Door Handles, Locking and Security - Hafele
Door Handles, Locking and Security - Hafele Door Handles, Locking and Security - Hafele
Architectural Hardware Locking and Security DT Lite Residential Note • From out side the door can be opened by normal, privileged, Each set of article number consists of electronic front and rear toggled key cards or mechanical key during emergencies module, cover plate and striking plate. But It is not including • Automatic battery saving electronic mortise lock, cylinder and mounting screws. • Battery-life: At least 10,000 openings • Low battery alarm signal • Reading range: 0 – 40 mm • Stable reading RFID (Radio Frequency Identification) technology • Fast opening process • For door thickness: 40 – 65 mm C-Shaped handle J-Shaped handle Finish Right hand Left hand Chrome polished, PVD 917.80.362 917.80.352 Chrome matt, PVD 917.80.364 917.80.354 Brass polished, PVD 917.80.368 917.80.358 Brass matt, PVD 917.80.365 917.80.355 Finish Right hand Left hand Chrome polished, PVD 917.80.312 917.80.302 Chrome matt, PVD 917.80.314 917.80.304 Brass polished, PVD 917.80.318 917.80.308 Brass matt, PVD 917.80.315 917.80.305 We reserve the right to alter specifications without notice (HMA Basic 2011/12). Electronic mortise lock Version Cat. No. RH Inward Model 917.81.001 RH Outward Model 917.81.011 LH Inward Model 917.81.000 LH Outward Model 917.81.010 10 New products and systems: www.hafele.com HMA 10.49
Architectural Hardware Locking and Security Panic exit device Area of application: For rebated or flush, single or double, wooden or steel doors Suitable for: Fire resistant and smoke control doors Door width: 840 – 914 mm Door thickness: 43.9 – 50.8 mm Mounting: For DIN left and DIN right hand use Function Opening of door from inside: By pushing the touchbar Opening of door from outside (optional): By activating the lever handle. Key locks or unlocks lever handles (ANSI cipher bit function) Product components for single doors Inside: - 1 Touchbar Outside: - 1 Lever handle with round rosette Inside: - 1 Touchbar with vertical locking rod Outside: - 1 Lever handle with round rosette Product components for double doors 10 Inside: - Action leaf: 1 Touchbar - Inactive leaf: 1 Touchbar with vertical locking rod and 1 striking plate Outside: - 1 Lever handle with round rosette Touchbar Inside: - Action and inactive leaf: Touchbar with vertical locking rod Outside: - 1 Lever handle with round rosette Supplied with 1 Touchbar 1 Striking plate Cat. No. Touchbar 911.56.036 Packing: 1 pc. We reserve the right to alter specifications without notice (HMA Basic 2011/12). HMA 10.50 New products and systems: www.hafele.com
- Page 1 and 2: Architectural Hardware Door Handles
- Page 3 and 4: Architectural Hardware Door Handles
- Page 5 and 6: Architectural Hardware Door Handles
- Page 7 and 8: Architectural Hardware Door Handles
- Page 9 and 10: Architectural Hardware Door Handles
- Page 11 and 12: Architectural Hardware Door Handles
- Page 13 and 14: Architectural Hardware Door Handles
- Page 15 and 16: Architectural Hardware Door Handles
- Page 17 and 18: Architectural Hardware Door Handles
- Page 19 and 20: Architectural Hardware Door Handles
- Page 21 and 22: Architectural Hardware Locking and
- Page 23 and 24: Architectural Hardware Locking and
- Page 25 and 26: Architectural Hardware Locking and
- Page 27 and 28: Architectural Hardware Locking and
- Page 29 and 30: Architectural Hardware Locking and
- Page 31 and 32: Architectural Hardware Locking and
- Page 33 and 34: Architectural Hardware Locking and
- Page 35 and 36: Architectural Hardware Locking and
- Page 37 and 38: Architectural Hardware Locking and
- Page 39 and 40: Architectural Hardware Locking and
- Page 41 and 42: Architectural Hardware Locking and
- Page 43: Architectural Hardware Locking and
Architectural Hardware<br />
<strong>Locking</strong> <strong>and</strong> <strong>Security</strong><br />
Panic exit device<br />
Area of application: For rebated or flush, single or double,<br />
wooden or steel doors<br />
Suitable for: Fire resistant <strong>and</strong> smoke control doors<br />
<strong>Door</strong> width: 840 – 914 mm<br />
<strong>Door</strong> thickness: 43.9 – 50.8 mm<br />
Mounting: For DIN left <strong>and</strong> DIN right h<strong>and</strong> use<br />
Function<br />
Opening of door from inside: By pushing the touchbar<br />
Opening of door from outside (optional): By activating the lever h<strong>and</strong>le.<br />
Key locks or unlocks lever h<strong>and</strong>les (ANSI cipher bit function)<br />
Product components for single doors<br />
Inside:<br />
- 1 Touchbar <br />
Outside:<br />
- 1 Lever h<strong>and</strong>le with round rosette <br />
Inside:<br />
- 1 Touchbar with vertical locking rod <br />
Outside:<br />
- 1 Lever h<strong>and</strong>le with round rosette <br />
Product components for double doors<br />
10<br />
Inside:<br />
- Action leaf: 1 Touchbar <br />
- Inactive leaf: 1 Touchbar with vertical locking rod <br />
<strong>and</strong> 1 striking plate <br />
Outside:<br />
- 1 Lever h<strong>and</strong>le with round rosette <br />
Touchbar<br />
Inside:<br />
- Action <strong>and</strong> inactive leaf: Touchbar with vertical locking rod <br />
Outside:<br />
- 1 Lever h<strong>and</strong>le with round rosette <br />
Supplied with<br />
1 Touchbar<br />
1 Striking plate<br />
Cat. No.<br />
Touchbar 911.56.036<br />
Packing: 1 pc.<br />
We reserve the right to alter specifications without notice (HMA Basic 2011/12).<br />
HMA 10.50<br />