Pump Edition - Harvard Apparatus
Pump Edition - Harvard Apparatus
Pump Edition - Harvard Apparatus
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Enhancing Your Bioresearch<br />
Breakthroughs<br />
What’s NEW In Innovative Products For Bioresearch...<br />
Volume 2, Series 55<br />
www.harvardapparatus.com • 508.893.8999 Since 1901<br />
SPECIAL PUMP EDITION<br />
NEW<br />
MRI Compatible <strong>Pump</strong><br />
NEW<br />
Physio 22 Low RFI <strong>Pump</strong><br />
High Pressure Syringe <strong>Pump</strong><br />
PHD 22/2000 Hpsi<br />
MRI Compatible Syringe <strong>Pump</strong> Meets the<br />
Needs of the MRI Environment<br />
Constructed of non-ferromagnetic<br />
metals! Ideal for<br />
drug delivery and tracer<br />
studies!<br />
Bring pumping action as<br />
close as 2-3 feet from the<br />
magnet. The Run/Stop<br />
switch on the syringe pump<br />
head lets you control pump<br />
functions, standing next to<br />
the MRI.<br />
FEATURES<br />
• Programmability<br />
• Pulseless Flow<br />
• High precision<br />
(±0.35%)<br />
• High reproducibility<br />
• High linear force<br />
(66 lbs)<br />
Please visit us at www.harvardapparatus.com for specifications.<br />
Low EMI Syringe <strong>Pump</strong>s For Perfusing<br />
Near Sensitive Physiological Sensors<br />
Now the PHD 22/2000 Series and the Physio 22 Syringe<br />
<strong>Pump</strong>s have virtually no electrical noise emitted so that they<br />
can be used in close proximity to sensitive sensors without<br />
causing any noise interference. This feature is ideal for cell<br />
physiology experiments.<br />
See pages A31 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />
Line Catalog.<br />
The <strong>Harvard</strong> PHD 22/2000<br />
Hpsi pump is a specialized<br />
pump that provides high pressure<br />
and high volume flow.<br />
It was designed to hold the<br />
<strong>Harvard</strong> Stainless Steel<br />
syringes. It provides up to<br />
433 pounds of pumping<br />
force. A single 200 milliliter<br />
stainless steel syringe can<br />
provide a flow rate up to<br />
112 milliliters/minute! Gang<br />
the output of 4 syringes and<br />
that value quadruples. The<br />
pump is a remote model<br />
PHD 4400 Hpsi<br />
FEATURES<br />
PHD 4400 Hpsi<br />
• Delivers >200 lbs<br />
(91 kg) linear pumping<br />
force across a wide<br />
flow rate range<br />
• Accurate and smooth flow<br />
• Ideally suited for<br />
stainless steel syringes<br />
where the control box is separated from the pumping mechanism<br />
by a 152 cm (60 in) cable. A longer cable is also available<br />
should your application require it.<br />
See pages A16 and A18 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />
Full Line Catalog.<br />
MASS SPEC PUMPS<br />
`<br />
NEW<br />
Nanomite Micro Injector<br />
<strong>Pump</strong><br />
Standard Infuse/Withdraw <strong>Pump</strong><br />
11 Pico Plus Syringe <strong>Pump</strong><br />
Versatile PHD 22/2000 Advanced<br />
Syringe <strong>Pump</strong>s<br />
Preserve Precious Materials.<br />
Direct Inject! No Compliance Issues!<br />
The new Nanomite Micro<br />
Injector <strong>Pump</strong> is a miniature<br />
precision pump which allows<br />
accurate injection of the<br />
smallest of volumes, even to<br />
nanoliter ranges. It combines<br />
an injector pump head and<br />
the body of <strong>Harvard</strong><br />
<strong>Apparatus</strong> <strong>Pump</strong> 11 Syringe<br />
<strong>Pump</strong>. New safety features<br />
and microstepping make it<br />
the perfect pump for<br />
DIRECT microinjections in<br />
tight places.<br />
Please visit us at<br />
www.harvardapparatus.com for<br />
specifications.<br />
7 1 ⁄4"<br />
FEATURES<br />
• The linear force to handle<br />
gas tight syringes<br />
• A new Volume Dispense<br />
Alarm when dispensing<br />
is complete<br />
• Safeguard Alarm chimes<br />
when pumping stops<br />
• BrightBlue LED Run<br />
Indicator<br />
• QuickFill for Fast-Infuse<br />
and Fast-Withdraw<br />
• Flow range in picoliters,<br />
nanoliters or microliters!<br />
Lowest Flow Rates!<br />
The <strong>Pump</strong> 11 Pico Plus is the lowest flow rate pump that<br />
<strong>Harvard</strong> <strong>Apparatus</strong> manufactures. It can accurately deliver<br />
volumes down to 3.3 picoliters/minute. It is ideal for<br />
applications such as cellular injections or for providing the micro<br />
flow required for FIA or capillary LC. It has both infusion and<br />
withdrawal capabilities as well as RS-232 communications.<br />
See page A9 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
The <strong>Harvard</strong> PHD<br />
22/2000 Advanced<br />
Syringe <strong>Pump</strong> family is<br />
the most versatile of the<br />
pump lines. This pump<br />
is available for infusion<br />
only or infuse/withdraw<br />
models. This is the only<br />
pump that is available<br />
PHD 22/2000 with Microliter Rack in a Push/Pull configuration.<br />
All PHD pumps<br />
have RS-232 communications capabilities. Specialized<br />
PHD 22/2000 models are programmable directly from the<br />
keypad. In addition, a multitude of syringe racks are available<br />
to hold 2, 4 or up to 10 syringes. A microliter syringe rack is<br />
also available for microliter applications. Remote versions are<br />
available where the control box and pumping mechanism are<br />
separated by a 9.1 meter (30 foot) cable.<br />
See pages A12 to A15 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />
Full Line Catalog.<br />
P AGE 1<br />
<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs www.harvardapparatus.com • 508.893.8999
Enhancing Your Bioresearch<br />
Volume 2, Series 55<br />
Breakthroughs<br />
What’s NEW In Innovative Products For Bioresearch...<br />
www.harvardapparatus.com • 508.893.8999 Since 1901<br />
NEW<br />
Nanomite Micro<br />
Injection <strong>Pump</strong><br />
REMOTE PUMPS<br />
Remote, Infuse/Withdraw &<br />
Programmable High Pressure<br />
PHD Syringe <strong>Pump</strong>s<br />
COMPUTER<br />
CONTROL<br />
LabView Drivers - Take Control<br />
of Your Syringe <strong>Pump</strong>s<br />
7 3 ⁄4"<br />
Injector<br />
Head<br />
Measures<br />
Only 7 3 ⁄4"!<br />
PHD 22/2000 Remote<br />
Control with 6/10 Multi-Rack<br />
FREE!<br />
The new Nanomite<br />
Micro Injector <strong>Pump</strong> is a<br />
miniature precision pump<br />
which allows accurate<br />
injection of the smallest of<br />
volumes, even to nanoliter<br />
ranges. It combines an<br />
injector pump head and the<br />
body of <strong>Harvard</strong> <strong>Apparatus</strong><br />
<strong>Pump</strong> 11 Syringe <strong>Pump</strong>.<br />
New safety features and<br />
microstepping make it the<br />
perfect pump for DIRECT<br />
microinjections in tight<br />
places.<br />
Please visit us at<br />
www.harvardapparatus.com for<br />
complete details.<br />
FEATURES<br />
• Micro-inject small fluid<br />
volumes precisely.<br />
• Five pounds of pumping<br />
force!<br />
• BrightBlue LED run<br />
light indicator.<br />
• Perfect for space limited<br />
applications.<br />
• End-of-Run and safety<br />
alarms.<br />
• Six foot cable allows<br />
safe operation and<br />
injection in a sterile<br />
hood, or from behind<br />
a barrier<br />
Standard Infuse/Withdraw<br />
<strong>Harvard</strong> 33 Dual Syringe <strong>Pump</strong><br />
Every version of the<br />
PHD 22/2000 <strong>Pump</strong> is now<br />
available with a stronger<br />
motor that can provide more<br />
force. These pumps are<br />
ideal when working with<br />
viscous fluid or when driving<br />
multiple syringes. The<br />
standard force PHD<br />
22/2000 series syringe<br />
pump delivers an average nominal force of 50 lbs. while the<br />
high power version delivers 66 lbs of linear force. If you<br />
require even greater force see the PHD 22/2000 Hpsi or the<br />
<strong>Pump</strong> 4400 Hpsi.<br />
See pages A12 to A15 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />
Line Catalog.<br />
CONTINUOUS FLOW<br />
FEATURES<br />
• High accuracy and<br />
precision.<br />
• Low flow rate.<br />
• Ultimate flexibility<br />
and versatility.<br />
• 2 year warranty.<br />
<strong>Harvard</strong> PHD 22/2000 Push/Pull<br />
Syringe <strong>Pump</strong><br />
LabVIEW Drivers<br />
for <strong>Harvard</strong> <strong>Apparatus</strong><br />
PHD 22/2000 and<br />
model 11 Syringe<br />
<strong>Pump</strong>s is built using the<br />
popular LabVIEW <br />
programming application from National Instruments. Control<br />
many pumps, write special applications or integrate into existing<br />
applications. Contact <strong>Harvard</strong> <strong>Apparatus</strong> to get your free copy.<br />
See page A21 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog<br />
SPECIALTY<br />
PUMPS<br />
10-Syringe Feeding System <strong>Pump</strong><br />
This 10-Syringe<br />
Feeding System is a<br />
convenient and<br />
versatile system providing<br />
a method to feed<br />
multiple animals simultaneously,<br />
making it<br />
ideal for multiple animal<br />
feeding studies or other applications which require precise<br />
parallel pumping. The standard syringe rack can hold up<br />
to 10 syringes ranging in size from 50cc to 140cc.<br />
See page A32 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog<br />
33 Dual Syringe <strong>Pump</strong><br />
Continuous Infusion 24 hours a day,<br />
7 days a week, 365 days a year!<br />
Continuous<br />
Delivery Valve<br />
Box for Normal<br />
Pressure<br />
(sold separately)<br />
The <strong>Pump</strong> 33 Dual Syringe <strong>Pump</strong> is the only <strong>Harvard</strong><br />
<strong>Apparatus</strong> pump that has 2 independent motors. It is like<br />
having 2 pumps one chassis. Both motors can infuse,<br />
withdraw or infuse and withdraw simultaneously. With the<br />
addition of a valve this pump can infusion continuously 24<br />
hours a day, 7 days a week, 365 days a year.<br />
See page A11 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />
Line Catalog.<br />
PHD 22/2000 Push/Pull<br />
Syringe <strong>Pump</strong><br />
The <strong>Harvard</strong> PHD 22/2000 Advanced Syringe <strong>Pump</strong><br />
family is the most versatile of the pump lines. This pump is<br />
available for infusion only or infuse/withdraw models. This is<br />
the only pump that is available in a Push/Pull configuration.<br />
The pump can simultaneously infuse and withdraw the exact<br />
amount. Use this pump when you do not want the volume<br />
infused to alter pressure. With the addition of the 61-0270<br />
Tubing Segment, it can provide continuous flow. All<br />
PHD 22/2000 pumps have RS-232 communications capabilities.<br />
Specialized PHD 22/2000 pumps are programmable directly<br />
from the keypad.<br />
See pages A12 to A15 the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />
Full Line Catalog.<br />
61-0270<br />
Continuous Flow<br />
Tubing Segment<br />
(sold separately)<br />
<strong>Harvard</strong> Pulsatile Blood <strong>Pump</strong><br />
Simulates Cardiac Function!<br />
If you are performing cardiovascular<br />
work, this is the<br />
pump for you. It truly simulates<br />
the pumping action of<br />
the heart. It features silicone<br />
rubber-covered heart-type<br />
ball valves and smooth flow<br />
paths which minimize hemolysis.<br />
Only inert materials like<br />
silicone rubber, acrylic plastic,<br />
and Teflon ® contact the fluid. The pumping head is easy to<br />
take apart and reassemble and can be sterilized.<br />
See page A37 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog<br />
24/7 Sentry…To Monitor Your<br />
Equipment That is Unattended<br />
Sensaphone ® allows<br />
you to monitor your<br />
equipment while it is<br />
unattended. This<br />
<strong>Harvard</strong> <strong>Apparatus</strong><br />
unit can monitor 24/7<br />
and if it senses a<br />
problem it will automatically<br />
e-mail, telephone, or fax you anywhere in the world.<br />
See page A22 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs PAGE 2<br />
www.harvardapparatus.com • 508.893.8999
Enhancing Your Bioresearch<br />
Volume 2, Series 55<br />
Breakthroughs<br />
What’s NEW In Innovative Products For Bioresearch...<br />
www.harvardapparatus.com • 508.893.8999 Since 1901<br />
<strong>Harvard</strong> <strong>Apparatus</strong><br />
Peristaltic <strong>Pump</strong>s<br />
PERISTALTIC PUMPS<br />
Model 720 Compact<br />
Peristaltic <strong>Pump</strong>s<br />
<strong>Harvard</strong> MPII<br />
Mini-Peristaltic <strong>Pump</strong><br />
Peristaltic <strong>Pump</strong>s<br />
66 and 77<br />
Model 720 Compact<br />
Peristaltic <strong>Pump</strong><br />
70-2027 <strong>Harvard</strong> MPII<br />
Mini-Peristaltic <strong>Pump</strong><br />
The <strong>Harvard</strong> <strong>Apparatus</strong><br />
66 and 77 Peristaltic <strong>Pump</strong>s<br />
provide highly accurate and<br />
repeatable flow rates and<br />
are extremely easy to use.<br />
These pumps have the<br />
same high quality microstepping<br />
motor that creates<br />
the legendary accuracy of<br />
<strong>Harvard</strong> <strong>Apparatus</strong> Syringe<br />
<strong>Pump</strong>s. Other peristaltic<br />
FEATURES<br />
• Highly accurate<br />
peristaltic pumps ±1%<br />
• Unique ramped<br />
deceleration and<br />
‘slurp back’<br />
• Continuous volume or<br />
batch mode operation<br />
pumps have less accurate DC motors. No other peristaltic<br />
pump offers this quality of basic motor control. Additional<br />
accuracy features include ramped deceleration as the endpoint<br />
is approached and a ‘slurping’ feature to prevent end of<br />
dispense dripping. As the end-point approaches, the pump<br />
slows to drop-by-drop delivery. As the last drop required is<br />
delivered, the pump immediately reverses one step and slurps<br />
back preventing unintended fluid delivery. Only these<br />
<strong>Harvard</strong> <strong>Apparatus</strong> innovations enable accuracy approaching<br />
that of a syringe pump from a peristaltic pump.<br />
See page A43 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
The Model 720<br />
Compact Peristaltic <strong>Pump</strong><br />
is a stand-alone pump series<br />
with flow rates of 0.02 to<br />
15 ml/hr (Low Flow), 0.2 to<br />
180 ml/hr (Mid-Flow) and<br />
2 to 1800 ml/hr (High<br />
Flow). It is an ideal pump<br />
for applications which<br />
require limited size or<br />
weight, low EMI interference,<br />
the versatility of single<br />
FEATURES<br />
• Continuous infusion<br />
• Battery back-up (30 hrs)<br />
• Compact pump<br />
• Minimal electromagnetic<br />
radiation<br />
• Choose from low, mid,<br />
or high flow models<br />
and dual tube sets and/or external analog control.<br />
They measure only 2 1 ⁄2 x 2 1 ⁄4 x 4 inches!<br />
See page A42 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
Simplicity and Economy!<br />
The <strong>Harvard</strong> MPII Mini-Peristaltic <strong>Pump</strong> takes only one<br />
size of tubing, 1.6 mm ID x 3.2 mm OD (1/16 x 1/8 in). It can<br />
be used with either a single tube or two tubes simultaneously.<br />
Two front panel controls provide flow rates from approximately<br />
0.8 to 12.25 ml/min. The control knob provides<br />
variable adjustment from 0 to 100% of the selected flow rate<br />
range. The second control is a two position toggle switch<br />
marked x1, x2 which selects low or high flow rates.<br />
See page A42 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
NEW<br />
FEATURES<br />
Plastic Syringes<br />
Sterile Syringes<br />
without Needles<br />
SoloCath Catheters<br />
• Most thromboresistant<br />
material<br />
• Rounded distal tip is less<br />
traumatic to intimal<br />
lining of blood vessels<br />
We offer a full<br />
range of silicone,<br />
polyurethane and<br />
heparin coated<br />
polyurethane<br />
catheters in sizes<br />
for all species. With<br />
nearly 20 years of<br />
experience designing<br />
and manufacturing<br />
laboratory animal catheters,<br />
we can help you choose the<br />
the ideal catheter for your<br />
application.<br />
See pages B33 and B34 in the<br />
2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong><br />
Full Line Catalog.<br />
Non-Sterile Syringes<br />
without Needles<br />
These Monoject ® Plastic Syringes can be used for any<br />
laboratory application. They are without needles and are<br />
available in either boxes or cases.<br />
See page A77 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
ACCESSORIES<br />
NEW<br />
200 ml<br />
100 ml<br />
50 ml<br />
20 ml<br />
Glass Syringes<br />
Stainless Steel Syringes<br />
<strong>Harvard</strong> High Pressure<br />
Stainless Steel Syringes<br />
2.5 ml<br />
1<br />
⁄8 inch or 1 ⁄4 inch SWAGELOK ® tip.<br />
Introducing our<br />
NEW 2.5 ml stainless<br />
steel syringe.<br />
These syringes are<br />
designed to utilize<br />
the high forces available<br />
in our syringe<br />
pumps. The syringes<br />
are constructed<br />
entirely of #316<br />
stainless steel. Select<br />
from either a 1 ⁄16 inch,<br />
Now we offer syringes from 200 ml all the way down to<br />
2.5 ml to produce pressures up to 7500 psi.<br />
See page A70 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
These standard Glass Syringes are available with Luer Lock,<br />
Luer tip and removable needle terminations.<br />
8 ml<br />
See pages A72 and A74 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />
Line Catalog.<br />
Luer to Tube Connection Kits<br />
72-1406 Luer Connector Kit,<br />
White Nylon<br />
Three kit styles are available. The uer connection kits contain<br />
a selection of Luer fittings to interconnect Luer connectors (e.g.<br />
syringes, stopcocks and needles) with one another and with tubing.<br />
See page A89 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full Line Catalog.<br />
Tygon ® Laboratory Tubing (R-3603)<br />
The most consistently<br />
reliable tubing<br />
for the transfer of<br />
liquids and gases is Tygon ® Laboratory Tubing. It handles<br />
virtually all inorganic chemicals found in today’s laboratories.<br />
It is crystal-clear, flexible, non-oxidizing and non-contaminating.<br />
Tygon ® Laboratory Tubing is long lasting, crack resistant<br />
and is less permeable than rubber tubing. The glassy-smooth<br />
inner bore helps prevent buildup so that cleaning is facilitated.<br />
Coils are marked at 1-foot intervals for easy measuring.<br />
Autoclavable. Remains flexible at -45°F (-43°C). Durometer<br />
hardness: Shore A, 55.<br />
See pages A78 to A82 in the 2004/2005 <strong>Harvard</strong> <strong>Apparatus</strong> Full<br />
Line Catalog.<br />
P AGE 3<br />
<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs www.harvardapparatus.com • 508.893.8999
Enhancing Your Bioresearch<br />
Volume 2, Series 55<br />
Breakthroughs<br />
What’s NEW In Innovative Products For Bioresearch...<br />
www.harvardapparatus.com • 508.893.8999 Since 1901<br />
CROSSWORD PUZZLE #2<br />
Across<br />
2. Technotronic hit.<br />
Down<br />
1. Governator.<br />
1 2<br />
3 4<br />
5<br />
6. Transcription mutation.<br />
3. Neonatal rat.<br />
6<br />
7. Type of injection.<br />
4. Blood pump.<br />
7<br />
8<br />
8. Latin gold.<br />
9. Not appendicular.<br />
10. <strong>Pump</strong>ing plasma from blood.<br />
11. Particle (He++).<br />
13. Matter phase.<br />
14. Some docs are these.<br />
15. Pyrethrins source.<br />
16. World’s fair.<br />
17. Some docs are these.<br />
18. <strong>Pump</strong> usu. behind serpentine belt.<br />
22. Some docs are these.<br />
24. 273.15 Deg Kelvin and 760 torr.<br />
26. Air pump.<br />
5. Tank with an air pump.<br />
7. Fluid influx.<br />
9. Vet org.<br />
12. Drug candidate profile screening<br />
(abbr.).<br />
18. DNA daddy.<br />
19. Another model mammal.<br />
20. Venom pump.<br />
21. LXWXH.<br />
23. DNA daddy.<br />
25. Mortar partner.<br />
27. Analogous to United States<br />
Pharmacopeia unit (USP).<br />
11<br />
14<br />
21<br />
26<br />
22<br />
9<br />
20<br />
17<br />
10<br />
16<br />
23<br />
13<br />
27<br />
12<br />
15<br />
18 19<br />
24<br />
25<br />
27. 1D pumps this.<br />
28. Bacterial count.<br />
29. A model mammal.<br />
30. <strong>Pump</strong> up.<br />
29<br />
28<br />
30<br />
For answers visit us at:<br />
www.harv ardapparatus.com<br />
CONTACT<br />
PUMP APPLICATION GUIDE<br />
Application<br />
Best <strong>Pump</strong> for the Job<br />
84 October Hill Road, Holliston, MA 01746, USA<br />
Phone: 508.893.8999 Toll-Free: 800.272.2775 (USA only) Fax: 508.429.5732<br />
E-Mail: bioscience@harvardapparatus.com<br />
Web: www.harvardapparatus.com<br />
<strong>Harvard</strong> <strong>Apparatus</strong> Ltd. – United Kingdom<br />
Fircroft Way<br />
Edenbridge, Kent, TN8 6HE, United Kingdom<br />
Phone: (44) 1732 864001<br />
Fax: (44) 1732 863356<br />
E-Mail: sales@harvardapparatus.co.uk<br />
Web:<br />
www.harvardapparatus.co.uk<br />
<strong>Harvard</strong> <strong>Apparatus</strong> – Canada<br />
6010 Vanden Abeele<br />
Saint Laurent, Quebec, H4S 1R9, Canada<br />
Phone: 514.335.0792<br />
Toll-Free: 800.361.1905 (Canada only)<br />
Fax: 514.335.3482<br />
Toll-Free Fax: 800.335.0792 (Canada only)<br />
E-Mail: sales@harvardapparatus.ca<br />
Web:<br />
www.harvardapparatus.ca<br />
<strong>Harvard</strong> <strong>Apparatus</strong> S.A.R.L. – France<br />
6 Avenue des Andes<br />
Miniparc Bat. 8<br />
Les Ulis Cedex, F-91952, France<br />
Phone: (33) 1.64.46.00.85<br />
Fax: (33) 1.64.46.94.38<br />
E-Mail: info@harvardapparatus.fr<br />
• Bulk Fluid Transfer <strong>Pump</strong>ing ..........................................Peristaltic (66 and 77) <strong>Pump</strong>s<br />
• Cellular Injection ............................................................<strong>Pump</strong> 11 Pico Plus, PHD <strong>Pump</strong>s<br />
• Constant <strong>Pump</strong>ing............................................................Push Pull, <strong>Pump</strong> 33, Peristaltic <strong>Pump</strong>s<br />
• Drug Delivery ..................................................................Nanomite, <strong>Pump</strong> 11 Pico Plus, PHD <strong>Pump</strong>s<br />
• Fluid Injection..................................................................PHD High Pressure <strong>Pump</strong>s<br />
• Food Delivery ..................................................................10 Syringe Feeding Station, PHD <strong>Pump</strong>s<br />
• Heart Simulator ..............................................................Pulsatile Blood <strong>Pump</strong><br />
• High Pressure <strong>Pump</strong>ing ..................................................PHD <strong>Pump</strong>s<br />
• Infusions ..........................................................................All PHD <strong>Pump</strong>s, <strong>Pump</strong> 11 <strong>Pump</strong>s<br />
• Liquid Chromatography ..................................................PHD 22/2000, <strong>Pump</strong> 11 Plus<br />
• Mass Spectroscopy ..........................................................<strong>Pump</strong> 11 Pico Plus, PHD 22/2000 with Microliter<br />
Syringe Rack and <strong>Pump</strong> 22<br />
• Microdialysis....................................................................<strong>Pump</strong> 11 Pico Plus, PHD <strong>Pump</strong>s<br />
• Micro-Injection ................................................................Nanomite, <strong>Pump</strong> 11 Pico Plus<br />
• Multi-Syringe ..................................................................2 Syringe <strong>Pump</strong>s, PHD <strong>Pump</strong>s with 6 to 10<br />
Syringe Holders, PHD with 4 Syringe Holder<br />
• Perfusion..........................................................................Peristaltic <strong>Pump</strong>s, Blood <strong>Pump</strong>s<br />
• Peristaltic ........................................................................<strong>Pump</strong> 66, <strong>Pump</strong> 77, MP II Peristaltic <strong>Pump</strong><br />
Hugo Sachs Elektronik – Germany<br />
<strong>Harvard</strong> <strong>Apparatus</strong> GmbH<br />
Gruenstrasse 1<br />
March – Hugstetten, D-79232, Germany<br />
Phone: (49) 7665.9200.0<br />
Fax: (49) 7665.9200.90<br />
E-Mail: info@hugo-sachs.de<br />
Web:<br />
www.hugo-sachs.de<br />
Take-In Incorporated – Japan<br />
Kyosu Bldg. 3-31-11<br />
Amanuma Suginami, Tokyo 167-0032, Japan<br />
Phone: (81) 3.3597.1911<br />
Fax: (81) 3.5833.5596<br />
E-Mail: info@ha-j.com<br />
Web:<br />
www.ha-j.com<br />
General Applications<br />
• The injection of dyes, perfumes and flavorings<br />
in industrial applications.<br />
• Applications with liquids or viscous materials in<br />
micromanufacturing.<br />
• Continuous injections of reactants into reactor<br />
vessels.<br />
General Applications<br />
• Simultaneous samplings from two sites.<br />
• Injecting fluids in nanotechnology channels.<br />
• Continuous injection for long term<br />
toxicology testing.<br />
<strong>Harvard</strong> <strong>Apparatus</strong> • Bio-Breakthroughs PAGE 4<br />
www.harvardapparatus.com • 508.893.8999