F:\测试数据\2010-12\宁波德普\三防灯TOP9118C-HF\3.gms - Tracon
F:\测试数据\2010-12\宁波德普\三防灯TOP9118C-HF\3.gms - Tracon
F:\测试数据\2010-12\宁波德普\三防灯TOP9118C-HF\3.gms - Tracon
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Zhejiang University Sensing instruments Co,.Ltd<br />
http://www.sensing.net.cn<br />
Email:Email:service@sensing.net.com<br />
Tel:086-0571-85021543 Fax:086-0571-87977635<br />
Address:No.525 Xixi Road,Hangzhou,China<br />
宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />
LumCAT: 三 防 灯<br />
Luminaire: TOP9136C-HF<br />
Report No: SENSING20110112S002 Voltage(V): 220.000<br />
Test No: Current(A): 0.156<br />
LampCAT: : TOP T8 36W Power (W): 34.100<br />
Lamp flux(lm): 2011.0 PF: 0.990<br />
Number of Lamps: 1<br />
Ballast type:<br />
Length(mm): 1250<br />
Width(mm): 90<br />
Phm Type: C<br />
Height(mm): 45<br />
Photometric Results<br />
Lumens(lm): 1648.14<br />
Efficiency(%): 81.96%<br />
Lumens(lm)/Power(W): 48.33<br />
Central intensity(cd): 323.645<br />
Maximum intensity(cd): 332.480<br />
Angle of maximum intensity: C=0.0 γ=30.0<br />
Beam Angle(50%lmax): [C0_180]Left=62.3 Right=62.8<br />
[C90_270]Left=N.A. Right=N.A.<br />
Field angle(10%lmax): [C0_180]Left=90.0 Right=90.0<br />
[C90_270]Left=90.0 Right=90.0<br />
Maximum s/h: C0_180=0.76 C90_270=0.62<br />
Up flux rate of lamp(%): 12.62%<br />
Down flux rate of lamp(%): 69.34%<br />
Up flux rate of LUM(%): 15.40%<br />
Down flux rate of LUM(%): 84.60%<br />
CIE Type : Semidirect lighting<br />
Output flux ratio in π solid angle : 52.023%<br />
Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />
Temperature(°C): 19.0 Humidity(%): 48.0% Distance(m): 12.45