<strong>GC</strong> CHROMATOGRAMS | PETROLEUM & PETROCHEMICAL<br />

Hydrocarbon Gases<br />

Butane Lighter Fluid on Rt®-Alumina BOND/Na2SO4<br />

(PLOT)<br />

Peaks<br />

1. Methane<br />

2. Ethane<br />

3. Propane<br />

4. Isobutane<br />

5. n-Butane<br />

6. trans-2-Butene<br />

7. 1-Butene<br />

8. Isobutylene<br />

Column Rt®-Alumina BOND/Na2SO4, 50 m,<br />

0.53 mm ID, 10 μm (cat.# 19756)<br />

Sample<br />

Butane lighter fluid<br />

Injection<br />

Inj. Vol.:<br />

100 μL split<br />

Liner:<br />

Splitless taper (2 mm)<br />

(cat.# 20795)<br />

Inj. Temp.: 200 °C<br />

Split Vent<br />

Flow Rate: 400 mL/min<br />

Oven<br />

Oven Temp: 45 °C (hold 1 min) to 200 °C<br />

at 10 °C/min (hold 3.5 min)<br />

Carrier Gas H2, constant pressure<br />

(8.0 psi, 55.2 kPa)<br />

Linear Velocity: 74 cm/sec @ 45 °C<br />

Detector FID @ 200 °C<br />

Make-up Gas<br />

Type:<br />

N2<br />

Data Rate: 20 Hz<br />

Instrument<br />

Notes<br />

HP5890 <strong>GC</strong><br />

100 μL sample loop on gas sampling<br />

valve, split<br />

Propane Camping Fuel on Rt®-Alumina BOND/Na2SO4<br />

(PLOT)<br />

Peaks<br />

1. Methane<br />

2. Ethane<br />

3. Ethylene<br />

4. Propane<br />

5. Propylene<br />

6. Isobutane<br />

7. n-Butane<br />

Column<br />

Rt®-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID,<br />

10 μm (cat.# 19756)<br />

Sample<br />

Propane camping fuel<br />

Injection<br />

Inj. Vol.:<br />

100 μL split<br />

Liner: Splitless taper (2 mm) (cat.# 20795)<br />

Inj. Temp.: 200 °C<br />

Split Vent<br />

Flow Rate: 400 mL/min<br />

Oven<br />

Oven Temp: 45 °C (hold 1 min) to 200 °C at 10 °C/min<br />

(hold 3.5 min)<br />

Carrier Gas H2, constant pressure (8.0 psi, 55.2 kPa)<br />

Linear Velocity: 74 cm/sec @ 45 °C<br />

Detector FID @ 200 °C<br />

Make-up Gas<br />

Type:<br />

N2<br />

Data Rate: 20 Hz<br />

Instrument HP5890 <strong>GC</strong><br />

Notes<br />

100 μL sample loop on gas sampling valve, split<br />

<strong>GC</strong>_PC01083<br />

<strong>GC</strong>_PC01084<br />

Natural Gas on ShinCarbon ST<br />

(micropacked)<br />

Natural Gas #2 on Rt®-QS-BOND<br />

(PLOT)<br />

1<br />

2<br />

3<br />

Peaks<br />

1. C1<br />

2. C2<br />

3. C3<br />

4. iC4-isobutane<br />

5. C4<br />

6. iC5-isopentane<br />

7. nC5<br />

8. Hexanes<br />

Column<br />

SilcoSmooth® tubing, 100/120 mesh on<br />

Shincarbon ST, 1 m, 1/16 OD, 1.0 mm ID<br />

(cat.# 19809)<br />

Sample<br />

C1-C6 hydrocarbons<br />

Conc.:<br />

0.5-8% varied<br />

Injection<br />

Packed on-column<br />

Inj. Temp.: 200 °C<br />

Oven<br />

Oven Temp: 125 °C to 250 °C at 16 °C/min<br />

Carrier Gas He, constant flow<br />

Flow Rate: 10 mL/min<br />

Detector FID @ 250 °C<br />

Peaks<br />

1. Methane<br />

2. Ethane<br />

3. Propane<br />

4. Isobutane<br />

5. n-Butane<br />

6. Isopentane<br />

7. n-Pentane<br />

8. Hexanes & hexenes<br />

4 5<br />

<strong>GC</strong>_PC01013<br />

0 10<br />

67<br />

Time (min)<br />

20 30<br />

<strong>GC</strong>_PC00672<br />

8<br />

Column Rt®-QS-BOND, 30 m, 0.53 mm ID, 20 μm (cat.# 19738)<br />

Sample<br />

Natural gas mix (mole%)<br />

Injection<br />

Inj. Vol.: 20 μL split (split ratio 10:1)<br />

Liner: Siltek® splitless taper (4 mm) (cat.# 20798-214.1)<br />

Inj. Temp.: 240 °C<br />

Oven<br />

Oven Temp: 40 °C (hold 2 min) to 225 °C at 20 °C/min (hold 5 min)<br />

Carrier Gas He, constant flow<br />

Flow Rate: 5.7 mL/min<br />

Detector FID @ 240 °C<br />

1-800-356-1688 or 1-814-353-1300 www.restek.com 659

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!