30.12.2013 Views

GC Chromatograms

GC Chromatograms

GC Chromatograms

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>GC</strong> CHROMATOGRAMS | FOODS, FLAVORS, & FRAGRANCES<br />

Cholesterols<br />

Underivatized Cholesterol on Rxi®-5ms<br />

A. Temperature program conditions.<br />

Oven temp.: 200 °C (hold 1 min) to 330 °C @ 20 °C/min (hold 7.5 min)<br />

Rxi® Technology!<br />

Exceptionally inert, ultra low-bleed<br />

capillary columns.<br />

Peaks<br />

1. 5--Cholestane (IS)<br />

2. Cholesterol<br />

B. Isothermal conditions will maximize sample throughput.<br />

Oven temp.: 300 °C (hold 10 min)<br />

One column, many<br />

cholesterol methods.<br />

<strong>GC</strong>_FF00881<br />

Column<br />

Rxi® -5ms, 15 m, 0.25 mm ID, 0.25 μm<br />

(cat.# 13420)<br />

Sample<br />

1,000 μg/mL cholesterol in DMF<br />

1,000 μg/mL 5--cholestane in hexane<br />

25 ng cholesterol, 150 ng 5--cholestane<br />

on column<br />

Injection<br />

Inj. Vol.: 1 μL split (split ratio 20:1)<br />

Liner: Splitless taper (4 mm) w/wool (cat.# 22405)<br />

Inj. Temp.: 250 °C<br />

Carrier Gas He, constant pressure (9.7 psi, 66.9 kPa)<br />

Linear Velocity: 24 cm/sec @ 200 °C<br />

Detector FID @ 340 °C<br />

<strong>GC</strong>_FF00882<br />

Derivatized Cholesterol on Rxi®-5ms<br />

A. Temperature program conditions.<br />

Oven temp.: 200 °C (hold 1 min) to 330 °C @ 20 °C/min (hold 7.5 min)<br />

Rxi® Technology!<br />

Exceptionally inert, ultra low-bleed<br />

capillary columns.<br />

Peaks<br />

1. 5--Cholestane (IS)<br />

2. Cholesterol<br />

B. Isothermal conditions will maximize sample throughput.<br />

Oven temp.: 300 °C (hold 10 min)<br />

<strong>GC</strong>_FF00883 Column Rxi®-5ms, 15 m, 0.25 mm ID, 0.25 μm<br />

(cat.# 13420)<br />

Sample<br />

1,000 μg/mL cholesterol in hexane<br />

1,000 μg/mL 5--cholestane in hexane<br />

50 ng derivatized cholesterol, 150 ng<br />

5--cholestane on column<br />

Injection<br />

Inj. Vol.: 1 μL split (split ratio 20:1)<br />

Liner: Splitless taper (4 mm) w/wool (cat.# 22405)<br />

Inj. Temp.: 250 °C<br />

Carrier Gas He, constant pressure (9.7 psi, 66.9 kPa)<br />

Linear Velocity: 24 cm/sec @ 200 °C<br />

Detector FID @ 340 °C<br />

<strong>GC</strong>_FF00884<br />

632 www.restek.com 1-800-356-1688 or 1-814-353-1300