5. Hogs will be moni<strong>to</strong>red for insensibility and additional adjustments will be made <strong>to</strong> the stun time<br />

<strong>to</strong> eliminate returning <strong>to</strong> sensibility.<br />

6. Upper management will conduct a meeting with Stunning personnel on the necessity <strong>to</strong> take<br />

immediate action (line s<strong>to</strong>ppage) when a hog sensibility issue arises. Company will take<br />

immediate action <strong>to</strong> control situation.<br />

On Apri126, <strong>2013</strong> you submitted your preventive measures:<br />

Immediate Review:<br />

I) Reviewed Stun Tracking program for opera<strong>to</strong>r errors or significant changes in amperage or<br />

voltage. Program evaluates every stun. Stunning log didn't show any outstanding deviations in<br />

the stunning operation in either opera<strong>to</strong>r errors or current fluctuations. Reviewed findings with<br />

Management personnel.<br />

2) Reviewed wetting <strong>of</strong> hogs prior <strong>to</strong> entering restrainer and wand placement on hogs. Concern was<br />

that the hogs were being over sprayed which could cause random electrical shortage. Slaughter<br />

Management personnel found the hogs were being properly wetted and this concern was<br />

dismissed. Wand placement was also checked. Wand placement was good. Slaughter<br />

Superintendent reviewed the concerns with responsible personnel.<br />

3) Maintenance disassembled, cleaned, reassembled, and tested all 5 sets <strong>of</strong> stunner wands.<br />

Replaced male plug and head side stunner tip on# I wand. Task was completed on 4/17/13 by<br />

Maintenance personnel.<br />

4) Disassembled both female plugs for stunner wand connections and inspected for moisture,<br />

corrosion, and loose connections. Task was completed on 4/17/13 by Maintenance personnel.<br />

Immediate Corrective Actions:<br />

1) Replaced 16 restrainer slats (Eliminated possible current grounding issue). Task was<br />

completed on 4118/13 by Maintenance personnel.<br />

2) Increased stun dwell time. Dwell time was increased prior <strong>to</strong> start <strong>of</strong> stunning operations by<br />

Maintenance personnel on 4/18/13.Stun time was verified through Stun Tracking Program.<br />

Current average dwell time is at 4.5 seconds.<br />

3) Replaced one <strong>of</strong>the stunning control boxes with backup box. Replaced electrical contacts in<br />

box. Back up box was installed on 4/18/13 by Maintenance personnel. Electrical contacts<br />

were replaced by Maintenance personnel on 4/18/13.<br />

4) Installed new wiring <strong>from</strong> stunning control box <strong>to</strong> wand's plugs. Replaced cords and female<br />

plugs which connect <strong>to</strong> stunning wands. Tasks were completed on 4/18/13 by Maintenance<br />

personnel.


5) Modified roller bed on exit end <strong>of</strong> restrainer. New plastic roller was installed on 4/18/13 by<br />

Maintenance personnel.<br />

6) Ordered and installed a new stunning box <strong>to</strong> replace existing box. Box was ordered on<br />

4/18/13 and installed on 4/20/13. New box was installed by Maintenance personnel.<br />

The investigation in<strong>to</strong> the occurrence did not provide any one specific failure. As a result, replacement<br />

stunning boxes, new wiring <strong>from</strong> stunning boxes <strong>to</strong> stunning cords, new plugs on the stunning wands,<br />

new stunning cords, and replacement restrainer slats were installed. Moving forward PIP will implement<br />

the following ongoing corrective actions <strong>to</strong> prevent reoccurrence:<br />

l) All Stunning and QA personnel will be re-trained on proper stunning techniques and<br />

determining sensibility <strong>of</strong> hogs. This training will include Electric Stunning <strong>of</strong>Pigs and<br />

Sheep (updated Apri12011) and How <strong>to</strong> Determine Insensibility in Cattle, Pigs, and<br />

Sheep in Slaughter Plants (Revised Nov. 2010) by Temple Grandin, Dept. <strong>of</strong> Animal<br />

Science, CSU. Documented retraining was completed on 4/26/13. Training records are<br />

available <strong>to</strong> <strong>FSIS</strong> for review. Copies <strong>of</strong> training records will accompany this response.<br />

2) Stunning wands will be completely gone through on a weekly basis <strong>to</strong> clean or replace any<br />

parts that have become damaged or less effective through use. Actions will be documented on<br />

weekly PM log. Records are available <strong>to</strong> <strong>FSIS</strong> personnel upon request. This will be an<br />

ongomg program.<br />

3) Pre-operational testing <strong>of</strong> stunning system by Maintenance personnel <strong>to</strong> ensure proper<br />

operation. Maintenance management moni<strong>to</strong>red setup testing and startup <strong>of</strong> Stunners. This<br />

testing included both stunning boxes. Maintenance management will moni<strong>to</strong>r setup for 2<br />

weeks effective 4/18/13. Setup will be reevaluated at that time. Verification <strong>of</strong> stunning boxes<br />

pre-operational testing is recorded on Stun Tracking Program located in the QA <strong>of</strong>fice. QA<br />

supervisor will review tests for accuracy (99% or higher) and inform Maintenance if<br />

additional testing needs <strong>to</strong> be performed. These records are s<strong>to</strong>red electronically and available<br />

<strong>to</strong> <strong>FSIS</strong> personnel upon request. Management will initial and record any observations or<br />

deviations on a print out <strong>of</strong> the test stuns.<br />

4) Hourly sensibility audits conducted by QA personnel. Frequency <strong>to</strong> QA sensibility audits<br />

have been increased <strong>from</strong> 20 hogs <strong>to</strong> 30 effective 4/26/13 for 30 days and re-evaluated. These<br />

records are s<strong>to</strong>red in the Production Daily Packets and available <strong>to</strong> <strong>FSIS</strong> upon request.<br />

5) Trained personnel in place <strong>to</strong> apply measures <strong>to</strong> render animals insensible ifsensibility is<br />

observed. Trained employee is responsible for moni<strong>to</strong>ring the sensibility <strong>of</strong> each hog on the<br />

bleed rail. Any hog displaying signs <strong>of</strong> sensibility will be knocked. Number <strong>of</strong> knocks<br />

conducted in an hourly period will be communicated <strong>to</strong> QA personnel conducting hourly<br />

sensibility checks. The number <strong>of</strong> knocks and reason for it will be documented on the<br />

Sensibility Audit form.


(b) (7)(C)<br />

(b) (7)(C)<br />

(b) (7)(C)<br />

(b) (7)(C)