<strong>GC</strong> CHROMATOGRAMS | PETROLEUM & PETROCHEMICAL<br />

Hydrocarbons (High-Temperature)<br />

Diesel & Motor Oil on Rtx®-Mineral Oil<br />

C10<br />

Diesel<br />

Conc.<br />

Peaks<br />

(μg/mL)<br />

1. C10 20<br />

2. Diesel 500<br />

3. Motor oil 500<br />

4. C40 20<br />

NEW!<br />

C40<br />

Motor Oil<br />

Column Rtx®-Mineral Oil, 15 m, 0.32 mm ID, 0.10 μm (cat.# 18079)<br />

using IP deactivated guard column 10 m, 0.32 mm ID (cat.# 10047)<br />

with aluminum connector<br />

Sample Diesel #2/motor oil (cat.# 31682)<br />

Extraction solvent stock solution #2 (cat.# 31680)<br />

Diluent:<br />

Hexane/methylene chloride<br />

Injection<br />

Inj. Vol.:<br />

1.0 μL direct<br />

Inj. Temp.: 58 °C<br />

Oven<br />

Oven Temp: 55 °C (hold 1.0 min) to 380 °C at 100 °C/min (hold 6.0 min)<br />

Carrier Gas H2, constant flow<br />

Linear Velocity: 40 cm/sec<br />

Detector FID @ 380 °C<br />

Make-up Gas<br />

Flow Rate: 30 mL/min<br />

Make-up Gas<br />

Type:<br />

N2<br />

Instrument<br />

Notes<br />

Agilent/HP6890 <strong>GC</strong><br />

Direct cool on-column injection, programmed by oven tracking.<br />

Actual guard column length used in application was 2 m.<br />

0 2<br />

4 6 8 10<br />

Time (min.)<br />

<strong>GC</strong>_PC1180<br />

n-alkanes (C10-C40) on Rtx®-Mineral Oil<br />

NEW!<br />

1 2<br />

3<br />

4<br />

5<br />

6<br />

Peaks<br />

1. C10<br />

2. C12<br />

3. C14<br />

4. C16<br />

5. C18<br />

6. C20<br />

7. C22<br />

8. C24<br />

7 8 9 10 11<br />

9. C26<br />

10. C28<br />

11. C30<br />

12. C32<br />

13. C34<br />

14. C36<br />

15. C38<br />

16. C40<br />

12<br />

13 14<br />

15<br />

16<br />

Column Rtx®-Mineral Oil, 15 m, 0.32 mm ID, 0.10 μm (cat.# 18079)<br />

using IP deactivated guard column 10 m, 0.32 mm ID (cat.# 10047)<br />

with aluminum connector<br />

Sample System performance test standard mixture of n-alkanes (cat.# 31678)<br />

Diluent:<br />

Hexane/methylene chloride<br />

Conc.:<br />

20 μg/mL each<br />

Injection<br />

Inj. Vol.:<br />

1.0 μL direct<br />

Inj. Temp.: 58 °C<br />

Oven<br />

Oven Temp: 55 °C (hold 1.0 min) to 380 °C at 100 °C/min (hold 6.0 min)<br />

Carrier Gas H2, constant flow<br />

Linear Velocity: 40 cm/sec<br />

Detector FID @ 380 °C<br />

Make-up Gas<br />

Flow Rate: 30 mL/min<br />

Make-up Gas<br />

Type:<br />

N2<br />

Instrument Agilent/HP6890 <strong>GC</strong><br />

Notes<br />

Direct cool on-column injection, programmed by oven tracking.<br />

Actual guard column length used in application was 2 m.<br />

0 2 4 6 8 10<br />

Time (min.)<br />

<strong>GC</strong>_PC1181<br />

1-800-356-1688 or 1-814-353-1300 www.restek.com 673