30.12.2013 Views

GC Chromatograms

GC Chromatograms

GC Chromatograms

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>GC</strong> CHROMATOGRAMS | PETROLEUM & PETROCHEMICAL<br />

Permanent Gases, Sulfur Compounds<br />

Permanent Gases on MXT®-Msieve 5A<br />

NEW!<br />

Peaks<br />

1. Helium<br />

2. Argon<br />

3. Oxygen<br />

4. Nitrogen<br />

5. Methane<br />

6. Carbon monoxide<br />

<strong>GC</strong>_PC1182<br />

Column MXT®-Msieve 5A, 30 m, 0.53 mm ID, 50 μm (cat.# 79723)<br />

Sample<br />

Conc.:<br />

1% in hydrogen<br />

Injection split (split ratio 50:1)<br />

Oven<br />

Oven Temp.: 30 °C<br />

Carrier Gas H2<br />

Detector<br />

μ-TCD<br />

Sulfur in Gasoline on Rtx®-1<br />

Peaks<br />

1. Thiophene<br />

2. 2-Methylthiophene<br />

3. 3-Methylthiophene<br />

4. 2-Ethylthiophene<br />

5. Alkylthiophenes<br />

6. Benzothiophene<br />

7. Methylbenzothiophenes<br />

8. Dimethylbenzothiophenes<br />

Sulfur Compounds on Rxi®-1ms<br />

Rxi® Technology!<br />

Exceptionally inert, ultra low-bleed<br />

capillary columns.<br />

Peaks<br />

1. Hydrogen sulfide<br />

2. Carbonyl sulfide<br />

3. Methyl mercaptan<br />

4. Ethyl mercaptan<br />

5. Dimethyl sulfide<br />

<strong>GC</strong>_AR00861<br />

Column Rtx®-1, 30 m, 0.32 mm ID, 4.0 μm (cat.# 10198)<br />

Sample<br />

Gasoline containing 300 ppm total sulfur<br />

Injection<br />

Inj. Vol.: 1 μL split (split ratio 10:1)<br />

Inj. Temp.: 275 °C<br />

Oven<br />

Oven Temp: 40 °C (hold 3 min) to 275 °C at 10 °C/min (hold 5 min)<br />

Carrier Gas He, constant flow<br />

Flow Rate: 2.5 mL/min<br />

Linear Velocity: 70 cm/sec<br />

Detector SCD @ 275 °C<br />

<strong>GC</strong>_PC00198<br />

Column Rxi®-1ms, 30 m, 0.32 mm ID, 4.00 μm (cat.# 13396)<br />

Sample<br />

Hydrogen sulfide, carbonyl sulfide, methyl mercaptan, ethyl mercaptan,<br />

dimethyl sulfide<br />

Diluent:<br />

helium<br />

Conc.:<br />

100 ppbv<br />

Injection<br />

Splitless<br />

Inj. Temp.: 30 °C<br />

Oven<br />

Oven Temp: 30 °C<br />

Carrier Gas He, constant pressure<br />

Linear Velocity: 48 cm/sec @ 30 °C<br />

Detector SCD @ 800 °C<br />

Notes<br />

Injection: sample loop (30 °C), 1 mL splitless direct<br />

Sample storage & transfer:<br />

SilcoCan® air monitoring canister with Siltek®-treated 1 /4" valve (cat.# 24182-650);<br />

Sulfinert®-treated gas sample loop, 1 cc (cat.# 22848); Sulfinert®-treated gas<br />

sample loop, 10 cc (custom order)<br />

1-800-356-1688 or 1-814-353-1300 www.restek.com 679