30.12.2013 Views

ReliablePerformance. UnbeatablePrice. Plug-and-Play Convenience.

ReliablePerformance. UnbeatablePrice. Plug-and-Play Convenience.

ReliablePerformance. UnbeatablePrice. Plug-and-Play Convenience.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Must-Have Solutions for Your Lab 2013.2<br />

Reliable Performance.<br />

Unbeatable Price.<br />

<strong>Plug</strong>-<strong>and</strong>-<strong>Play</strong> <strong>Convenience</strong>.<br />

Turn to Genuine Restek® Replacement Parts<br />

for your Waters ACQUITY UPLC® systems.<br />

See page 4 for details.<br />

Free posters!<br />

Request yours today<br />

www.restek.com/posters<br />

What’s New?<br />

Restek® Parts for Waters<br />

ACQUITY UPLC® Systems ......................................................4<br />

Reusable EXP® Fittings<br />

for HPLC & UHPLC ....................................................................5<br />

Rxi®-PAH Columns ...................................................................8<br />

Simplifying Column Selection<br />

ASE® 150/350 Replacement Parts ................................... 17<br />

LC-MS/MS Multi-Residue<br />

Pesticide St<strong>and</strong>ards Kit ....................................................... 18<br />

MOSH/MOAH Reference St<strong>and</strong>ards ............................... 18<br />

New & Improved Leak Detector ...................................... 20<br />

GC Troubleshooting Tips<br />

Innovative Chromatography Products www.restek.com • 1-800-356-1688 • 1-814-353-1300


Keep It Clean!<br />

Protect Your Instrument, Column, <strong>and</strong><br />

Budget With Restek® LC Filtration Products<br />

Mobile Phase Management<br />

www.restek.com/MobilePhaseAcc<br />

Bluestem Glass Solvent Filter<br />

• Filters particulates <strong>and</strong> microbial growth out of solvents to extend the life<br />

of columns <strong>and</strong> pump seals.<br />

• 15 μm borosilicate glass frit sits lower than conventional glass filters to<br />

draw more mobile phase from each bottle.<br />

• Blue stem allows instant visual confirmation of upright filter orientation.<br />

Description qty. cat.#<br />

Glass Solvent Filter, 15 μm frit ea. 26431<br />

Hub-Cap Filter Kit<br />

• Transfers <strong>and</strong> filters mobile phase in one step.<br />

• Includes bottle adapter, filter, fittings, tubing, <strong>and</strong> more.<br />

• Fit 4 L or Wheaton bottles; adapter for GL-45 bottles available.<br />

Description qty. cat.#<br />

Hub-Cap Filter Kit for 4 L or Wheaton bottles kit 26395<br />

Replacement Parts qty. cat.#<br />

Polypropylene Membrane Filters, 47 mm, 0.45 μm 100-pk. 26396<br />

Polypropylene Membrane Filters, 47 mm, 0.22 μm 100-pk. 26397<br />

Nylon Membrane Filters, 47 mm, 0.45 μm 100-pk. 26398<br />

Nylon Membrane Filters, 47 mm, 0.22 μm 100-pk. 26399<br />

Hub-Cap Filter Hose Barb ea. 25925<br />

Sample Preparation<br />

www.restek.com/singlestep<br />

Thomson SINGLE StEP® Filter Vials<br />

• Filter samples quickly <strong>and</strong> easily<br />

with a squeeze.<br />

• Color-coded for easy identification.<br />

• Fit most st<strong>and</strong>ard 12x32 mm autosamplers.<br />

Porosity Color qty. cat.#<br />

Nylon<br />

0.2 μm black cap 100-pk. 25891<br />

0.45 μm pink cap 100-pk. 25892<br />

PES (polyethersulfone)<br />

0.2 μm grey cap 100-pk. 25897<br />

0.45 μm orange cap 100-pk. 25898<br />

Patent No. 7,790,117<br />

Porosity Color qty. cat.#<br />

PTFE (polytetrafluoroethylene)<br />

0.2 μm green cap 100-pk. 25893<br />

0.45 μm blue cap 100-pk. 25894<br />

PVDF (polyvinyldifluoride)<br />

0.2 μm red cap 100-pk. 25895<br />

0.45 μm yellow cap 100-pk. 25896<br />

2<br />

visit www.restek.com for all your chromatography needs


LC Accessories<br />

Pump Maintenance<br />

www.restek.com/LCInstParts-Agilent<br />

Frits (PTFE) for Agilent HPLC Systems<br />

• Fits Agilent HPLC 1050, 1100, <strong>and</strong> 1200 systems.<br />

• Similar to Agilent #01018-22707.<br />

Description Model # Similar to Agilent part # qty. cat.#<br />

Frits, PTFE 1050, 1100, 1200 01018-22707 5-pk. 25466<br />

Replacement parts available for all major manufacturers’ instruments.<br />

See www.restek.com/LCacc<br />

Column Protection<br />

www.restek.com/LCguard<br />

UHPLC: UltraShield PreColumn Filter<br />

• Cost-effectively protects UHPLC systems.<br />

• Reliably extends column lifetime.<br />

• Seals leak-tight to 15,000 psi (1,034 bar).<br />

Description qty. cat.#<br />

UltraShield UHPLC PreColumn Filter ea. 24995<br />

UltraShield UHPLC PreColumn Filter 5-pk. 24996<br />

UltraShield UHPLC PreColumn Filter 10-pk. 24997<br />

24995<br />

HPLC: Trident Direct Guard Cartridge System<br />

• Offers three levels of protection: filter alone, guard alone, or<br />

filter <strong>and</strong> guard together.<br />

• Attaches to any HPLC column with CPI- or Waters-style end.*<br />

• Accepts Restek® guard cartridges in a variety of bonded phases.<br />

Description qty. cat.#<br />

High-pressure filter ea. 25082<br />

10 mm guard cartridge holder without filter ea. 25083<br />

10 mm guard cartridge holder with filter ea. 25084<br />

PEEK tip for Waters-style end fittings ea. 25088<br />

PEEK tip for st<strong>and</strong>ard fittings ea. 25087<br />

Replacement Cap Frits : 4 mm 2.0 μm 5-pk. 25022<br />

Replacement Cap Frits : 4 mm 0.5 μm 5-pk. 25023<br />

Replacement Cap Frits : 2 mm 2.0 μm 5-pk. 25057<br />

Replacement Cap Frits : 2 mm 0.5 μm 5-pk. 25990<br />

*The st<strong>and</strong>ard PEEK tip in Trident direct systems is compatible with Parker,<br />

Upchurch Scientific, Valco, <strong>and</strong> other CPI-style fittings. To use Trident direct<br />

25084<br />

systems with Waters-style end fittings, replace the tip with cat.# 25088.<br />

innovative chromatography products<br />

3


NEW!<br />

Genuine Restek ® Replacement Parts<br />

for Waters ACQUITY UPLC ® Systems<br />

Keep your instrument running its best with these rock-solid,<br />

economical alternatives to high-cost vendor parts.<br />

25958<br />

26428<br />

25954<br />

Description Model #<br />

Similar to Waters<br />

part #<br />

qty. cat.#<br />

Needle Assembly, 0.010 mm ID ACQUITY 700002644 ea. 25942<br />

Sample Loop, 10 μL ACQUITY, nanoACQUITY 430001326 ea. 25943<br />

Wash Station O-Ring ACQUITY, nanoACQUITY 700002572 ea. 25944<br />

Metering Syringe, 100 μL ACQUITY, nanoACQUITY 700002570 ea. 25945<br />

Tube Assembly, Inject Outlet ACQUITY 430001084 ea. 25946<br />

Tube Assembly, System Outlet ACQUITY 430001486 ea. 25947<br />

Tube Assembly, SSV to In-line Filter nanoACQUITY 430001470 ea. 25948<br />

Tube Assembly, Transducer to Check Valve, BSM ACQUITY, nanoACQUITY 430001121 ea. 25949<br />

Tube Assembly, Transducer to Check Valve, QSM ACQUITY 430002357 ea. 25950<br />

Tube Assembly, SSV to I2V ACQUITY 430001443 ea. 25941<br />

Head Plunger Seal Kit ACQUITY, nanoACQUITY 700002599 kit 26428<br />

Wash Seal ACQUITY, nanoACQUITY 700002598 2-pk. 26429<br />

Pump O-Ring ACQUITY, nanoACQUITY WAT076152 ea. 25951<br />

Sapphire Plungers ACQUITY, nanoACQUITY 700002600 2-pk. 25958<br />

In-Line Filter Assembly, Stainless Steel Frit ACQUITY, nanoACQUITY 289003547 ea. 25952<br />

Filter Frit Cartridge, Stainless Steel ACQUITY 700002913 ea. 25953<br />

Solvent Bottle Filters ACQUITY 700003616 7-pk. 25954<br />

Primary Check Valve ACQUITY, nanoACQUITY 700002596 2-pk. 25955<br />

Accumulator Check Valve (Double Ball & Seat) ACQUITY, nanoACQUITY 700002968 2-pk. 25956<br />

I2 Check Valve Cartridge ACQUITY 700005165 ea. 25957<br />

25944<br />

25953<br />

25955<br />

NEW! High-Quality Lab<br />

Glassware at an Inviting Price<br />

• Kuderna-Danish Evaporator, Snyder<br />

Columns <strong>and</strong> Concentrator Tubes<br />

• Soxhlet Extraction Apparatus<br />

• Erlenmeyer <strong>and</strong> Class A Volumetric Flasks<br />

Buy today at www.restek.com/glassware<br />

• Auto-Zero <strong>and</strong> Squeeze-O-Matic Burets<br />

• Separatory Funnels<br />

• Repeating Pipettes<br />

• Impingers<br />

4<br />

the visit LC www.restek.com accessories you need for all are your at www.restek.com/LCacc<br />

chromatography needs


LC Accessories<br />

EXP ® Fittings<br />

coupler<br />

Reusable fittings for easy,<br />

yet reliable HPLC & UHPLC connections<br />

• H<strong>and</strong>-tight fitting style achieves effortless HPLC seals—no tools needed!<br />

• Both h<strong>and</strong>-tight <strong>and</strong> hex-head styles wrench-tighten for reliable UHPLC use.<br />

• Patented ferrule can be installed repeatedly without compromising high-pressure seal.<br />

• Hybrid design combines the durability of titanium with the sealing ability of PEEK.<br />

• Cutting-edge system provides ZDV (zero dead volume) connection<br />

to any 10-32 female port.<br />

• Compatible with 1 /16" PEEK <strong>and</strong> stainless steel tubing.<br />

www.restek.com/exp<br />

hex-head<br />

h<strong>and</strong>-tight<br />

Simplify Routine<br />

LC Maintenance With<br />

These Convenient Kits<br />

• Significant savings over instrument manufacturer prices.<br />

• High-quality components in every kit.<br />

• Wide range of options for HPLC systems <strong>and</strong> pumps.<br />

Save on<br />

Detector<br />

Lamps<br />

25145<br />

For a complete selection, visit<br />

www.restek.com/LC-Maintenance<br />

25259<br />

For a complete<br />

listing of lamps<br />

grouped by<br />

manufacturer, visit<br />

www.restek.com/LCLamps<br />

innovative chromatography products<br />

5


High Capacity TO-Clean Canister Cleaning<br />

System Improves Lab Efficiency<br />

One-year<br />

limited<br />

warranty!<br />

Dimensions:<br />

44"H x 48"W<br />

x 27"D<br />

Weight:<br />

525 lb<br />

Easily Create Custom Cleaning Programs: Create up to ten<br />

different methods using the on-board touch screen controller.<br />

Define the number of cycles, pressure, <strong>and</strong> soak times, then save<br />

the method for later use. Ensures consistent procedures are<br />

followed <strong>and</strong> makes operation as simple as pressing “start.”<br />

Ensure Performance with Easy, On-Board Diagnostics: With<br />

embedded diagnostic software, you can check for leaks <strong>and</strong> test<br />

valve operation at the touch of a button. Quick <strong>and</strong> easy system<br />

verification ensures effective cleaning.<br />

Oven Control at Your Fingertips: Isothermal oven cleans both<br />

canisters <strong>and</strong> valves faster <strong>and</strong> more completely than a heating<br />

b<strong>and</strong> system. Temperature is adjustable up to 110 °C.<br />

Cut Cleaning Time in Half: The high capacity interior holds twice as many canisters as similar models, which<br />

lets you finish cleaning faster. EPA Method TO-14A/15 compliant unit holds up to twelve 6-liter or twenty-four<br />

1-liter canisters.<br />

Air Canisters for VOC Monitoring<br />

SilcoCan® & TO-Can® Air Monitoring Canisters<br />

TO-Can® Canisters:<br />

• Proprietary electropolished surface maintains<br />

compound stability.<br />

• Ideal for TO-14A <strong>and</strong> TO-15, ASTM D5466, <strong>and</strong> other<br />

VOC methods.<br />

SilcoCan® Canisters:<br />

• Siltek® passivation offers unsurpassed inertness.<br />

• Especially suited for low-level reactive sulfur (1–20 ppb)<br />

<strong>and</strong> brominated compounds.<br />

6<br />

shop for air canisters, canister cleaners & more at www.restek.com/air


Air Sampling<br />

Meet 2 nd Source Gas St<strong>and</strong>ard<br />

Requirements With 1 Order<br />

Restek features a wide selection of high-quality air monitoring gas<br />

calibration st<strong>and</strong>ards. Each mix is independently manufactured for<br />

Restek by both Spectra/Linde <strong>and</strong> Scott/Air Liquide, enabling you to<br />

purchase your gas st<strong>and</strong>ards from 2 separate sources with the<br />

convenience of placing just 1 order!<br />

• Each mix is produced gravimetrically using NIST-traceable<br />

weights for improved accuracy.<br />

• Unique serial numbers <strong>and</strong> certificates of analysis give you<br />

confidence in cylinder contents <strong>and</strong> your final data.<br />

• All TO-14A <strong>and</strong> TO-15 gas st<strong>and</strong>ards feature at least<br />

12-month stability.<br />

• Recertification is available directly from the suppliers.<br />

• Disposable cylinders save rental <strong>and</strong> demurrage fees.<br />

• Drop-shipment by the manufacturer ensures fast<br />

delivery <strong>and</strong> maximum shelf life.<br />

For more details, ordering information, <strong>and</strong> full<br />

component lists, go to www.restek.com/2ndsource<br />

Cylinders available<br />

with or without<br />

Pi mark!<br />

Tedlar® Sample Bags Available!<br />

• Find the bags you need—we offer sizes from 0.5 liters to 100 liters.<br />

• Unique all-in-one septum <strong>and</strong> valve fitting make these lightweight<br />

<strong>and</strong> easy to use.<br />

• Polypropylene or stainless steel valve options.<br />

• Both valves conveniently connect to ³⁄16" ID PTFE tubing.<br />

Also Available<br />

PTFE Faced Silicone<br />

Replacement Septa<br />

(cat.# 22104) <strong>and</strong><br />

Multilayer<br />

Foil Bags<br />

Polypropylene Valve Stainless Steel Valve<br />

Description qty. cat.# cat.#<br />

0.5 L 6" x 6" 10-pk. 22049 22038<br />

1 L 7" x 7" 10-pk. 22050 22039<br />

3 L 9.5" x 10" 10-pk. 22051 22040<br />

5 L 12" x 12.5" 10-pk. 22052 22041<br />

10 L 11.75" x 22" 10-pk. 22053 22042<br />

12 L 13" x 24" 10-pk. 22054 22043<br />

25 L 17.5" x 24" 5-pk. 22055 22044<br />

40 L 24" x 24.25" 5-pk. 22056 22045<br />

80 L 28.25" x 30.5" 5-pk. 22057 22046<br />

100 L 28" x 36" 3-pk. 22058 22047<br />

innovative chromatography products<br />

7


NEW GC Columns for PAH Analysis<br />

Rxi®-PAH Columns Resolve Important Isobaric Polycyclic Aromatic<br />

Hydrocarbons for Food Safety & Environmental Methods<br />

• Separation of all EFSA PAH4 compounds: benz[a]anthracene, chrysene,<br />

benzo[b]fluoranthene, <strong>and</strong> benzo[a]pyrene.<br />

• Best resolution of chrysene from interfering PAHs, triphenylene<br />

<strong>and</strong> cyclopenta[cd]pyrene.<br />

• Complete separation of benzo [b], [k], [j], <strong>and</strong> [a] fluoranthenes.<br />

• 360 °C thermal stability allows analysis of low volatility dibenzo pyrenes.<br />

Whether you want more resolution or faster analysis times, new Rxi®-PAH columns have<br />

the selectivity <strong>and</strong> efficiency you need. Choose the configuration that is best for your separation.<br />

Cat.# Length ID df Description<br />

49316 40 m 0.18 mm 0.07 μm Narrow inside diameter, thinner film, faster analysis, excellent separation of important PAHs,<br />

less sample loading capacity<br />

49317 60 m 0.25 mm 0.10 μm 0.25 mm inner diameter, better sample loading capacity, highest resolution of important PAHs,<br />

longer analysis than 0.18 mm column, thin film allows elution of dibenzo pyrenes<br />

49318 30 m 0.25 mm 0.10 μm 0.25 mm inside diameter, better sample loading capacity, faster analysis time<br />

than 60 m column, adequate resolution of important PAHs, lower cost column<br />

Order<br />

yours today at<br />

www.restek.com/<br />

rxi-pah<br />

A 40 m x 0.18 mm x 0.07 μm Rxi®-PAH column produces excellent resolution of critical peaks in less than 33 minutes!<br />

1<br />

2<br />

3<br />

4<br />

5<br />

7<br />

6<br />

8<br />

benz[a]anthracene<br />

triphenylene chrysene<br />

17<br />

13 14 16<br />

9<br />

12<br />

15.20 15.80 16.40 17.00 17.60<br />

10 11<br />

15<br />

12<br />

13<br />

Separate <strong>and</strong> accurately<br />

quantify EFSA PAH4<br />

priority compounds.<br />

22.40 22.80 23.20 23.60<br />

14<br />

15<br />

17<br />

16<br />

18<br />

benzo [b], [k], [j], & [a]<br />

fluoranthenes<br />

20<br />

19<br />

GC_FF1223<br />

21 21<br />

18<br />

20<br />

19<br />

21<br />

benzo[a]<br />

pyrene<br />

22 23 24<br />

26.40 26.80 27.20 27.60 28.00 28.40<br />

80<br />

31<br />

26,27,28<br />

25<br />

25<br />

27 27<br />

26<br />

29 30<br />

28<br />

31 31<br />

29 30 32 33<br />

4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00<br />

Tim<br />

Complete analytical conditions are available at www.restek.com by searching for GC_FF1223<br />

Time (min)<br />

3435<br />

32 32<br />

36<br />

Peaks<br />

1. Naphthalene<br />

2. Biphenyl<br />

3. Acenaphthylene<br />

4. Acenaphthene<br />

5. Fluorene<br />

6. Dibenzothiophene<br />

7. Phenanthrene<br />

8. Anthracene<br />

9. 4H-Cyclopenta[def]<br />

phenanthrene<br />

10. Fluoranthene<br />

11. Pyrene<br />

12. Benzo[ghi]fluoranthene<br />

13. Benzo[c]phenanthrene<br />

14. Benz[a]anthracene<br />

15. Cyclopenta[cd]pyrene<br />

16. Triphenylene<br />

17. Chrysene<br />

18. Benzo[b]fluoranthene<br />

19. Benzo[k]fluoranthene<br />

20. Benzo[ j]fluoranthene<br />

21. Benzo[a]fluoranthene<br />

22. Benzo[e]pyrene<br />

23. Benzo[a]pyrene<br />

24. Perylene<br />

25. Dibenz[a,j]anthracene<br />

26. Dibenz[a,c]anthracene<br />

27. Indeno[1,2,3-cd]pyrene<br />

28. Dibenz[a,h]anthracene<br />

29. Benzo[b]chrysene<br />

30. Picene<br />

31. Benzo[ghi]perylene<br />

32. Anthanthrene<br />

33. Dibenzo[b,k]<br />

fluoranthene<br />

34. Dibenzo[a,e]pyrene<br />

35. Coronene<br />

36. Dibenzo[a,h]pyrene<br />

8 visit www.restek.com for all your chromatography needs


Restek® Guards Capture Harmful<br />

Contaminants Before They Reach<br />

Your Analytical GC Column<br />

GC Columns<br />

• Capture non-volatile sample residue that can cause bleed, tailing peaks, loss of response, <strong>and</strong><br />

other performance issues if it reaches your analytical column.<br />

• Extend analytical column life <strong>and</strong> reduce downtime by helping eliminate the need for<br />

column trimming.<br />

• Batch tested to ensure high inertness; chromatogram included.<br />

• Available in fused silica or metal MXT® tubing.<br />

• Match your Restek® guard column to your application <strong>and</strong> analytical column for optimum<br />

performance.<br />

Guard<br />

Column<br />

Maximum<br />

Temperature<br />

Tubing<br />

Availability<br />

Recommended<br />

Applications<br />

Recommended<br />

Analytical Columns<br />

Rxi® 360 °C Fused Silica Active compounds Rxi®<br />

Intermediate-Polarity<br />

Deactivated<br />

Hydroguard®<br />

Water-Resistant<br />

325 °C<br />

325 °C<br />

Fused Silica &<br />

Metal MXT®<br />

Fused Silica &<br />

Metal MXT®<br />

Wide range of<br />

compounds & solvents<br />

Samples in<br />

water-based matrix<br />

Base-Deactivated 315 °C Fused Silica Basic compounds<br />

Polar-Deactivated 280 °C Fused Silica<br />

Polar compounds<br />

& solvents<br />

Rtx® & MXT®<br />

Rxi®, Rtx® & MXT®<br />

Rtx®-5 Amine,<br />

Rtx®-35 Amine,<br />

Rtx® Volatile Amine<br />

& Stabilwax® DB<br />

Stabilwax®,<br />

Stabilwax® DA<br />

& Rtx®-Wax<br />

Visit www.restek.com/GCguards for a<br />

complete listing of dimensions <strong>and</strong> specifications<br />

innovative chromatography products 9


7 Pesticide Methods on 1 Column Pair!<br />

Analyze Pesticides, PCBs, Herbicides, <strong>and</strong> More on a Single Column Set<br />

Get improved resolution, faster analyses, <strong>and</strong> less downtime with an Rtx®-CLPesticides <strong>and</strong><br />

Rtx®-CLPesticides2 column set for multiple GC-ECD methods. Instead of changing columns between<br />

methods*, you can save time by using the same column set to analyze:<br />

Chlorinated pesticides • PCBs • Herbicides • Haloacetic acids • Other halogenated compounds<br />

Rtx®-CLPesticides columns feature very low bleed for the<br />

highest sensitivity <strong>and</strong> offer faster analysis time with full<br />

separation of chlorinated pesticides.<br />

Organochlorine Pesticide Mix AB #2<br />

on Rtx®-CLPesticides <strong>and</strong><br />

Rtx®-CLPesticides2<br />

(0.32 mm ID column set)<br />

Rtx®-CLPesticides<br />

Buy a Column Kit & Save!<br />

Rtx®-CLPesticides Column Kit (0.25 mm ID)<br />

Rtx-CLPesticides Kit (0.25 mm ID) cat.# 11199 (kit)<br />

SAVE<br />

with our Rtx®-<br />

CLPesticides<br />

Kits<br />

Analytical columns, guard columns, <strong>and</strong> connectors<br />

are available separately, but you can save big just by<br />

ordering one of our recommended combinations packed<br />

in a convenient, pre-built kit!<br />

Includes:<br />

cat.#<br />

30 m, 0.25 mm ID, 0.25 μm Rtx-CLPesticides Column Column 11123<br />

30 m, 0.25 mm ID, 0.20 μm Rtx-CLPesticides2 Column Column 11323<br />

Universal Angled “Y” Press-Tight Connector , Deactivated 20403-261<br />

5 m, 0.25 mm ID Siltek Guard Column 10026<br />

0.32 mm ID column analysis<br />

performed in less than 7 minutes!<br />

Rtx®-CLPesticides2<br />

GC_EV00933<br />

Rtx®-CLPesticides Column Kit (0.32 mm ID)<br />

Rtx-CLPesticides Kit (0.32 mm ID) cat.# 11196 (kit)<br />

Includes:<br />

cat.#<br />

30 m, 0.32 mm ID, 0.32 μm Rtx-CLPesticides Column Column 11141<br />

30 m, 0.32 mm ID, 0.25 μm Rtx-CLPesticides2 Column Column 11324<br />

Universal Angled “Y” Press-Tight Connector , Deactivated 20403-261<br />

5 m, 0.32 mm ID Siltek Guard Column 10027<br />

Rtx®-CLPesticides Column Kit (0.53 mm ID)<br />

Rtx-CLPesticides Kit (0.53 mm ID) cat.# 11197 (kit)<br />

Includes:<br />

cat.#<br />

30 m, 0.53 mm ID, 0.50 μm Rtx-CLPesticides Column Column 11140<br />

30 m, 0.53 mm ID, 0.42 μm Rtx-CLPesticides2 Column Column 11340<br />

Universal Angled “Y” Press-Tight Connector , Deactivated 20403-261<br />

5 m, 0.53 mm ID IP Deactivated Guard Column 10045<br />

GC_EV00933A<br />

Complete analytical conditions are available at www.restek.com by searching for GC_EV00933<br />

(Note: Columns are not preconnected in this kit.)<br />

* NOTE: If analyzing trace-level pesticide samples following dirty or derivatized samples,<br />

Restek recommends first performing st<strong>and</strong>ard inlet maintenance, such as trimming the guard<br />

column <strong>and</strong> changing the inlet liner, seal, <strong>and</strong> septum.<br />

10<br />

learn more at www.restek.com/RtxCLP7


GC Columns<br />

Separate Permanent Gases With Restek ®<br />

Molecular Sieve 5A PLOT Columns<br />

Our revolutionary molecular sieve<br />

5A PLOT columns are designed for<br />

efficient separation of Ar/O2 <strong>and</strong> H2/He<br />

at or above ambient temperature (see<br />

chromatogram) as well as CH4, C2H6, <strong>and</strong><br />

CO. These columns also are an excellent<br />

choice for rapid separation of gases in<br />

refinery or natural gas.<br />

Rt®-Msieve 5A Columns (fused silica PLOT)<br />

ID df temp. limits 15-Meter 30-Meter<br />

0.25 mm 20 μm to 300 °C 19773<br />

0.32 mm 30 μm to 300 °C 19720 19722<br />

0.53 mm 50 μm to 300 °C 19721 19723<br />

Separation of Argon/Oxygen <strong>and</strong><br />

Other Permanent Gases on Rt®-Msieve 5A<br />

Conc.<br />

Peaks (μg/mL)<br />

1. Hydrogen 40<br />

2. Argon 30<br />

3. Oxygen 50<br />

4. Nitrogen 50<br />

5. Methane 40<br />

6. Carbon<br />

monoxide 50<br />

Argon<br />

resolved<br />

from<br />

oxygen.<br />

2<br />

3 4<br />

Excellent peak shape<br />

for carbon monoxide.<br />

0 2 4 6 8 10 Time(min)<br />

For larger view <strong>and</strong> conditions, visit www.restek.com <strong>and</strong> enter<br />

chromatogram GC_PC00898 in the search function.<br />

5<br />

GC_PC00898<br />

6<br />

MXT®-Msieve 5A Columns (metal MXT PLOT)<br />

3.5" coil<br />

7" diameter<br />

11-pin cage<br />

3.5" coil<br />

7" diameter<br />

11-pin cage<br />

ID df (μm) temp. limits 15-Meter 15-Meter 30-Meter 30-Meter<br />

0.25 mm 20 μm to 300 °C 79717-273 79717<br />

0.53 mm 50 μm to 300 °C 79723-273 79723<br />

Choose<br />

fused silica or<br />

metal MXT®<br />

tubing!<br />

Restek ® Porous Polymer PLOT Columns —<br />

The New Benchmark For Performance!<br />

• Stabilized particle layers improve robustness <strong>and</strong><br />

reproducibility of retention <strong>and</strong> flow.<br />

• Fully compatible with valve switching <strong>and</strong> Deans<br />

switching systems.<br />

• Highly efficient, reproducible analyses; ideal for<br />

permanent gases, solvents, <strong>and</strong> hydrocarbons.<br />

• Innovative manufacturing procedure reduces particle<br />

generation <strong>and</strong> improves performance.<br />

Available In:<br />

Fused Silica Rt® Column Solid Phases:<br />

Rt®-Q-BOND Rt®-S-BOND<br />

Rt®-QS-BOND Rt®-U-BOND<br />

Metal MXT® Column Solid Phases:<br />

MXT®-Q-BOND MXT®-S-BOND<br />

Restek® porous polymer<br />

PLOT columns cover a<br />

wide range of polarities<br />

Q-BOND<br />

QS-BOND<br />

S-BOND<br />

U-BOND<br />

Least<br />

Polar<br />

Most<br />

Polar<br />

Order your PLOT columns today at www.restek.com/PLOT<br />

innovative chromatography products<br />

11


Upgrade the FID Jets in your Agilent GCs<br />

Which FID Jet Should I Use?<br />

There are two FID jet<br />

configurations for Agilent GCs.<br />

The longer “adaptable” jet fits<br />

both 5890 <strong>and</strong> 6890 GCs, <strong>and</strong> can be<br />

used with capillary or packed columns.<br />

The shorter “dedicated” jet is for the FID<br />

in the 6890/7890 GC that is designed<br />

only for use with capillary columns.<br />

tech<br />

tip<br />

St<strong>and</strong>ard Version<br />

• Threads specially coated for easy installation <strong>and</strong> removal.<br />

• Special processing ensures the highest degree of cleanliness.<br />

• Meets or exceeds original manufacturer's performance.<br />

High-Performance Version—Siltek® Treated<br />

• Similar to the st<strong>and</strong>ard version, but Siltek® treated.<br />

• Extremely inert, for use with active compounds.<br />

Capillary Adaptable FID Replacement Jet for Agilent 5890/6890/6850 GCs<br />

Engineered with a fluted tip to guide the capillary column into the jet.<br />

Description<br />

Similar to<br />

Agilent part # qty. cat.# qty. cat.#<br />

St<strong>and</strong>ard, 0.011-Inch ID Tip 19244-80560 ea. 20670 3-pk.20671<br />

High-Performance Siltek Treated,<br />

0.011-Inch ID Tip<br />

19244-80560 ea.20672 3-pk.20673<br />

Capillary Dedicated FID Replacement Jet for Agilent 6890/6850/7890 GCs<br />

Description<br />

Similar to<br />

Agilent part # qty. cat.# qty. cat.#<br />

St<strong>and</strong>ard, 0.011-Inch ID Tip G1531-80560 ea. 21621 3-pk.21682<br />

High-Performance Siltek Treated,<br />

0.011-Inch ID Tip<br />

G1531-80560 ea.21620 3-pk.21683<br />

High-Temperature, 0.018-Inch ID Tip G1531-80620 ea. 23078 3-pk.23079<br />

Easily Remove <strong>and</strong> Install FID Jets<br />

With Our FID Jet Removal Tool<br />

FID Jet Removal Tool for Agilent 5890/6890/6850/7890 FIDs<br />

• Securely grips jet in socket for easy removal or installation.<br />

• Unique, ergonomic h<strong>and</strong>le—easy to hold.<br />

Slip tool over FID jet... ...loosen jet... ...<strong>and</strong> remove.<br />

Description qty. cat.#<br />

FID Jet Removal Tool for Agilent 5890/6890/6850/7890 FIDs ea. 22328<br />

FID flow measuring adaptor also available! Search for cat.# 21000 at www.restek.com<br />

12<br />

visit www.restek.com for all your chromatography needs


GC Accessories<br />

Switch to Precision-Molded,<br />

Low-Bleed Septa From Restek<br />

• Precision molding assures<br />

consistent, accurate fit.<br />

• Preconditioned <strong>and</strong> ready to use.<br />

• Packaged in ultra-clean blister packs**.<br />

Restek® Thermolite® Septa<br />

• Usable to 340 °C inlet<br />

temperature*.<br />

• Excellent puncturability.<br />

• A Restek exclusive!<br />

Septum Diameter 50-pk. 100-pk.<br />

5 mm ( 3 /16") 27121 27122<br />

6 mm ( 1 /4") 27124 27125<br />

7 mm 27127 27128<br />

8 mm 27130 27131<br />

9 mm 27133 27134<br />

9.5 mm ( 3 /8") 27136 27137<br />

10 mm 27139 27140<br />

11 mm ( 7 /16") 27142 27143<br />

11.5 mm 27145 27146<br />

12.7 mm ( 1 /2") 27148 27149<br />

17 mm 27151 27152<br />

Shimadzu <strong>Plug</strong> 27154 27155<br />

Premium Non-Stick BTO® Septa<br />

• Usable to 400 °C inlet temperature*.<br />

• New plasma coating eliminates sticking in the injection port.<br />

• Partial predrilled CenterGuide design.<br />

• Each batch GC-FID tested.<br />

• Bleed <strong>and</strong> temperature optimized; ideal<br />

for dem<strong>and</strong>ing GC <strong>and</strong> GC-MS applications.<br />

NEW!<br />

Septum Diameter 50-pk. 100-pk.<br />

5 mm CenterGuide 27082 27083<br />

9 mm CenterGuide 27084 27085<br />

9.5 mm ( 3 /8") 27086 27087<br />

10 mm 27088 27089<br />

11 mm ( 7 /16") CenterGuide 27090 27091<br />

11.5 mm CenterGuide 27092 27093<br />

12.7 mm ( 1 /2") CenterGuide 27094 27095<br />

17 mm CenterGuide 27096 27097<br />

Shimadzu <strong>Plug</strong> 27098 27099<br />

Note: Due to differences in inlet design, the actual septum temperature for a given inlet setpoint can vary by manufacturer. Restek recommends using only BTO® septa in Thermo TRACE <strong>and</strong><br />

Focus GCs. *For 17 mm inlets, the maximum temperature is 330 °C. For all injectors, minimum recommended operating temperature for BTO® septa is 250 °C. **12.7 mm <strong>and</strong> 17 mm septa<br />

packaged in precleaned glass jars.<br />

Measure<br />

your old<br />

septum here<br />

(size in mm)<br />

5 7 9 9.5 10 11 11.5 12.7 17<br />

View our full selection at<br />

www.restek.com/septa<br />

Never Use a Washer Again!<br />

Our patented dual Vespel® ring inlet seal greatly improves injection port performance—<br />

it stays sealed, even after repeated temperature cycles, without retightening the<br />

reducing nut! This seal features two soft Vespel® rings that eliminate the<br />

need for a washer <strong>and</strong> need very little torque to make a leak-tight seal.<br />

0.8 mm ID Dual Vespel Ring Inlet Seal 2-pk. 10-pk. 50-pk.<br />

Gold-Plated 21240 21241 23418<br />

Siltek-Treated 21242 21243 23419<br />

Stainless Steel 21238 21239 23420<br />

1.2 mm ID Dual Vespel Ring Inlet Seal 2-pk. 10-pk.<br />

Gold-Plated 21246 21247<br />

Siltek-Treated 21248 21249<br />

Stainless Steel 21244 21245<br />

Learn more at www.restek.com/dvr<br />

Save<br />

by ordering<br />

50-packs!<br />

restek<br />

innovation!<br />

innovative chromatography products<br />

13


Get Your GC-MS Essentials Here!<br />

GC-MS<br />

Interface<br />

Transfer<br />

Line<br />

EZ<br />

No-Vent®<br />

Connector<br />

Capillary<br />

Ferrule<br />

Capillary<br />

Nut<br />

Transfer<br />

Line<br />

Ferrule<br />

Capillary<br />

Column<br />

EZ No-Vent®<br />

GC Column-Mass<br />

Spectrometer Connector<br />

for Agilent GCs with 5971/5972, 5973,<br />

or 5975 GC-MS<br />

• Change GC-MS columns in minutes<br />

without venting—100 μm transfer<br />

line maintains vacuum <strong>and</strong><br />

eliminates the need to vent.<br />

• Easy to install <strong>and</strong> maintain—no<br />

special tools or plumbing required.<br />

• Gold-plated body for inertness.<br />

• High-temperature polyimide<br />

ferrules eliminate leaks at the<br />

problematic transfer line fitting.<br />

• Lower cost than other “no-vent”<br />

fittings.<br />

Description qty. cat.#<br />

EZ No-Vent Connector Kit<br />

includes: EZ No-Vent Connector, two 0.4 mm ID adaptor ferrules for<br />

capillary column, two 0.4 mm ID ferrules for transfer line, 100 μm<br />

kit 21323<br />

deactivated transfer line (3 ft.), column plug, column nut<br />

Replacement ferrules for connecting capillary column to EZ<br />

No-Vent Connector:<br />

0.4 mm (Polyimide)2-pk. 21015<br />

0.5 mm (Polyimide)2-pk. 21016<br />

Replacement Ferrules (polyimide) for connecting transfer line to<br />

EZ No-Vent connector: 0.4 mm ID<br />

2-pk. 21043<br />

Replacement 100 μm Deactivated Transfer Line 3 ft 21018<br />

Replacement EZ No-Vent Column Nut 20-pk. 23100<br />

Replacement EZ No-Vent <strong>Plug</strong> 5-pk. 23112<br />

Open-End Wrenches , 1<br />

/4" x 5 /16" 2-pk. 20110<br />

For other instrument-specific EZ No-Vent®<br />

connectors, visit www.restek.com<br />

Inl<strong>and</strong> 45 Pump Oil<br />

Recommended for most mass spectrometers.<br />

• Ease at cold start.<br />

• Low vapor pressure 10-7 torr.<br />

• Nontoxic <strong>and</strong> noncorrosive.<br />

• Compatible with buna-N, neoprene,<br />

<strong>and</strong> Viton® seals.<br />

• Optimum vacuum pump performance.<br />

• Lowest mass spectrometer background.<br />

• Recommended for optimum mass spec performance.<br />

Similar to<br />

Description<br />

Agilent part # qty. cat.#<br />

Inl<strong>and</strong> 45 Pump Oil 6040-0834 1 liter 24819<br />

ETP Electron Multipliers<br />

for Mass Spectrometry<br />

• Air stable.<br />

• 2-year shelf life guarantee.<br />

• Discrete dynode design extends operating life.<br />

Description qty. cat.#<br />

Electron Multipliers for Agilent GC-MS <strong>and</strong> LC-MS<br />

For Agilent 5970 GC-MS ea. 23072<br />

For Agilent 5971, 5972, GC GC-MS ea. 23073<br />

For Agilent 5973 & 5975 GC-MS (includes mount for initial installation)*†<br />

ea. 23074<br />

For Agilent 5973 & 5975 GC-MS <strong>and</strong> LC-MSD (Replacement Multiplier)*†<br />

ea. 23075<br />

Other ETP Electron Multipliers are available upon request. Call us or contact your Restek®<br />

representative if you do not see your instrument listed.<br />

MSD Source Nut<br />

• 1.2 mm nut bore permits easy removal of ferrules with a<br />

st<strong>and</strong>ard tapered-needle file (cat.# 20106).<br />

• Made of brass to prevent threadstripping<br />

on the transfer line.<br />

• Design enhances ease of threading<br />

onto the transfer line <strong>and</strong> improves overall lifetime.<br />

Similar to<br />

Description<br />

Agilent part # qty. cat.#<br />

(Detector) MSD Source Nut 05988-20066 2-pk. 20643<br />

GC-MS Cleaning Kit<br />

Poor sensitivity, loss of<br />

sensitivity at high masses,<br />

or high multiplier gain<br />

during an auto tune are<br />

all indicators that your<br />

mass spectrometer source may need to be cleaned. Restek<br />

has assembled all of the necessary components for cleaning<br />

<strong>and</strong> polishing your ion source.<br />

Ion Source Cleaning Powder<br />

27194<br />

Description qty. cat.#<br />

Mass Spec Cleaning Kit with Dremel Tool kit 27194<br />

Mass Spec Cleaning Kit without Dremel Tool kit 27195<br />

Mass Spec Cleaning Kit Replacement Parts Kit<br />

Includes: cloths, micro mesh sheets, small <strong>and</strong> large gloves<br />

kit 27196<br />

Use this aluminum oxide powder to clean<br />

surfaces that contact the sample or ion beam<br />

when you encounter poor sensitivity <strong>and</strong><br />

inadequate abundances at high masses.<br />

Similar to<br />

Description<br />

Agilent part # qty. cat.#<br />

Ion Source Cleaning Powder 8660-0791 1 kg 22685<br />

14<br />

visit www.restek.com/gcacc for a full listing of GC accessories


GC Accessories<br />

Choose Screw-Thread Headspace Vials<br />

for Your Gerstel or CTC/LEAP Samplers<br />

• Compatible with Gerstel <strong>and</strong> CTC/LEAP Technologies headspace<br />

samplers when used with magnetic closures.<br />

Headspace Screw-Thread Vials (18 mm)<br />

Description Volume Color Dimensions 100-pk. 1000-pk.<br />

Headspace Vial 10 mL Clear 22 x 45 mm 23084 23085<br />

Headspace Vial 10 mL Amber 22 x 45 mm 23088 23089<br />

Headspace Vial 20 mL Clear 22 x 75 mm 23082 23083<br />

Headspace Vial 20 mL Amber 22 x 75 mm 23086 23087<br />

Caps not included (sold separately).<br />

18 mm Magnetic Screw-Thread Caps<br />

Description Septa Material 100-pk. 1000-pk.<br />

Magnetic Caps <strong>and</strong> Septa PTFE/Silicone 23090 23091<br />

Magnetic Caps <strong>and</strong> Septa PTFE/Silicone for SPME 23092 23093<br />

Magnetic Caps <strong>and</strong> Septa PTFE/Red Chlorobutyl 23094 23095<br />

Get The Security of a Crimp-Top Vial<br />

With the <strong>Convenience</strong> of a Screw-Thread<br />

• Shorter screw cap allows the robotic autosampler to function properly.<br />

• Wider opening prevents syringe problems.<br />

• Dimensions are effectively identical to the crimp-top vial.<br />

2.0 mL, 9 mm Short-Cap, Screw-Thread Vials (vial only)<br />

Description Volume Color 100-pk. 1000-pk.<br />

Short-Cap Vial w/White Graduated Marking Spot 2.0 mL Clear 21140 21141<br />

Short-Cap Vial w/White Graduated Marking Spot 2.0 mL Amber 21142 21143<br />

Short-Cap Vial without Graduated Marking Spot 2.0 mL Clear 21154 21155<br />

2.0 mL, 9 mm Short-Cap, Screw-Vial Closures (Polypropylene, preassembled)<br />

Cap Color Liner Material 100-pk. 500-pk. 1,000-pk.<br />

Blue PTFE/Butyl Rubber 24473 — 24474<br />

Mixed PTFE/Butyl Rubber —24668 —<br />

Blue PTFE/Silicone 24485 —24486<br />

Green PTFE/Silicone 24487 —24488<br />

Yellow PTFE/Silicone 24493 — 24494<br />

Mixed PTFE/Silicone —24669 —<br />

Blue PTFE/Silicone/PTFE 24497 — 24498<br />

Black PTFE/Silicone/PTFE 24495 — 24496<br />

Natural PTFE/Silicone/PTFE 24501 —24502<br />

Red PTFE/Silicone/PTFE 24503 —24504<br />

Yellow PTFE/Silicone/PTFE 24505 —24506<br />

Mixed PTFE/Silicone/PTFE —24670 —<br />

23082 23084 23086 23088<br />

23090 23094<br />

21140<br />

Agilent Compatible!<br />

Ideal for Agilent 7673, 7683, 7693 & other autosamplers<br />

that process 12 x 32 mm crimp-top vials.<br />

24668<br />

Don’t Forget the Rack! 2.0 mL Sample Vial Racks<br />

• Racks feature alphanumeric indexing for easier vial identification.<br />

• Racks can be stacked for efficient storage.<br />

Description Capacity qty. cat.# qty. cat.#<br />

Polypropylene Storage Rack for 12 x 32 mm Vials 50 vials, 5 x 10 ea. 22856 5-pk. 22857<br />

Crimp-Top Vials Also Available<br />

innovative chromatography products 15


GC Columns<br />

Solid Phase Extraction Cartridges from Restek<br />

Proven Quality • Superior Cleanliness • Method-Specific Performance<br />

Available with the following sorbents:<br />

• Silica: Multipurpose<br />

• EPH Silica: Petroleum<br />

• Florisil® Adsorbent: Pesticides<br />

• CarboPrep® Adsorbent: Dirty Samples<br />

FREE samples available!<br />

Contact us or your local Restek® representative.<br />

Learn more at www.restek.com/resprep<br />

Perfect<br />

for pesticide<br />

analysis! Pair with<br />

Rtx®-CLPesticides Columns (page 10).<br />

Go Green!<br />

Help Save the Environment <strong>and</strong> Save Time in<br />

the Lab With Q-sep QuEChERS Products<br />

REDUCE:<br />

Easy-pour packets create far less waste<br />

than tubes of extraction salts.<br />

REUSE:<br />

Highly inert FEP centrifuge tubes are<br />

reusable indefinitely under normal use.<br />

RECYCLE:<br />

Packet boxes consist of at least 33% recycled<br />

cardboard <strong>and</strong> are 100% recyclable.<br />

Available for European EN 15662,<br />

AOAC 2007.01, <strong>and</strong> Original Unbuffered Methods.<br />

Visit www.restek.com/quechers for full product lists<br />

16 visit www.restek.com for all your chromatography needs


Sample Preparation<br />

Replacement Parts & Accessories<br />

for ASE ® Systems<br />

Including Models 100,<br />

150, 200, 300, <strong>and</strong> 350<br />

• Extraction Cell Parts<br />

• PEEK Washers<br />

• Collection Vials<br />

• O-Rings<br />

• Filters<br />

• Tools<br />

• And More!<br />

Order now at<br />

www.restek.com/ase<br />

Syringe Filters with Luer Lok Inlet<br />

• Luer lok inlet offers leak-tight syringe connection.<br />

• Variety of filter types, porosities, <strong>and</strong> diameters.<br />

• Color coded for easy identification.<br />

• Rugged polypropylene housing.<br />

• Autoclavable to 121 °C for 15 minutes.<br />

• Quantity break pricing for greater savings.<br />

View our exp<strong>and</strong>ed line at<br />

www.restek.com/filters<br />

innovative chromatography products<br />

17


Reference St<strong>and</strong>ards<br />

Detect <strong>and</strong> Quantify<br />

204 Pesticides of<br />

Global Concern by<br />

LC-MS/MS<br />

• Full kit of reference st<strong>and</strong>ards contains 204 compounds of interest, covering many<br />

LC-determined pesticides listed by government agencies; individual ampuls also sold separately.<br />

• Formulated <strong>and</strong> grouped for maximum shelf life <strong>and</strong> well-balanced chromatographic<br />

performance, even for early eluting compounds.<br />

• Quantitatively tested to confirm composition <strong>and</strong> long-term stability; detailed support<br />

documentation provided.<br />

• Optimized multi-residue pesticide method is offered free of charge; downloadable XLS file<br />

includes conditions <strong>and</strong> transition tables.<br />

• Ideal for a wide range of fruits, vegetables, <strong>and</strong> other commodities.<br />

• Restek is your complete supplier for world-class LC-MS/MS multi-residue pesticide analysis:<br />

reference <strong>and</strong> internal st<strong>and</strong>ards, Ultra <strong>and</strong> Pinnacle® DB LC columns, Q-sep QuEChERS sample<br />

prep products, accessories, <strong>and</strong> more!<br />

Learn more at www.restek.com/LC-multi-residue<br />

QUALITY<br />

9001 17025 Guide 34<br />

Accurately Determine Mineral Oil<br />

Hydrocarbons in Food Using Our<br />

New MOSH/MOAH St<strong>and</strong>ard<br />

• Developed specifically for using LC coupled with GC-FID to accurately determine<br />

hydrocarbons found in mineral oils, which can migrate from packaging into food.<br />

• 9-component mix contains non-interfering internal st<strong>and</strong>ards as well as both mineral oil<br />

saturated hydrocarbon (MOSH) <strong>and</strong> mineral oil aromatic hydrocarbon (MOAH) markers<br />

to correctly cut fractions.<br />

• Certified reference material (CRM) manufactured <strong>and</strong> QC-tested in Restek’s<br />

ISO-accredited labs satisfies your ISO requirements.<br />

• Restek is your complete supplier for world-class MOSH/MOAH analysis: reference<br />

st<strong>and</strong>ards, Allure® silica LC columns, Rxi®-5Sil MS GC columns, accessories, <strong>and</strong> more!<br />

Learn more at www.restek.com/mosh-moah<br />

LITY<br />

QUALITY<br />

U<br />

QUA<br />

T<br />

9001 17025 Guide 34<br />

18 visit ii www.restek.com for all your chromatography needs


Sample LC Preparation Columns<br />

Trident Direct Guard<br />

Column System<br />

Easy to Use, Low Dead Volume—The Ultimate<br />

Combination of <strong>Convenience</strong> <strong>and</strong> Column Protection<br />

XF<br />

fitting<br />

Trident Direct 10 mm guard<br />

cartridge holder with filter<br />

Cap<br />

Frit<br />

XG-XF<br />

Fitting<br />

Components<br />

Guard<br />

Cartridge<br />

Assembled<br />

PEEK<br />

Tip<br />

Installed onto column<br />

XG<br />

Fitting<br />

Unlike “one size fits all” column guards,<br />

the Trident Direct system gives you<br />

the power to select the right level of<br />

protection for your analysis. Choose<br />

from 3 levels of protection, guard<br />

cartridges in 4 dimensions, <strong>and</strong> a variety<br />

of bonded phases. A Trident Direct with<br />

its economical, leak-free cartridge design<br />

provides an unprecedented combination<br />

of convenience, economy, <strong>and</strong> reliability!<br />

Removable<br />

cap frits<br />

Double the<br />

Protection:<br />

Replacement guard<br />

cartridges can cost as much<br />

as an analytical column, so<br />

why not protect them, too?<br />

The removable cap frit in a Trident Direct helps<br />

prevent clogged cartridges to extend the life of<br />

your column, your cartridge, <strong>and</strong> your budget!<br />

Trident Direct provides 3 levels of protection<br />

25082<br />

High-pressure filter<br />

Protection against particulate matter.<br />

25083<br />

10 mm guard cartridge holder<br />

Protection against particulate matter <strong>and</strong><br />

irreversibly adsorbed compounds.<br />

25084<br />

10 mm guard cartridge holder with filter<br />

Double protection against particulate matter<br />

<strong>and</strong> irreversibly adsorbed compounds.<br />

Order yours at www.restek.com/tridentdirect<br />

innovative chromatography products 19


Dynamic Duo<br />

Restek’s Leak Detector <strong>and</strong><br />

ProFLOW 6000 Flowmeter<br />

An<br />

Unbeatable<br />

Combination!<br />

Protect your instrument <strong>and</strong> improve data quality<br />

with this powerful pair from Restek. Checking for leaks <strong>and</strong><br />

verifying flows before you start helps you avoid costly problems later.<br />

Description qty. cat.#<br />

Dynamic Duo Combo Pack (Restek Leak Detector <strong>and</strong> ProFLOW 6000 Flowmeter) kit 22654<br />

Related Products <strong>and</strong> Accessories<br />

Leak Detector With Hard-Sided Carrying Case <strong>and</strong> Universal Charger Set<br />

(U.S., UK, European, Australian)<br />

ea. 22655<br />

Small Probe Adaptor for Leak Detector ea. 22658<br />

Restek ProFLOW 6000 Electronic Flowmeter With Hard-Sided Carrying Case ea. 22656<br />

Soft-Sided Storage Case for Leak Detector or ProFLOW 6000 Flowmeter ea. 22657<br />

PATENTS & TRADEMARKS<br />

Restek® patents <strong>and</strong> trademarks are the property of Restek Corporation. (See www.restek.com/Patents-Trademarks for full list.) Other trademarks appearing in Restek® literature or on its website are<br />

the property of their respective owners. The Restek® registered trademarks used here are registered in the United States <strong>and</strong> may also be registered in other countries.<br />

Lit. Cat.# GNES1847-INT<br />

2013.2<br />

© 2013 Restek Corporation. All rights reserved. Printed in the U.S.A.<br />

U.S. • 110 Benner Circle • Bellefonte, PA 16823 • 1-814-353-1300 • 1-800-356-1688 • fax: 1-814-353-1309 • www.restek.com<br />

China • phone: +86-10-5629-6620 • fax: +86-10-5814-3980 • cn.restek.com<br />

France • phone: +33 (0)1 60 78 32 10 • fax: +33 (0)1 60 78 70 90 • www.restek.fr<br />

Germany • phone: +49 (0)6172 2797 0 • fax: +49 (0)6172 2797 77 • www.restekgmbh.de<br />

Irel<strong>and</strong> • phone: +44 (0)2890 814576 • fax: +44 (0)2890 814576 • e-mail: restekirel<strong>and</strong>@aol.com<br />

Italy • phone: +39-02-7610037 • fax: +39-02-70100100 • www.superchrom.it<br />

Japan • phone: +81 (3)6459 0025 • fax: +81 (3)6459 0025 • e-mail: restekjapan@restek.com<br />

UK • phone: +44 (0)1494 563377 • fax: +44 (0)1494 564990 • www.thamesrestek.co.uk<br />

20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!