30.12.2013 Views

GC Chromatograms

GC Chromatograms

GC Chromatograms

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>GC</strong> CHROMATOGRAMS | FOOD SAFETY<br />

Packaging Volatiles<br />

Food Packaging Volatiles by Purge & Trap <strong>GC</strong>-MS on Rtx®-5MS<br />

(Purge & Trap <strong>GC</strong>-MS)<br />

Peaks<br />

1. Ethyl acetate<br />

2. Toluene<br />

3. 4-Heptanone<br />

4. n-Butyl ether<br />

5. Styrene<br />

6. Alkanes<br />

Column Rtx®-5MS, 30 m, 0.25 mm ID, 1.00 μm (cat.# 12653)<br />

Sample<br />

Overwrap, inner bowl<br />

Injection Purge and trap split (split ratio 20:1)<br />

Liner:<br />

1 mm ID<br />

Inj. Temp.: 250 °C<br />

Purge and Trap<br />

Instrument: Tekmar LSC-3100 purge & trap<br />

Trap Type: Vocarb 3000, type K<br />

Purge:<br />

10 min @ 60 °C, flow 40 mL/min<br />

Dry Purge: 3 min, flow 40 mL/min<br />

Desorb Preheat<br />

Temp.: 220 °C<br />

Desorb:<br />

2 min @ 245 °C, flow 40 mL/min<br />

Bake: 6 min @ 230 °C<br />

Interface<br />

Connection: Injection port<br />

Transfer Line<br />

Tubing: Siltek®/Sulfinert® tubing (cat.# 22501)<br />

Oven<br />

Oven Temp: 50 °C to 92 °C at 3 °C/min to 220 °C at 20 °C/min (hold 1 min)<br />

Carrier Gas He, constant flow<br />

Flow Rate: 1 mL/min<br />

Linear Velocity: 36 cm/sec<br />

Detector<br />

MS<br />

Mode:<br />

Scan<br />

Source Temp.: 280 °C<br />

Electron Energy: EI @ 70 eV<br />

Scan Range: 35-260 amu<br />

Instrument HP6890 <strong>GC</strong> & 5973 MSD<br />

<strong>GC</strong>_FF00462<br />

Food Packaging Volatiles by Purge & Trap <strong>GC</strong>-MS on Rtx®-5MS<br />

(Purge & Trap <strong>GC</strong>-MS)<br />

Peaks<br />

1. Tetrahydrofuran<br />

2. Ethylbenzene<br />

3. 4-Heptanone<br />

4. Styrene<br />

5. Benzaldehyde<br />

6. Nonanal<br />

7. Decanal<br />

8. Cinnamaldehyde<br />

Column Rtx®-5MS, 30 m, 0.25 mm ID, 1.00 μm (cat.# 12653)<br />

Sample<br />

Overwrap, lid of bowl<br />

Injection Purge and trap split (split ratio 20:1)<br />

Liner:<br />

1 mm ID<br />

Inj. Temp.: 250 °C<br />

Purge and Trap<br />

Instrument: Tekmar LSC-3100 purge & trap<br />

Trap Type: Vocarb 3000, type K<br />

Purge:<br />

10 min @ 60 °C, flow 40 mL/min<br />

Dry Purge: 3 min, flow 40 mL/min<br />

Desorb Preheat<br />

Temp.: 220 °C<br />

Desorb:<br />

2 min @ 245 °C, flow 40 mL/min<br />

Bake: 6 min @ 230 °C<br />

Interface<br />

Connection: Injection port<br />

Transfer Line<br />

Tubing: Siltek®/Sulfinert® tubing (cat.# 22501)<br />

Oven<br />

Oven Temp: 50 °C to 92 °C at 3 °C/min to 220 °C at 20 °C/min (hold 1 min)<br />

Carrier Gas He, constant flow<br />

Flow Rate: 1 mL/min<br />

Linear Velocity: 36 cm/sec<br />

Detector<br />

MS<br />

Mode:<br />

Scan<br />

Source Temp.: 280 °C<br />

Electron Energy: EI @ 70 eV<br />

Scan Range: 35-260 amu<br />

Instrument HP6890 <strong>GC</strong> & 5973 MSD<br />

<strong>GC</strong>_FF00461<br />

630 www.restek.com 1-800-356-1688 or 1-814-353-1300