<strong>GC</strong> CHROMATOGRAMS | PETROLEUM & PETROCHEMICAL<br />
Hydrocarbon Gases<br />
Propylene and C1-C5 Hydrocarbons<br />
on Rt®-Alumina BOND/Na2SO4<br />
(PLOT)<br />
Peaks<br />
1. Methane<br />
2. Ethane<br />
3. Ethylene<br />
4. Propane<br />
5. Cyclopropane<br />
6. Propylene<br />
7. Isobutane<br />
8. n-Butane<br />
9. Propadiene<br />
10. Acetylene<br />
11. trans-2-Butene<br />
12. 1-Butene<br />
13. Isobutylene<br />
14. cis-2-Butene<br />
15. Isopentane<br />
16. n-Pentane<br />
17. 1,3-Butadiene<br />
18. Methylacetylene<br />
Column Rt®-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 μm (cat.# 19756)<br />
Sample<br />
Propylene and C1-C5 hydrocarbons<br />
Injection<br />
Inj. Vol.:<br />
10 μL split<br />
Liner: 2 mm splitless (cat.# 20712)<br />
Inj. Temp.: 200 °C<br />
Split Vent<br />
Flow Rate: 35 mL/min<br />
Oven<br />
Oven Temp: 50 °C to 150 °C at 6 °C/min<br />
Carrier Gas He, constant pressure (10 psi, 68.9 kPa)<br />
Linear Velocity: 47 cm/sec @ 50 °C<br />
Detector FID @ 200 °C<br />
Make-up Gas<br />
Type:<br />
N2<br />
Data Rate: 20 Hz<br />
Instrument HP5890 <strong>GC</strong><br />
<strong>GC</strong>_PC01142<br />
C1-C5 Hydrocarbons on Rt®-Alumina BOND/MAPD<br />
(PLOT)<br />
NEW!<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12 13<br />
14<br />
15<br />
16<br />
17<br />
Peaks<br />
1. Methane<br />
2. Ethane<br />
3. Ethylene<br />
4. Propane<br />
5. Cyclopropane<br />
6. Propylene<br />
7. Acetylene<br />
8. Propadiene<br />
9. n-Butane<br />
10. trans-2-Butene<br />
11. 1-Butene<br />
12. Isobutene<br />
13. cis-2-Butene<br />
14. Isopentane<br />
15. n-Pentane<br />
16. 1,3-Butadiene<br />
17. Methyl acetylene<br />
Column<br />
Rt®-Alumina BOND/MAPD, 50 m, 0.53 mm ID, 10 μm<br />
(cat.# 19778)<br />
Sample DCG custom standard (cat.# 547267)<br />
Injection<br />
Inj. Vol.:<br />
5 μL split<br />
Liner: 2 mm single taper (cat.# 20795)<br />
Inj. Temp.: 200 °C<br />
Split Vent<br />
Flow Rate: 80 mL/min<br />
Oven<br />
Oven Temp: 130 °C (hold 8 min)<br />
Carrier Gas He, constant pressure (4.4 psi, 30.3 kPa)<br />
Temp.: 130 °C<br />
Detector FID @ 200 °C<br />
Instrument HP5890 <strong>GC</strong><br />
0 2<br />
4 6 8 10 12 14<br />
Time (min)<br />
<strong>GC</strong>_PC1213<br />
1-800-356-1688 or 1-814-353-1300 www.restek.com 661