GC Chromatograms
GC Chromatograms
GC Chromatograms
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>GC</strong> CHROMATOGRAMS | ENVIRONMENTAL<br />
Explosives<br />
Explosives on Rtx®-200<br />
Peaks<br />
1. 2-Nitrotoluene<br />
2. 3-Nitrotoluene<br />
3. 4-Nitrotoluene<br />
4. 2,3-Diaminotoluene<br />
5. 2,6-Diaminotoluene<br />
6. 2,4-Diaminotoluene<br />
7. 1,4-Dinitrobenzene<br />
8. 2,6-Dinitrotoluene<br />
9. 2-Amino-6-nitrotoluene<br />
10. 1,3-Dinitrobenzene<br />
11. 2,4-Dinitrotoluene<br />
12. 2-Amino-4-nitrotoluene<br />
13. 2,3-Dinitrotoluene<br />
14. 3,4-Dinitrotoluene<br />
15. 3-Nitrobiphenyl<br />
16. 2,4,6-Trinitrotoluene<br />
17. 2,4,5-Trinitrotoluene<br />
18. 4-Amino-2,6-dinitrotoluene<br />
19. 2,3,4-Trinitrotoluene<br />
20. 1,3-Dinitronaphthalene<br />
21. 2,6-Diamino-4-nitrotoluene<br />
22. 2-Amino-4,6-dinitrotoluene<br />
23. 2,2'-Dinitrobiphenyl<br />
Column Rtx®-200, 30 m, 0.25 mm ID, 0.25 μm (cat.# 15023)<br />
Sample<br />
Explosives sample<br />
Conc.:<br />
20 ng/μL<br />
Injection<br />
Inj. Vol.:<br />
1 μL splitless (hold 0.6 min)<br />
Inj. Temp.: 280 °C<br />
Oven<br />
Oven Temp:<br />
80 °C (hold 2 min) to 260 °C at 3 °C/min (hold 2 min)<br />
Carrier Gas<br />
He, constant pressure<br />
Linear Velocity: 20 cm/sec @ 80 °C<br />
Detector<br />
MS<br />
Mode:<br />
Scan<br />
Transfer Line Temp.: 300 °C<br />
Analyzer Type: Quadrupole<br />
Ionization Mode: EI<br />
<strong>GC</strong>_EV00060<br />
Now Online!<br />
Our EZ<strong>GC</strong> Web App Will Kick-Start<br />
Your <strong>GC</strong> Method Development<br />
• EZ to Register – If you have a Restek login,<br />
you’re already done! (And if you don’t, you can<br />
get one at no charge and with no hassle.)<br />
• EZ to Get Started – A quick, 5-minute video<br />
will show you everything you need to know.<br />
• EZ to Use – Just enter your target<br />
compounds, and in seconds, the EZ<strong>GC</strong><br />
system gives you a customized method,<br />
including column, conditions, and model<br />
chromatogram.<br />
• EZ to Analyze – Model chromatograms are fully<br />
interactive. Zoom in, view chemical structures,<br />
and even overlay mass spectra.<br />
• EZ to Save – Print your chromatogram and<br />
custom settings, or save them for future reference.<br />
Start developing incredible <strong>GC</strong> methods today!<br />
www.restek.com/ezgc<br />
590 www.restek.com