GC Chromatograms
GC Chromatograms
GC Chromatograms
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>GC</strong> CHROMATOGRAMS | FORENSICS<br />
GHB/GBL<br />
GHB Analysis (GBL and AMGBL) on Rtx®-BAC Plus 1<br />
1<br />
Peaks<br />
1. GBL<br />
2. AMGBL<br />
NEW!<br />
4.6 4.8 5 5.2 5.4 5.6 5.8 6 6.2 6.4<br />
Time (min)<br />
<strong>GC</strong>_CF1164<br />
2<br />
Column Rtx®-BAC Plus 1, 30 m, 0.32 mm ID, 1.8 μm (cat.# 18004)<br />
Sample Gamma-butyrolactone (GBL) (cat.# 34077)<br />
Alpha-methylene-gamma-butyrolactone (AMGBL) (cat.# 34079)<br />
Injection Headspace-loop split (split ratio 10:1)<br />
Liner: 1 mm straight inlet liner (cat.# 20972)<br />
Headspace-Loop<br />
Inj. Port Temp.: 200 °C<br />
Instrument: Tekmar HT3<br />
Inj. Time:<br />
1 min<br />
Transfer Line<br />
Temp.: 125 °C<br />
Valve Oven Temp.: 125 °C<br />
Sample Temp.: 100 °C<br />
Sample Equil.<br />
Time:<br />
10 min<br />
Vial Pressure: 30 psi<br />
Pressurize Time: 2 min<br />
Loop Pressure: 20 psi<br />
Loop Fill Time: 1 min<br />
Oven<br />
Oven Temp: 80 °C (hold 0 min) to 180 °C at 10 °C/min (hold 0 min)<br />
Carrier Gas He, constant flow<br />
Linear Velocity: 48 cm/sec<br />
Detector FID @ 240 °C<br />
Make-up Gas<br />
Flow Rate: 30 mL/min<br />
Make-up Gas<br />
Type:<br />
N2<br />
Instrument<br />
Notes<br />
Agilent/HP6890 <strong>GC</strong><br />
Sample was prepared by injecting 1 μL of each standard into a<br />
capped headspace vial. The mass of each compound inside the<br />
headspace vial was 1 μg.<br />
Headspace concentrator courtesy of Teledyne Tekmar, Mason, OH.<br />
Now Online!<br />
Our EZ<strong>GC</strong> Web App Will Kick-Start<br />
Your <strong>GC</strong> Method Development<br />
• EZ to Register – If you have a Restek login,<br />
you’re already done! (And if you don’t, you can<br />
get one at no charge and with no hassle.)<br />
• EZ to Get Started – A quick, 5-minute video<br />
will show you everything you need to know.<br />
• EZ to Use – Just enter your target<br />
compounds, and in seconds, the EZ<strong>GC</strong><br />
system gives you a customized method,<br />
including column, conditions, and model<br />
chromatogram.<br />
• EZ to Analyze – Model chromatograms are fully<br />
interactive. Zoom in, view chemical structures,<br />
and even overlay mass spectra.<br />
• EZ to Save – Print your chromatogram and<br />
custom settings, or save them for future reference.<br />
Start developing incredible <strong>GC</strong> methods today!<br />
www.restek.com/ezgc<br />
1-800-356-1688 or 1-814-353-1300 www.restek.com 651