01.01.2014 Views

M-Bus Communication Protocol - Gossen-Metrawatt

M-Bus Communication Protocol - Gossen-Metrawatt

M-Bus Communication Protocol - Gossen-Metrawatt

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Bit<br />

Nr.<br />

41<br />

42<br />

43<br />

44<br />

45<br />

46<br />

47<br />

48<br />

49<br />

50<br />

51<br />

52<br />

53<br />

54<br />

55<br />

56<br />

57<br />

58<br />

59<br />

60<br />

61<br />

62<br />

Bit Value Measure Unit Bit<br />

Phase 1, 2, 3 Exported Inductive Energy Total (Reactive or<br />

Apparent)<br />

3-Phase Exported Inductive Energy Total (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Imported Inductive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

3-Phase Imported Inductive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Exported Inductive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

3-Phase Exported Inductive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Imported Inductive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

3-Phase Imported Inductive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Exported Inductive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

3-Phase Exported Inductive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Imported Capacitive Energy Total (Reactive or<br />

Apparent)<br />

3-Phase Imported Capacitive Energy Total (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Exported Capacitive Energy Total (Reactive or<br />

Apparent)<br />

3-Phase Exported Capacitive Energy Total (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Imported Capacitive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

3-Phase Imported Capacitive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Exported Capacitive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

3-Phase Exported Capacitive Energy Tariff 1 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Imported Capacitive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

3-Phase Imported Capacitive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

Phase 1, 2, 3 Exported Capacitive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

3-Phase Exported Capacitive Energy Tariff 2 (Reactive or<br />

Apparent)<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

0.1varh/0.1VAh<br />

xxxx xxx1b<br />

xxxx xx1xb<br />

xxxx x1xxb<br />

xxxx 1xxxb<br />

xxx1 xxxxb<br />

xx1x xxxxb<br />

x1xx xxxxb<br />

1xxx xxxxb<br />

xxxx xxx1b<br />

xxxx xx1xb<br />

xxxx x1xxb<br />

xxxx 1xxxb<br />

xxx1 xxxxb<br />

xx1x xxxxb<br />

x1xx xxxxb<br />

1xxx xxxxb<br />

xxxx xxx1b<br />

xxxx xx1xb<br />

xxxx x1xxb<br />

xxxx 1xxxb<br />

xxx1 xxxxb<br />

xx1x xxxxb<br />

63 All Energy Balance (Reactive or Apparent) 0.1varh/0.1VAh x1xx xxxxb<br />

64 All Energy Partial (Reactive or Apparent) 0.1varh/0.1VAh 1xxx xxxxb<br />

Table B1 –Bit Division of Every Parameter Set Byte<br />

Parameter<br />

Set<br />

PS5<br />

PS6<br />

PS7<br />

English<br />

M-<strong>Bus</strong> communication protocol 51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!