoliters,<br />

nanoliters or microliters!<br />

Lowest Flow Rates!<br />

The <strong>Pump</strong> 11 Pico Plus is the lowest flow rate pump that<br />

<strong>Harvard</strong> <strong>Apparatus</strong> manufactures. It can accurately deliver<br />

volumes down to 3.3 picoliters/minute. It is ideal for<br />

applications such as cellular injections or for providing the micro<br />

flow required for FIA or capillary LC. It has both infusion and<br />

withdrawal capabilities as well as RS-232 communications.<br />

See page A9 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

The <strong>Harvard</strong> PHD<br />

22/2000 Advanced<br />

Syringe <strong>Pump</strong> family is<br />

the most versatile of the<br />

pump lines. This pump<br />

is available for infusion<br />

only or infuse/withdraw<br />

models. This is the only<br />

pump that is available<br />

PHD 22/2000 with Microliter Rack in a Push/Pull configuration.<br />

All PHD pumps<br />

have RS-232 communications capabilities. Specialized<br />

PHD 22/2000 models are programmable directly from the<br />

keypad. In addition, a multitude of syringe racks are available<br />

to hold 2, 4 or up to 10 syringes. A microliter syringe rack is<br />

also available for microliter applications. Remote versions are<br />

available where the control box and pumping mechanism are<br />

separated by a 9.1 meter (30 foot) cable.<br />

See pages A12 to A15 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />

Full Line Catalog.<br />

P AGE 1<br />

<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs www.harvardapparatus.com • 508.893.8999


Enhancing Your Bioresearch<br />

Volume 2, Series 55<br />

Breakthroughs<br />

What’s NEW In Innovative Products For Bioresearch...<br />

www.harvardapparatus.com • 508.893.8999 Since 1901<br />

NEW<br />

Nanomite Micro<br />

Injection <strong>Pump</strong><br />

REMOTE PUMPS<br />

Remote, Infuse/Withdraw &<br />

Programmable High Pressure<br />

PHD Syringe <strong>Pump</strong>s<br />

COMPUTER<br />

CONTROL<br />

LabView Drivers - Take Control<br />

of Your Syringe <strong>Pump</strong>s<br />

7 3 ⁄4"<br />

Injector<br />

Head<br />

Measures<br />

Only 7 3 ⁄4"!<br />

PHD 22/2000 Remote<br />

Control with 6/10 Multi-Rack<br />

FREE!<br />

The new Nanomite<br />

Micro Injector <strong>Pump</strong> is a<br />

miniature precision pump<br />

which allows accurate<br />

injection of the smallest of<br />

volumes, even to nanoliter<br />

ranges. It combines an<br />

injector pump head and the<br />

body of <strong>Harvard</strong> <strong>Apparatus</strong><br />

<strong>Pump</strong> 11 Syringe <strong>Pump</strong>.<br />

New safety features and<br />

microstepping make it the<br />

perfect pump for DIRECT<br />

microinjections in tight<br />

places.<br />

Please visit us at<br />

www.harvardapparatus.com for<br />

complete details.<br />

FEATURES<br />

• Micro-inject small fluid<br />

volumes precisely.<br />

• Five pounds of pumping<br />

force!<br />

• BrightBlue LED run<br />

light indicator.<br />

• Perfect for space limited<br />

applications.<br />

• End-of-Run and safety<br />

alarms.<br />

• Six foot cable allows<br />

safe operation and<br />

injection in a sterile<br />

hood, or from behind<br />

a barrier<br />

Standard Infuse/Withdraw<br />

<strong>Harvard</strong> 33 Dual Syringe <strong>Pump</strong><br />

Every version of the<br />

PHD 22/2000 <strong>Pump</strong> is now<br />

available with a stronger<br />

motor that can provide more<br />

force. These pumps are<br />

ideal when working with<br />

viscous fluid or when driving<br />

multiple syringes. The<br />

standard force PHD<br />

22/2000 series syringe<br />

pump delivers an average nominal force of 50 lbs. while the<br />

high power version delivers 66 lbs of linear force. If you<br />

require even greater force see the PHD 22/2000 Hpsi or the<br />

<strong>Pump</strong> 4400 Hpsi.<br />

See pages A12 to A15 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />

Line Catalog.<br />

CONTINUOUS FLOW<br />

FEATURES<br />

• High accuracy and<br />

precision.<br />

• Low flow rate.<br />

• Ultimate flexibility<br />

and versatility.<br />

• 2 year warranty.<br />

<strong>Harvard</strong> PHD 22/2000 Push/Pull<br />

Syringe <strong>Pump</strong><br />

LabVIEW Drivers<br />

for <strong>Harvard</strong> <strong>Apparatus</strong><br />

PHD 22/2000 and<br />

model 11 Syringe<br />

<strong>Pump</strong>s is built using the<br />

popular LabVIEW <br />

programming application from National Instruments. Control<br />

many pumps, write special applications or integrate into existing<br />

applications. Contact <strong>Harvard</strong> <strong>Apparatus</strong> to get your free copy.<br />

See page A21 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog<br />

SPECIALTY<br />

PUMPS<br />

10-Syringe Feeding System <strong>Pump</strong><br />

This 10-Syringe<br />

Feeding System is a<br />

convenient and<br />

versatile system providing<br />

a method to feed<br />

multiple animals simultaneously,<br />

making it<br />

ideal for multiple animal<br />

feeding studies or other applications which require precise<br />

parallel pumping. The standard syringe rack can hold up<br />

to 10 syringes ranging in size from 50cc to 140cc.<br />

See page A32 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog<br />

33 Dual Syringe <strong>Pump</strong><br />

Continuous Infusion 24 hours a day,<br />

7 days a week, 365 days a year!<br />

Continuous<br />

Delivery Valve<br />

Box for Normal<br />

Pressure<br />

(sold separately)<br />

The <strong>Pump</strong> 33 Dual Syringe <strong>Pump</strong> is the only <strong>Harvard</strong><br />

<strong>Apparatus</strong> pump that has 2 independent motors. It is like<br />

having 2 pumps one chassis. Both motors can infuse,<br />

withdraw or infuse and withdraw simultaneously. With the<br />

addition of a valve this pump can infusion continuously 24<br />

hours a day, 7 days a week, 365 days a year.<br />

See page A11 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />

Line Catalog.<br />

PHD 22/2000 Push/Pull<br />

Syringe <strong>Pump</strong><br />

The <strong>Harvard</strong> PHD 22/2000 Advanced Syringe <strong>Pump</strong><br />

family is the most versatile of the pump lines. This pump is<br />

available for infusion only or infuse/withdraw models. This is<br />

the only pump that is available in a Push/Pull configuration.<br />

The pump can simultaneously infuse and withdraw the exact<br />

amount. Use this pump when you do not want the volume<br />

infused to alter pressure. With the addition of the 61-0270<br />

Tubing Segment, it can provide continuous flow. All<br />

PHD 22/2000 pumps have RS-232 communications capabilities.<br />

Specialized PHD 22/2000 pumps are programmable directly<br />

from the keypad.<br />

See pages A12 to A15 the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />

Full Line Catalog.<br />

61-0270<br />

Continuous Flow<br />

Tubing Segment<br />

(sold separately)<br />

<strong>Harvard</strong> Pulsatile Blood <strong>Pump</strong><br />

Simulates Cardiac Function!<br />

If you are performing cardiovascular<br />

work, this is the<br />

pump for you. It truly simulates<br />

the pumping action of<br />

the heart. It features silicone<br />

rubber-covered heart-type<br />

ball valves and smooth flow<br />

paths which minimize hemolysis.<br />

Only inert materials like<br />

silicone rubber, acrylic plastic,<br />

and Teflon ® contact the fluid. The pumping head is easy to<br />

take apart and reassemble and can be sterilized.<br />

See page A37 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog<br />

24/7 Sentry…To Monitor Your<br />

Equipment That is Unattended<br />

Sensaphone ® allows<br />

you to monitor your<br />

equipment while it is<br />

unattended. This<br />

<strong>Harvard</strong> <strong>Apparatus</strong><br />

unit can monitor 24/7<br />

and if it senses a<br />

problem it will automatically<br />

e-mail, telephone, or fax you anywhere in the world.<br />

See page A22 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs PAGE 2<br />

www.harvardapparatus.com • 508.893.8999


Enhancing Your Bioresearch<br />

Volume 2, Series 55<br />

Breakthroughs<br />

What’s NEW In Innovative Products For Bioresearch...<br />

www.harvardapparatus.com • 508.893.8999 Since 1901<br />

<strong>Harvard</strong> <strong>Apparatus</strong><br />

Peristaltic <strong>Pump</strong>s<br />

PERISTALTIC PUMPS<br />

Model 720 Compact<br />

Peristaltic <strong>Pump</strong>s<br />

<strong>Harvard</strong> MPII<br />

Mini-Peristaltic <strong>Pump</strong><br />

Peristaltic <strong>Pump</strong>s<br />

66 and 77<br />

Model 720 Compact<br />

Peristaltic <strong>Pump</strong><br />

70-2027 <strong>Harvard</strong> MPII<br />

Mini-Peristaltic <strong>Pump</strong><br />

The <strong>Harvard</strong> <strong>Apparatus</strong><br />

66 and 77 Peristaltic <strong>Pump</strong>s<br />

provide highly accurate and<br />

repeatable flow rates and<br />

are extremely easy to use.<br />

These pumps have the<br />

same high quality microstepping<br />

motor that creates<br />

the legendary accuracy of<br />

<strong>Harvard</strong> <strong>Apparatus</strong> Syringe<br />

<strong>Pump</strong>s. Other peristaltic<br />

FEATURES<br />

• Highly accurate<br />

peristaltic pumps ±1%<br />

• Unique ramped<br />

deceleration and<br />

‘slurp back’<br />

• Continuous volume or<br />

batch mode operation<br />

pumps have less accurate DC motors. No other peristaltic<br />

pump offers this quality of basic motor control. Additional<br />

accuracy features include ramped deceleration as the endpoint<br />

is approached and a ‘slurping’ feature to prevent end of<br />

dispense dripping. As the end-point approaches, the pump<br />

slows to drop-by-drop delivery. As the last drop required is<br />

delivered, the pump immediately reverses one step and slurps<br />

back preventing unintended fluid delivery. Only these<br />

<strong>Harvard</strong> <strong>Apparatus</strong> innovations enable accuracy approaching<br />

that of a syringe pump from a peristaltic pump.<br />

See page A43 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

The Model 720<br />

Compact Peristaltic <strong>Pump</strong><br />

is a stand-alone pump series<br />

with flow rates of 0.02 to<br />

15 ml/hr (Low Flow), 0.2 to<br />

180 ml/hr (Mid-Flow) and<br />

2 to 1800 ml/hr (High<br />

Flow). It is an ideal pump<br />

for applications which<br />

require limited size or<br />

weight, low EMI interference,<br />

the versatility of single<br />

FEATURES<br />

• Continuous infusion<br />

• Battery back-up (30 hrs)<br />

• Compact pump<br />

• Minimal electromagnetic<br />

radiation<br />

• Choose from low, mid,<br />

or high flow models<br />

and dual tube sets and/or external analog control.<br />

They measure only 2 1 ⁄2 x 2 1 ⁄4 x 4 inches!<br />

See page A42 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

Simplicity and Economy!<br />

The <strong>Harvard</strong> MPII Mini-Peristaltic <strong>Pump</strong> takes only one<br />

size of tubing, 1.6 mm ID x 3.2 mm OD (1/16 x 1/8 in). It can<br />

be used with either a single tube or two tubes simultaneously.<br />

Two front panel controls provide flow rates from approximately<br />

0.8 to 12.25 ml/min. The control knob provides<br />

variable adjustment from 0 to 100% of the selected flow rate<br />

range. The second control is a two position toggle switch<br />

marked x1, x2 which selects low or high flow rates.<br />

See page A42 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

NEW<br />

FEATURES<br />

Plastic Syringes<br />

Sterile Syringes<br />

without Needles<br />

SoloCath Catheters<br />

• Most thromboresistant<br />

material<br />

• Rounded distal tip is less<br />

traumatic to intimal<br />

lining of blood vessels<br />

We offer a full<br />

range of silicone,<br />

polyurethane and<br />

heparin coated<br />

polyurethane<br />

catheters in sizes<br />

for all species. With<br />

nearly 20 years of<br />

experience designing<br />

and manufacturing<br />

laboratory animal catheters,<br />

we can help you choose the<br />

the ideal catheter for your<br />

application.<br />

See pages B33 and B34 in the<br />

2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />

Full Line Catalog.<br />

Non-Sterile Syringes<br />

without Needles<br />

These Monoject ® Plastic Syringes can be used for any<br />

laboratory application. They are without needles and are<br />

available in either boxes or cases.<br />

See page A77 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

ACCESSORIES<br />

NEW<br />

200 ml<br />

100 ml<br />

50 ml<br />

20 ml<br />

Glass Syringes<br />

Stainless Steel Syringes<br />

<strong>Harvard</strong> High Pressure<br />

Stainless Steel Syringes<br />

2.5 ml<br />

1<br />

⁄8 inch or 1 ⁄4 inch SWAGELOK ® tip.<br />

Introducing our<br />

NEW 2.5 ml stainless<br />

steel syringe.<br />

These syringes are<br />

designed to utilize<br />

the high forces available<br />

in our syringe<br />

pumps. The syringes<br />

are constructed<br />

entirely of #316<br />

stainless steel. Select<br />

from either a 1 ⁄16 inch,<br />

Now we offer syringes from 200 ml all the way down to<br />

2.5 ml to produce pressures up to 7500 psi.<br />

See page A70 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

These standard Glass Syringes are available with Luer Lock,<br />

Luer tip and removable needle terminations.<br />

8 ml<br />

See pages A72 and A74 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />

Line Catalog.<br />

Luer to Tube Connection Kits<br />

72-1406 Luer Connector Kit,<br />

White Nylon<br />

Three kit styles are available. The uer connection kits contain<br />

a selection of Luer fittings to interconnect Luer connectors (e.g.<br />

syringes, stopcocks and needles) with one another and with tubing.<br />

See page A89 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />

Tygon ® Laboratory Tubing (R-3603)<br />

The most consistently<br />

reliable tubing<br />

for the transfer of<br />

liquids and gases is Tygon ® Laboratory Tubing. It handles<br />

virtually all inorganic chemicals found in today’s laboratories.<br />

It is crystal-clear, flexible, non-oxidizing and non-contaminating.<br />

Tygon ® Laboratory Tubing is long lasting, crack resistant<br />

and is less permeable than rubber tubing. The glassy-smooth<br />

inner bore helps prevent buildup so that cleaning is facilitated.<br />

Coils are marked at 1-foot intervals for easy measuring.<br />

Autoclavable. Remains flexible at -45°F (-43°C). Durometer<br />

hardness: Shore A, 55.<br />

See pages A78 to A82 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />

Line Catalog.<br />

P AGE 3<br />

<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs www.harvardapparatus.com • 508.893.8999


Enhancing Your Bioresearch<br />

Volume 2, Series 55<br />

Breakthroughs<br />

What’s NEW In Innovative Products For Bioresearch...<br />

www.harvardapparatus.com • 508.893.8999 Since 1901<br />

CROSSWORD PUZZLE #2<br />

Across<br />

2. Technotronic hit.<br />

Down<br />

1. Governator.<br />

1 2<br />

3 4<br />

5<br />

6. Transcription mutation.<br />

3. Neonatal rat.<br />

6<br />

7. Type of injection.<br />

4. Blood pump.<br />

7<br />

8<br />

8. Latin gold.<br />

9. Not appendicular.<br />

10. <strong>Pump</strong>ing plasma from blood.<br />

11. Particle (He++).<br />

13. Matter phase.<br />

14. Some docs are these.<br />

15. Pyrethrins source.<br />

16. World’s fair.<br />

17. Some docs are these.<br />

18. <strong>Pump</strong> usu. behind serpentine belt.<br />

22. Some docs are these.<br />

24. 273.15 Deg Kelvin and 760 torr.<br />

26. Air pump.<br />

5. Tank with an air pump.<br />

7. Fluid influx.<br />

9. Vet org.<br />

12. Drug candidate profile screening<br />

(abbr.).<br />

18. DNA daddy.<br />

19. Another model mammal.<br />

20. Venom pump.<br />

21. LXWXH.<br />

23. DNA daddy.<br />

25. Mortar partner.<br />

27. Analogous to United States<br />

Pharmacopeia unit (USP).<br />

11<br />

14<br />

21<br />

26<br />

22<br />

9<br />

20<br />

17<br />

10<br />

16<br />

23<br />

13<br />

27<br />

12<br />

15<br />

18 19<br />

24<br />

25<br />

27. 1D pumps this.<br />

28. Bacterial count.<br />

29. A model mammal.<br />

30. <strong>Pump</strong> up.<br />

29<br />

28<br />

30<br />

For answers visit us at:<br />

www.harv ardapparatus.com<br />

CONTACT<br />

PUMP APPLICATION GUIDE<br />

Application<br />

Best <strong>Pump</strong> for the Job<br />

84 October Hill Road, Holliston, MA 01746, USA<br />

Phone: 508.893.8999 Toll-Free: 800.272.2775 (USA only) Fax: 508.429.5732<br />

E-Mail: bioscience@harvardapparatus.com<br />

Web: www.harvardapparatus.com<br />

<strong>Harvard</strong> <strong>Apparatus</strong> Ltd. – United Kingdom<br />

Fircroft Way<br />

Edenbridge, Kent, TN8 6HE, United Kingdom<br />

Phone: (44) 1732 864001<br />

Fax: (44) 1732 863356<br />

E-Mail: sales@harvardapparatus.co.uk<br />

Web:<br />

www.harvardapparatus.co.uk<br />

<strong>Harvard</strong> <strong>Apparatus</strong> – Canada<br />

6010 Vanden Abeele<br />

Saint Laurent, Quebec, H4S 1R9, Canada<br />

Phone: 514.335.0792<br />

Toll-Free: 800.361.1905 (Canada only)<br />

Fax: 514.335.3482<br />

Toll-Free Fax: 800.335.0792 (Canada only)<br />

E-Mail: sales@harvardapparatus.ca<br />

Web:<br />

www.harvardapparatus.ca<br />

<strong>Harvard</strong> <strong>Apparatus</strong> S.A.R.L. – France<br />

6 Avenue des Andes<br />

Miniparc Bat. 8<br />

Les Ulis Cedex, F-91952, France<br />

Phone: (33) 1.64.46.00.85<br />

Fax: (33) 1.64.46.94.38<br />

E-Mail: info@harvardapparatus.fr<br />

• Bulk Fluid Transfer <strong>Pump</strong>ing ..........................................Peristaltic (66 and 77) <strong>Pump</strong>s<br />

• Cellular Injection ............................................................<strong>Pump</strong> 11 Pico Plus, PHD <strong>Pump</strong>s<br />

• Constant <strong>Pump</strong>ing............................................................Push Pull, <strong>Pump</strong> 33, Peristaltic <strong>Pump</strong>s<br />

• Drug Delivery ..................................................................Nanomite, <strong>Pump</strong> 11 Pico Plus, PHD <strong>Pump</strong>s<br />

• Fluid Injection..................................................................PHD High Pressure <strong>Pump</strong>s<br />

• Food Delivery ..................................................................10 Syringe Feeding Station, PHD <strong>Pump</strong>s<br />

• Heart Simulator ..............................................................Pulsatile Blood <strong>Pump</strong><br />

• High Pressure <strong>Pump</strong>ing ..................................................PHD <strong>Pump</strong>s<br />

• Infusions ..........................................................................All PHD <strong>Pump</strong>s, <strong>Pump</strong> 11 <strong>Pump</strong>s<br />

• Liquid Chromatography ..................................................PHD 22/2000, <strong>Pump</strong> 11 Plus<br />

• Mass Spectroscopy ..........................................................<strong>Pump</strong> 11 Pico Plus, PHD 22/2000 with Microliter<br />

Syringe Rack and <strong>Pump</strong> 22<br />

• Microdialysis....................................................................<strong>Pump</strong> 11 Pico Plus, PHD <strong>Pump</strong>s<br />

• Micro-Injection ................................................................Nanomite, <strong>Pump</strong> 11 Pico Plus<br />

• Multi-Syringe ..................................................................2 Syringe <strong>Pump</strong>s, PHD <strong>Pump</strong>s with 6 to 10<br />

Syringe Holders, PHD with 4 Syringe Holder<br />

• Perfusion..........................................................................Peristaltic <strong>Pump</strong>s, Blood <strong>Pump</strong>s<br />

• Peristaltic ........................................................................<strong>Pump</strong> 66, <strong>Pump</strong> 77, MP II Peristaltic <strong>Pump</strong><br />

Hugo Sachs Elektronik – Germany<br />

<strong>Harvard</strong> <strong>Apparatus</strong> GmbH<br />

Gruenstrasse 1<br />

March – Hugstetten, D-79232, Germany<br />

Phone: (49) 7665.9200.0<br />

Fax: (49) 7665.9200.90<br />

E-Mail: info@hugo-sachs.de<br />

Web:<br />

www.hugo-sachs.de<br />

Take-In Incorporated – Japan<br />

Kyosu Bldg. 3-31-11<br />

Amanuma Suginami, Tokyo 167-0032, Japan<br />

Phone: (81) 3.3597.1911<br />

Fax: (81) 3.5833.5596<br />

E-Mail: info@ha-j.com<br />

Web:<br />

www.ha-j.com<br />

General Applications<br />

• The injection of dyes, perfumes and flavorings<br />

in industrial applications.<br />

• Applications with liquids or viscous materials in<br />

micromanufacturing.<br />

• Continuous injections of reactants into reactor<br />

vessels.<br />

General Applications<br />

• Simultaneous samplings from two sites.<br />

• Injecting fluids in nanotechnology channels.<br />

• Continuous injection for long term<br />

toxicology testing.<br />

<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs PAGE 4<br />

www.harvardapparatus.com • 508.893.8999