5. The grade and the guaranteed analysis of a fertilizer express the minimum total nitrogen content, and the<br />
minimum available phosphoric acid content (P O) and the minimum water soluble potash (K O) content in<br />
that order 15-15-0 grade fertilizer contains 15 percent total nitrogen, 15 percent available phosphoric acid, and<br />
zero percent water soluble potash.<br />
16.10 - Construction Methods<br />
The fertilizer shall be applied with approved mechanical spreaders or with the hydraulic seeder, at the rate<br />
specified in the specifications and shall uniformly cover the entire area. Fertilizer shall be applied to the<br />
seed bed or area to be sodded prior to seeding or sodding.<br />
16.11 - Basis of Payment<br />
This work will not be paid for directly but shall be considered as subsidiary work pertaining to the items<br />
which require the use of fertilizer.<br />
III. EROSION CONTROL BLANKET<br />
16.12 - Description<br />
This work shall consist of placing erosion control blanket on areas designated by the engineer or shown on<br />
the plans.<br />
16.13 - Material Requirements<br />
The erosion control blanket shall be 100% agricultural straw stitched with two photo/degradeable<br />
polypropylene nets (0.558 x 0.5 inch mesh size) The blanket shall be netted on both sides and sewn together<br />
with biodegradeable multifilament thread.<br />
Property Test Method Result<br />
Thickness ASTM D5199/ECTC 0.34 in.<br />
Resiliency ECTC Guidelines 56%<br />
Mass/unit area ASTM D5261 9.2 oz/sy<br />
Water Absorption ASTM D1117/ECTC 513%<br />
Swell ECTC Guidelines 10%<br />
Stiffness/Flexibility<br />
ASTM D1388/ECTC<br />
Light Penetration ECTC Guidelines 5%<br />
Smolder Resistance ECTC Guidelines 0.4 x 2.4 in.<br />
MD Tensile Strength ASTM D5035/ECTC 14.9 x 8.0 lbs/in.<br />
MD Elongation ASTM D5035/ECTC 35.4 x 25.6%<br />
TD Tensile Strength ASTM D5035/ECTC 96 lbs/ft<br />
TD Elongation ASTM D5035/ECTC 27.3%<br />
16.14 - Construction Methods<br />
1. SLOPE APPLICATION:<br />
A. Staple the blanket at the top of the slope in a 6” deep x 6” wide trench. Backfill and compact the<br />
trench so that the water will flow evenly onto the blanket.<br />
16 - 5