Must-Have Solutions for Your Lab 2013.2<br />
Reliable Performance.<br />
Unbeatable Price.<br />
<strong>Plug</strong>-<strong>and</strong>-<strong>Play</strong> <strong>Convenience</strong>.<br />
Turn to Genuine Restek® Replacement Parts<br />
for your Waters ACQUITY UPLC® systems.<br />
See page 4 for details.<br />
Free posters!<br />
Request yours today<br />
www.restek.com/posters<br />
What’s New?<br />
Restek® Parts for Waters<br />
ACQUITY UPLC® Systems ......................................................4<br />
Reusable EXP® Fittings<br />
for HPLC & UHPLC ....................................................................5<br />
Rxi®-PAH Columns ...................................................................8<br />
Simplifying Column Selection<br />
ASE® 150/350 Replacement Parts ................................... 17<br />
LC-MS/MS Multi-Residue<br />
Pesticide St<strong>and</strong>ards Kit ....................................................... 18<br />
MOSH/MOAH Reference St<strong>and</strong>ards ............................... 18<br />
New & Improved Leak Detector ...................................... 20<br />
GC Troubleshooting Tips<br />
Innovative Chromatography Products www.restek.com • 1-800-356-1688 • 1-814-353-1300
Keep It Clean!<br />
Protect Your Instrument, Column, <strong>and</strong><br />
Budget With Restek® LC Filtration Products<br />
Mobile Phase Management<br />
www.restek.com/MobilePhaseAcc<br />
Bluestem Glass Solvent Filter<br />
• Filters particulates <strong>and</strong> microbial growth out of solvents to extend the life<br />
of columns <strong>and</strong> pump seals.<br />
• 15 μm borosilicate glass frit sits lower than conventional glass filters to<br />
draw more mobile phase from each bottle.<br />
• Blue stem allows instant visual confirmation of upright filter orientation.<br />
Description qty. cat.#<br />
Glass Solvent Filter, 15 μm frit ea. 26431<br />
Hub-Cap Filter Kit<br />
• Transfers <strong>and</strong> filters mobile phase in one step.<br />
• Includes bottle adapter, filter, fittings, tubing, <strong>and</strong> more.<br />
• Fit 4 L or Wheaton bottles; adapter for GL-45 bottles available.<br />
Description qty. cat.#<br />
Hub-Cap Filter Kit for 4 L or Wheaton bottles kit 26395<br />
Replacement Parts qty. cat.#<br />
Polypropylene Membrane Filters, 47 mm, 0.45 μm 100-pk. 26396<br />
Polypropylene Membrane Filters, 47 mm, 0.22 μm 100-pk. 26397<br />
Nylon Membrane Filters, 47 mm, 0.45 μm 100-pk. 26398<br />
Nylon Membrane Filters, 47 mm, 0.22 μm 100-pk. 26399<br />
Hub-Cap Filter Hose Barb ea. 25925<br />
Sample Preparation<br />
www.restek.com/singlestep<br />
Thomson SINGLE StEP® Filter Vials<br />
• Filter samples quickly <strong>and</strong> easily<br />
with a squeeze.<br />
• Color-coded for easy identification.<br />
• Fit most st<strong>and</strong>ard 12x32 mm autosamplers.<br />
Porosity Color qty. cat.#<br />
Nylon<br />
0.2 μm black cap 100-pk. 25891<br />
0.45 μm pink cap 100-pk. 25892<br />
PES (polyethersulfone)<br />
0.2 μm grey cap 100-pk. 25897<br />
0.45 μm orange cap 100-pk. 25898<br />
Patent No. 7,790,117<br />
Porosity Color qty. cat.#<br />
PTFE (polytetrafluoroethylene)<br />
0.2 μm green cap 100-pk. 25893<br />
0.45 μm blue cap 100-pk. 25894<br />
PVDF (polyvinyldifluoride)<br />
0.2 μm red cap 100-pk. 25895<br />
0.45 μm yellow cap 100-pk. 25896<br />
2<br />
visit www.restek.com for all your chromatography needs
LC Accessories<br />
Pump Maintenance<br />
www.restek.com/LCInstParts-Agilent<br />
Frits (PTFE) for Agilent HPLC Systems<br />
• Fits Agilent HPLC 1050, 1100, <strong>and</strong> 1200 systems.<br />
• Similar to Agilent #01018-22707.<br />
Description Model # Similar to Agilent part # qty. cat.#<br />
Frits, PTFE 1050, 1100, 1200 01018-22707 5-pk. 25466<br />
Replacement parts available for all major manufacturers’ instruments.<br />
See www.restek.com/LCacc<br />
Column Protection<br />
www.restek.com/LCguard<br />
UHPLC: UltraShield PreColumn Filter<br />
• Cost-effectively protects UHPLC systems.<br />
• Reliably extends column lifetime.<br />
• Seals leak-tight to 15,000 psi (1,034 bar).<br />
Description qty. cat.#<br />
UltraShield UHPLC PreColumn Filter ea. 24995<br />
UltraShield UHPLC PreColumn Filter 5-pk. 24996<br />
UltraShield UHPLC PreColumn Filter 10-pk. 24997<br />
24995<br />
HPLC: Trident Direct Guard Cartridge System<br />
• Offers three levels of protection: filter alone, guard alone, or<br />
filter <strong>and</strong> guard together.<br />
• Attaches to any HPLC column with CPI- or Waters-style end.*<br />
• Accepts Restek® guard cartridges in a variety of bonded phases.<br />
Description qty. cat.#<br />
High-pressure filter ea. 25082<br />
10 mm guard cartridge holder without filter ea. 25083<br />
10 mm guard cartridge holder with filter ea. 25084<br />
PEEK tip for Waters-style end fittings ea. 25088<br />
PEEK tip for st<strong>and</strong>ard fittings ea. 25087<br />
Replacement Cap Frits : 4 mm 2.0 μm 5-pk. 25022<br />
Replacement Cap Frits : 4 mm 0.5 μm 5-pk. 25023<br />
Replacement Cap Frits : 2 mm 2.0 μm 5-pk. 25057<br />
Replacement Cap Frits : 2 mm 0.5 μm 5-pk. 25990<br />
*The st<strong>and</strong>ard PEEK tip in Trident direct systems is compatible with Parker,<br />
Upchurch Scientific, Valco, <strong>and</strong> other CPI-style fittings. To use Trident direct<br />
25084<br />
systems with Waters-style end fittings, replace the tip with cat.# 25088.<br />
innovative chromatography products<br />
3
NEW!<br />
Genuine Restek ® Replacement Parts<br />
for Waters ACQUITY UPLC ® Systems<br />
Keep your instrument running its best with these rock-solid,<br />
economical alternatives to high-cost vendor parts.<br />
25958<br />
26428<br />
25954<br />
Description Model #<br />
Similar to Waters<br />
part #<br />
qty. cat.#<br />
Needle Assembly, 0.010 mm ID ACQUITY 700002644 ea. 25942<br />
Sample Loop, 10 μL ACQUITY, nanoACQUITY 430001326 ea. 25943<br />
Wash Station O-Ring ACQUITY, nanoACQUITY 700002572 ea. 25944<br />
Metering Syringe, 100 μL ACQUITY, nanoACQUITY 700002570 ea. 25945<br />
Tube Assembly, Inject Outlet ACQUITY 430001084 ea. 25946<br />
Tube Assembly, System Outlet ACQUITY 430001486 ea. 25947<br />
Tube Assembly, SSV to In-line Filter nanoACQUITY 430001470 ea. 25948<br />
Tube Assembly, Transducer to Check Valve, BSM ACQUITY, nanoACQUITY 430001121 ea. 25949<br />
Tube Assembly, Transducer to Check Valve, QSM ACQUITY 430002357 ea. 25950<br />
Tube Assembly, SSV to I2V ACQUITY 430001443 ea. 25941<br />
Head Plunger Seal Kit ACQUITY, nanoACQUITY 700002599 kit 26428<br />
Wash Seal ACQUITY, nanoACQUITY 700002598 2-pk. 26429<br />
Pump O-Ring ACQUITY, nanoACQUITY WAT076152 ea. 25951<br />
Sapphire Plungers ACQUITY, nanoACQUITY 700002600 2-pk. 25958<br />
In-Line Filter Assembly, Stainless Steel Frit ACQUITY, nanoACQUITY 289003547 ea. 25952<br />
Filter Frit Cartridge, Stainless Steel ACQUITY 700002913 ea. 25953<br />
Solvent Bottle Filters ACQUITY 700003616 7-pk. 25954<br />
Primary Check Valve ACQUITY, nanoACQUITY 700002596 2-pk. 25955<br />
Accumulator Check Valve (Double Ball & Seat) ACQUITY, nanoACQUITY 700002968 2-pk. 25956<br />
I2 Check Valve Cartridge ACQUITY 700005165 ea. 25957<br />
25944<br />
25953<br />
25955<br />
NEW! High-Quality Lab<br />
Glassware at an Inviting Price<br />
• Kuderna-Danish Evaporator, Snyder<br />
Columns <strong>and</strong> Concentrator Tubes<br />
• Soxhlet Extraction Apparatus<br />
• Erlenmeyer <strong>and</strong> Class A Volumetric Flasks<br />
Buy today at www.restek.com/glassware<br />
• Auto-Zero <strong>and</strong> Squeeze-O-Matic Burets<br />
• Separatory Funnels<br />
• Repeating Pipettes<br />
• Impingers<br />
4<br />
the visit LC www.restek.com accessories you need for all are your at www.restek.com/LCacc<br />
chromatography needs
LC Accessories<br />
EXP ® Fittings<br />
coupler<br />
Reusable fittings for easy,<br />
yet reliable HPLC & UHPLC connections<br />
• H<strong>and</strong>-tight fitting style achieves effortless HPLC seals—no tools needed!<br />
• Both h<strong>and</strong>-tight <strong>and</strong> hex-head styles wrench-tighten for reliable UHPLC use.<br />
• Patented ferrule can be installed repeatedly without compromising high-pressure seal.<br />
• Hybrid design combines the durability of titanium with the sealing ability of PEEK.<br />
• Cutting-edge system provides ZDV (zero dead volume) connection<br />
to any 10-32 female port.<br />
• Compatible with 1 /16" PEEK <strong>and</strong> stainless steel tubing.<br />
www.restek.com/exp<br />
hex-head<br />
h<strong>and</strong>-tight<br />
Simplify Routine<br />
LC Maintenance With<br />
These Convenient Kits<br />
• Significant savings over instrument manufacturer prices.<br />
• High-quality components in every kit.<br />
• Wide range of options for HPLC systems <strong>and</strong> pumps.<br />
Save on<br />
Detector<br />
Lamps<br />
25145<br />
For a complete selection, visit<br />
www.restek.com/LC-Maintenance<br />
25259<br />
For a complete<br />
listing of lamps<br />
grouped by<br />
manufacturer, visit<br />
www.restek.com/LCLamps<br />
innovative chromatography products<br />
5
High Capacity TO-Clean Canister Cleaning<br />
System Improves Lab Efficiency<br />
One-year<br />
limited<br />
warranty!<br />
Dimensions:<br />
44"H x 48"W<br />
x 27"D<br />
Weight:<br />
525 lb<br />
Easily Create Custom Cleaning Programs: Create up to ten<br />
different methods using the on-board touch screen controller.<br />
Define the number of cycles, pressure, <strong>and</strong> soak times, then save<br />
the method for later use. Ensures consistent procedures are<br />
followed <strong>and</strong> makes operation as simple as pressing “start.”<br />
Ensure Performance with Easy, On-Board Diagnostics: With<br />
embedded diagnostic software, you can check for leaks <strong>and</strong> test<br />
valve operation at the touch of a button. Quick <strong>and</strong> easy system<br />
verification ensures effective cleaning.<br />
Oven Control at Your Fingertips: Isothermal oven cleans both<br />
canisters <strong>and</strong> valves faster <strong>and</strong> more completely than a heating<br />
b<strong>and</strong> system. Temperature is adjustable up to 110 °C.<br />
Cut Cleaning Time in Half: The high capacity interior holds twice as many canisters as similar models, which<br />
lets you finish cleaning faster. EPA Method TO-14A/15 compliant unit holds up to twelve 6-liter or twenty-four<br />
1-liter canisters.<br />
Air Canisters for VOC Monitoring<br />
SilcoCan® & TO-Can® Air Monitoring Canisters<br />
TO-Can® Canisters:<br />
• Proprietary electropolished surface maintains<br />
compound stability.<br />
• Ideal for TO-14A <strong>and</strong> TO-15, ASTM D5466, <strong>and</strong> other<br />
VOC methods.<br />
SilcoCan® Canisters:<br />
• Siltek® passivation offers unsurpassed inertness.<br />
• Especially suited for low-level reactive sulfur (1–20 ppb)<br />
<strong>and</strong> brominated compounds.<br />
6<br />
shop for air canisters, canister cleaners & more at www.restek.com/air
Air Sampling<br />
Meet 2 nd Source Gas St<strong>and</strong>ard<br />
Requirements With 1 Order<br />
Restek features a wide selection of high-quality air monitoring gas<br />
calibration st<strong>and</strong>ards. Each mix is independently manufactured for<br />
Restek by both Spectra/Linde <strong>and</strong> Scott/Air Liquide, enabling you to<br />
purchase your gas st<strong>and</strong>ards from 2 separate sources with the<br />
convenience of placing just 1 order!<br />
• Each mix is produced gravimetrically using NIST-traceable<br />
weights for improved accuracy.<br />
• Unique serial numbers <strong>and</strong> certificates of analysis give you<br />
confidence in cylinder contents <strong>and</strong> your final data.<br />
• All TO-14A <strong>and</strong> TO-15 gas st<strong>and</strong>ards feature at least<br />
12-month stability.<br />
• Recertification is available directly from the suppliers.<br />
• Disposable cylinders save rental <strong>and</strong> demurrage fees.<br />
• Drop-shipment by the manufacturer ensures fast<br />
delivery <strong>and</strong> maximum shelf life.<br />
For more details, ordering information, <strong>and</strong> full<br />
component lists, go to www.restek.com/2ndsource<br />
Cylinders available<br />
with or without<br />
Pi mark!<br />
Tedlar® Sample Bags Available!<br />
• Find the bags you need—we offer sizes from 0.5 liters to 100 liters.<br />
• Unique all-in-one septum <strong>and</strong> valve fitting make these lightweight<br />
<strong>and</strong> easy to use.<br />
• Polypropylene or stainless steel valve options.<br />
• Both valves conveniently connect to ³⁄16" ID PTFE tubing.<br />
Also Available<br />
PTFE Faced Silicone<br />
Replacement Septa<br />
(cat.# 22104) <strong>and</strong><br />
Multilayer<br />
Foil Bags<br />
Polypropylene Valve Stainless Steel Valve<br />
Description qty. cat.# cat.#<br />
0.5 L 6" x 6" 10-pk. 22049 22038<br />
1 L 7" x 7" 10-pk. 22050 22039<br />
3 L 9.5" x 10" 10-pk. 22051 22040<br />
5 L 12" x 12.5" 10-pk. 22052 22041<br />
10 L 11.75" x 22" 10-pk. 22053 22042<br />
12 L 13" x 24" 10-pk. 22054 22043<br />
25 L 17.5" x 24" 5-pk. 22055 22044<br />
40 L 24" x 24.25" 5-pk. 22056 22045<br />
80 L 28.25" x 30.5" 5-pk. 22057 22046<br />
100 L 28" x 36" 3-pk. 22058 22047<br />
innovative chromatography products<br />
7
NEW GC Columns for PAH Analysis<br />
Rxi®-PAH Columns Resolve Important Isobaric Polycyclic Aromatic<br />
Hydrocarbons for Food Safety & Environmental Methods<br />
• Separation of all EFSA PAH4 compounds: benz[a]anthracene, chrysene,<br />
benzo[b]fluoranthene, <strong>and</strong> benzo[a]pyrene.<br />
• Best resolution of chrysene from interfering PAHs, triphenylene<br />
<strong>and</strong> cyclopenta[cd]pyrene.<br />
• Complete separation of benzo [b], [k], [j], <strong>and</strong> [a] fluoranthenes.<br />
• 360 °C thermal stability allows analysis of low volatility dibenzo pyrenes.<br />
Whether you want more resolution or faster analysis times, new Rxi®-PAH columns have<br />
the selectivity <strong>and</strong> efficiency you need. Choose the configuration that is best for your separation.<br />
Cat.# Length ID df Description<br />
49316 40 m 0.18 mm 0.07 μm Narrow inside diameter, thinner film, faster analysis, excellent separation of important PAHs,<br />
less sample loading capacity<br />
49317 60 m 0.25 mm 0.10 μm 0.25 mm inner diameter, better sample loading capacity, highest resolution of important PAHs,<br />
longer analysis than 0.18 mm column, thin film allows elution of dibenzo pyrenes<br />
49318 30 m 0.25 mm 0.10 μm 0.25 mm inside diameter, better sample loading capacity, faster analysis time<br />
than 60 m column, adequate resolution of important PAHs, lower cost column<br />
Order<br />
yours today at<br />
www.restek.com/<br />
rxi-pah<br />
A 40 m x 0.18 mm x 0.07 μm Rxi®-PAH column produces excellent resolution of critical peaks in less than 33 minutes!<br />
1<br />
2<br />
3<br />
4<br />
5<br />
7<br />
6<br />
8<br />
benz[a]anthracene<br />
triphenylene chrysene<br />
17<br />
13 14 16<br />
9<br />
12<br />
15.20 15.80 16.40 17.00 17.60<br />
10 11<br />
15<br />
12<br />
13<br />
Separate <strong>and</strong> accurately<br />
quantify EFSA PAH4<br />
priority compounds.<br />
22.40 22.80 23.20 23.60<br />
14<br />
15<br />
17<br />
16<br />
18<br />
benzo [b], [k], [j], & [a]<br />
fluoranthenes<br />
20<br />
19<br />
GC_FF1223<br />
21 21<br />
18<br />
20<br />
19<br />
21<br />
benzo[a]<br />
pyrene<br />
22 23 24<br />
26.40 26.80 27.20 27.60 28.00 28.40<br />
80<br />
31<br />
26,27,28<br />
25<br />
25<br />
27 27<br />
26<br />
29 30<br />
28<br />
31 31<br />
29 30 32 33<br />
4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 30.00 32.00<br />
Tim<br />
Complete analytical conditions are available at www.restek.com by searching for GC_FF1223<br />
Time (min)<br />
3435<br />
32 32<br />
36<br />
Peaks<br />
1. Naphthalene<br />
2. Biphenyl<br />
3. Acenaphthylene<br />
4. Acenaphthene<br />
5. Fluorene<br />
6. Dibenzothiophene<br />
7. Phenanthrene<br />
8. Anthracene<br />
9. 4H-Cyclopenta[def]<br />
phenanthrene<br />
10. Fluoranthene<br />
11. Pyrene<br />
12. Benzo[ghi]fluoranthene<br />
13. Benzo[c]phenanthrene<br />
14. Benz[a]anthracene<br />
15. Cyclopenta[cd]pyrene<br />
16. Triphenylene<br />
17. Chrysene<br />
18. Benzo[b]fluoranthene<br />
19. Benzo[k]fluoranthene<br />
20. Benzo[ j]fluoranthene<br />
21. Benzo[a]fluoranthene<br />
22. Benzo[e]pyrene<br />
23. Benzo[a]pyrene<br />
24. Perylene<br />
25. Dibenz[a,j]anthracene<br />
26. Dibenz[a,c]anthracene<br />
27. Indeno[1,2,3-cd]pyrene<br />
28. Dibenz[a,h]anthracene<br />
29. Benzo[b]chrysene<br />
30. Picene<br />
31. Benzo[ghi]perylene<br />
32. Anthanthrene<br />
33. Dibenzo[b,k]<br />
fluoranthene<br />
34. Dibenzo[a,e]pyrene<br />
35. Coronene<br />
36. Dibenzo[a,h]pyrene<br />
8 visit www.restek.com for all your chromatography needs
Restek® Guards Capture Harmful<br />
Contaminants Before They Reach<br />
Your Analytical GC Column<br />
GC Columns<br />
• Capture non-volatile sample residue that can cause bleed, tailing peaks, loss of response, <strong>and</strong><br />
other performance issues if it reaches your analytical column.<br />
• Extend analytical column life <strong>and</strong> reduce downtime by helping eliminate the need for<br />
column trimming.<br />
• Batch tested to ensure high inertness; chromatogram included.<br />
• Available in fused silica or metal MXT® tubing.<br />
• Match your Restek® guard column to your application <strong>and</strong> analytical column for optimum<br />
performance.<br />
Guard<br />
Column<br />
Maximum<br />
Temperature<br />
Tubing<br />
Availability<br />
Recommended<br />
Applications<br />
Recommended<br />
Analytical Columns<br />
Rxi® 360 °C Fused Silica Active compounds Rxi®<br />
Intermediate-Polarity<br />
Deactivated<br />
Hydroguard®<br />
Water-Resistant<br />
325 °C<br />
325 °C<br />
Fused Silica &<br />
Metal MXT®<br />
Fused Silica &<br />
Metal MXT®<br />
Wide range of<br />
compounds & solvents<br />
Samples in<br />
water-based matrix<br />
Base-Deactivated 315 °C Fused Silica Basic compounds<br />
Polar-Deactivated 280 °C Fused Silica<br />
Polar compounds<br />
& solvents<br />
Rtx® & MXT®<br />
Rxi®, Rtx® & MXT®<br />
Rtx®-5 Amine,<br />
Rtx®-35 Amine,<br />
Rtx® Volatile Amine<br />
& Stabilwax® DB<br />
Stabilwax®,<br />
Stabilwax® DA<br />
& Rtx®-Wax<br />
Visit www.restek.com/GCguards for a<br />
complete listing of dimensions <strong>and</strong> specifications<br />
innovative chromatography products 9
7 Pesticide Methods on 1 Column Pair!<br />
Analyze Pesticides, PCBs, Herbicides, <strong>and</strong> More on a Single Column Set<br />
Get improved resolution, faster analyses, <strong>and</strong> less downtime with an Rtx®-CLPesticides <strong>and</strong><br />
Rtx®-CLPesticides2 column set for multiple GC-ECD methods. Instead of changing columns between<br />
methods*, you can save time by using the same column set to analyze:<br />
Chlorinated pesticides • PCBs • Herbicides • Haloacetic acids • Other halogenated compounds<br />
Rtx®-CLPesticides columns feature very low bleed for the<br />
highest sensitivity <strong>and</strong> offer faster analysis time with full<br />
separation of chlorinated pesticides.<br />
Organochlorine Pesticide Mix AB #2<br />
on Rtx®-CLPesticides <strong>and</strong><br />
Rtx®-CLPesticides2<br />
(0.32 mm ID column set)<br />
Rtx®-CLPesticides<br />
Buy a Column Kit & Save!<br />
Rtx®-CLPesticides Column Kit (0.25 mm ID)<br />
Rtx-CLPesticides Kit (0.25 mm ID) cat.# 11199 (kit)<br />
SAVE<br />
with our Rtx®-<br />
CLPesticides<br />
Kits<br />
Analytical columns, guard columns, <strong>and</strong> connectors<br />
are available separately, but you can save big just by<br />
ordering one of our recommended combinations packed<br />
in a convenient, pre-built kit!<br />
Includes:<br />
cat.#<br />
30 m, 0.25 mm ID, 0.25 μm Rtx-CLPesticides Column Column 11123<br />
30 m, 0.25 mm ID, 0.20 μm Rtx-CLPesticides2 Column Column 11323<br />
Universal Angled “Y” Press-Tight Connector , Deactivated 20403-261<br />
5 m, 0.25 mm ID Siltek Guard Column 10026<br />
0.32 mm ID column analysis<br />
performed in less than 7 minutes!<br />
Rtx®-CLPesticides2<br />
GC_EV00933<br />
Rtx®-CLPesticides Column Kit (0.32 mm ID)<br />
Rtx-CLPesticides Kit (0.32 mm ID) cat.# 11196 (kit)<br />
Includes:<br />
cat.#<br />
30 m, 0.32 mm ID, 0.32 μm Rtx-CLPesticides Column Column 11141<br />
30 m, 0.32 mm ID, 0.25 μm Rtx-CLPesticides2 Column Column 11324<br />
Universal Angled “Y” Press-Tight Connector , Deactivated 20403-261<br />
5 m, 0.32 mm ID Siltek Guard Column 10027<br />
Rtx®-CLPesticides Column Kit (0.53 mm ID)<br />
Rtx-CLPesticides Kit (0.53 mm ID) cat.# 11197 (kit)<br />
Includes:<br />
cat.#<br />
30 m, 0.53 mm ID, 0.50 μm Rtx-CLPesticides Column Column 11140<br />
30 m, 0.53 mm ID, 0.42 μm Rtx-CLPesticides2 Column Column 11340<br />
Universal Angled “Y” Press-Tight Connector , Deactivated 20403-261<br />
5 m, 0.53 mm ID IP Deactivated Guard Column 10045<br />
GC_EV00933A<br />
Complete analytical conditions are available at www.restek.com by searching for GC_EV00933<br />
(Note: Columns are not preconnected in this kit.)<br />
* NOTE: If analyzing trace-level pesticide samples following dirty or derivatized samples,<br />
Restek recommends first performing st<strong>and</strong>ard inlet maintenance, such as trimming the guard<br />
column <strong>and</strong> changing the inlet liner, seal, <strong>and</strong> septum.<br />
10<br />
learn more at www.restek.com/RtxCLP7
GC Columns<br />
Separate Permanent Gases With Restek ®<br />
Molecular Sieve 5A PLOT Columns<br />
Our revolutionary molecular sieve<br />
5A PLOT columns are designed for<br />
efficient separation of Ar/O2 <strong>and</strong> H2/He<br />
at or above ambient temperature (see<br />
chromatogram) as well as CH4, C2H6, <strong>and</strong><br />
CO. These columns also are an excellent<br />
choice for rapid separation of gases in<br />
refinery or natural gas.<br />
Rt®-Msieve 5A Columns (fused silica PLOT)<br />
ID df temp. limits 15-Meter 30-Meter<br />
0.25 mm 20 μm to 300 °C 19773<br />
0.32 mm 30 μm to 300 °C 19720 19722<br />
0.53 mm 50 μm to 300 °C 19721 19723<br />
Separation of Argon/Oxygen <strong>and</strong><br />
Other Permanent Gases on Rt®-Msieve 5A<br />
Conc.<br />
Peaks (μg/mL)<br />
1. Hydrogen 40<br />
2. Argon 30<br />
3. Oxygen 50<br />
4. Nitrogen 50<br />
5. Methane 40<br />
6. Carbon<br />
monoxide 50<br />
Argon<br />
resolved<br />
from<br />
oxygen.<br />
2<br />
3 4<br />
Excellent peak shape<br />
for carbon monoxide.<br />
0 2 4 6 8 10 Time(min)<br />
For larger view <strong>and</strong> conditions, visit www.restek.com <strong>and</strong> enter<br />
chromatogram GC_PC00898 in the search function.<br />
5<br />
GC_PC00898<br />
6<br />
MXT®-Msieve 5A Columns (metal MXT PLOT)<br />
3.5" coil<br />
7" diameter<br />
11-pin cage<br />
3.5" coil<br />
7" diameter<br />
11-pin cage<br />
ID df (μm) temp. limits 15-Meter 15-Meter 30-Meter 30-Meter<br />
0.25 mm 20 μm to 300 °C 79717-273 79717<br />
0.53 mm 50 μm to 300 °C 79723-273 79723<br />
Choose<br />
fused silica or<br />
metal MXT®<br />
tubing!<br />
Restek ® Porous Polymer PLOT Columns —<br />
The New Benchmark For Performance!<br />
• Stabilized particle layers improve robustness <strong>and</strong><br />
reproducibility of retention <strong>and</strong> flow.<br />
• Fully compatible with valve switching <strong>and</strong> Deans<br />
switching systems.<br />
• Highly efficient, reproducible analyses; ideal for<br />
permanent gases, solvents, <strong>and</strong> hydrocarbons.<br />
• Innovative manufacturing procedure reduces particle<br />
generation <strong>and</strong> improves performance.<br />
Available In:<br />
Fused Silica Rt® Column Solid Phases:<br />
Rt®-Q-BOND Rt®-S-BOND<br />
Rt®-QS-BOND Rt®-U-BOND<br />
Metal MXT® Column Solid Phases:<br />
MXT®-Q-BOND MXT®-S-BOND<br />
Restek® porous polymer<br />
PLOT columns cover a<br />
wide range of polarities<br />
Q-BOND<br />
QS-BOND<br />
S-BOND<br />
U-BOND<br />
Least<br />
Polar<br />
Most<br />
Polar<br />
Order your PLOT columns today at www.restek.com/PLOT<br />
innovative chromatography products<br />
11
Upgrade the FID Jets in your Agilent GCs<br />
Which FID Jet Should I Use?<br />
There are two FID jet<br />
configurations for Agilent GCs.<br />
The longer “adaptable” jet fits<br />
both 5890 <strong>and</strong> 6890 GCs, <strong>and</strong> can be<br />
used with capillary or packed columns.<br />
The shorter “dedicated” jet is for the FID<br />
in the 6890/7890 GC that is designed<br />
only for use with capillary columns.<br />
tech<br />
tip<br />
St<strong>and</strong>ard Version<br />
• Threads specially coated for easy installation <strong>and</strong> removal.<br />
• Special processing ensures the highest degree of cleanliness.<br />
• Meets or exceeds original manufacturer's performance.<br />
High-Performance Version—Siltek® Treated<br />
• Similar to the st<strong>and</strong>ard version, but Siltek® treated.<br />
• Extremely inert, for use with active compounds.<br />
Capillary Adaptable FID Replacement Jet for Agilent 5890/6890/6850 GCs<br />
Engineered with a fluted tip to guide the capillary column into the jet.<br />
Description<br />
Similar to<br />
Agilent part # qty. cat.# qty. cat.#<br />
St<strong>and</strong>ard, 0.011-Inch ID Tip 19244-80560 ea. 20670 3-pk.20671<br />
High-Performance Siltek Treated,<br />
0.011-Inch ID Tip<br />
19244-80560 ea.20672 3-pk.20673<br />
Capillary Dedicated FID Replacement Jet for Agilent 6890/6850/7890 GCs<br />
Description<br />
Similar to<br />
Agilent part # qty. cat.# qty. cat.#<br />
St<strong>and</strong>ard, 0.011-Inch ID Tip G1531-80560 ea. 21621 3-pk.21682<br />
High-Performance Siltek Treated,<br />
0.011-Inch ID Tip<br />
G1531-80560 ea.21620 3-pk.21683<br />
High-Temperature, 0.018-Inch ID Tip G1531-80620 ea. 23078 3-pk.23079<br />
Easily Remove <strong>and</strong> Install FID Jets<br />
With Our FID Jet Removal Tool<br />
FID Jet Removal Tool for Agilent 5890/6890/6850/7890 FIDs<br />
• Securely grips jet in socket for easy removal or installation.<br />
• Unique, ergonomic h<strong>and</strong>le—easy to hold.<br />
Slip tool over FID jet... ...loosen jet... ...<strong>and</strong> remove.<br />
Description qty. cat.#<br />
FID Jet Removal Tool for Agilent 5890/6890/6850/7890 FIDs ea. 22328<br />
FID flow measuring adaptor also available! Search for cat.# 21000 at www.restek.com<br />
12<br />
visit www.restek.com for all your chromatography needs
GC Accessories<br />
Switch to Precision-Molded,<br />
Low-Bleed Septa From Restek<br />
• Precision molding assures<br />
consistent, accurate fit.<br />
• Preconditioned <strong>and</strong> ready to use.<br />
• Packaged in ultra-clean blister packs**.<br />
Restek® Thermolite® Septa<br />
• Usable to 340 °C inlet<br />
temperature*.<br />
• Excellent puncturability.<br />
• A Restek exclusive!<br />
Septum Diameter 50-pk. 100-pk.<br />
5 mm ( 3 /16") 27121 27122<br />
6 mm ( 1 /4") 27124 27125<br />
7 mm 27127 27128<br />
8 mm 27130 27131<br />
9 mm 27133 27134<br />
9.5 mm ( 3 /8") 27136 27137<br />
10 mm 27139 27140<br />
11 mm ( 7 /16") 27142 27143<br />
11.5 mm 27145 27146<br />
12.7 mm ( 1 /2") 27148 27149<br />
17 mm 27151 27152<br />
Shimadzu <strong>Plug</strong> 27154 27155<br />
Premium Non-Stick BTO® Septa<br />
• Usable to 400 °C inlet temperature*.<br />
• New plasma coating eliminates sticking in the injection port.<br />
• Partial predrilled CenterGuide design.<br />
• Each batch GC-FID tested.<br />
• Bleed <strong>and</strong> temperature optimized; ideal<br />
for dem<strong>and</strong>ing GC <strong>and</strong> GC-MS applications.<br />
NEW!<br />
Septum Diameter 50-pk. 100-pk.<br />
5 mm CenterGuide 27082 27083<br />
9 mm CenterGuide 27084 27085<br />
9.5 mm ( 3 /8") 27086 27087<br />
10 mm 27088 27089<br />
11 mm ( 7 /16") CenterGuide 27090 27091<br />
11.5 mm CenterGuide 27092 27093<br />
12.7 mm ( 1 /2") CenterGuide 27094 27095<br />
17 mm CenterGuide 27096 27097<br />
Shimadzu <strong>Plug</strong> 27098 27099<br />
Note: Due to differences in inlet design, the actual septum temperature for a given inlet setpoint can vary by manufacturer. Restek recommends using only BTO® septa in Thermo TRACE <strong>and</strong><br />
Focus GCs. *For 17 mm inlets, the maximum temperature is 330 °C. For all injectors, minimum recommended operating temperature for BTO® septa is 250 °C. **12.7 mm <strong>and</strong> 17 mm septa<br />
packaged in precleaned glass jars.<br />
Measure<br />
your old<br />
septum here<br />
(size in mm)<br />
5 7 9 9.5 10 11 11.5 12.7 17<br />
View our full selection at<br />
www.restek.com/septa<br />
Never Use a Washer Again!<br />
Our patented dual Vespel® ring inlet seal greatly improves injection port performance—<br />
it stays sealed, even after repeated temperature cycles, without retightening the<br />
reducing nut! This seal features two soft Vespel® rings that eliminate the<br />
need for a washer <strong>and</strong> need very little torque to make a leak-tight seal.<br />
0.8 mm ID Dual Vespel Ring Inlet Seal 2-pk. 10-pk. 50-pk.<br />
Gold-Plated 21240 21241 23418<br />
Siltek-Treated 21242 21243 23419<br />
Stainless Steel 21238 21239 23420<br />
1.2 mm ID Dual Vespel Ring Inlet Seal 2-pk. 10-pk.<br />
Gold-Plated 21246 21247<br />
Siltek-Treated 21248 21249<br />
Stainless Steel 21244 21245<br />
Learn more at www.restek.com/dvr<br />
Save<br />
by ordering<br />
50-packs!<br />
restek<br />
innovation!<br />
innovative chromatography products<br />
13
Get Your GC-MS Essentials Here!<br />
GC-MS<br />
Interface<br />
Transfer<br />
Line<br />
EZ<br />
No-Vent®<br />
Connector<br />
Capillary<br />
Ferrule<br />
Capillary<br />
Nut<br />
Transfer<br />
Line<br />
Ferrule<br />
Capillary<br />
Column<br />
EZ No-Vent®<br />
GC Column-Mass<br />
Spectrometer Connector<br />
for Agilent GCs with 5971/5972, 5973,<br />
or 5975 GC-MS<br />
• Change GC-MS columns in minutes<br />
without venting—100 μm transfer<br />
line maintains vacuum <strong>and</strong><br />
eliminates the need to vent.<br />
• Easy to install <strong>and</strong> maintain—no<br />
special tools or plumbing required.<br />
• Gold-plated body for inertness.<br />
• High-temperature polyimide<br />
ferrules eliminate leaks at the<br />
problematic transfer line fitting.<br />
• Lower cost than other “no-vent”<br />
fittings.<br />
Description qty. cat.#<br />
EZ No-Vent Connector Kit<br />
includes: EZ No-Vent Connector, two 0.4 mm ID adaptor ferrules for<br />
capillary column, two 0.4 mm ID ferrules for transfer line, 100 μm<br />
kit 21323<br />
deactivated transfer line (3 ft.), column plug, column nut<br />
Replacement ferrules for connecting capillary column to EZ<br />
No-Vent Connector:<br />
0.4 mm (Polyimide)2-pk. 21015<br />
0.5 mm (Polyimide)2-pk. 21016<br />
Replacement Ferrules (polyimide) for connecting transfer line to<br />
EZ No-Vent connector: 0.4 mm ID<br />
2-pk. 21043<br />
Replacement 100 μm Deactivated Transfer Line 3 ft 21018<br />
Replacement EZ No-Vent Column Nut 20-pk. 23100<br />
Replacement EZ No-Vent <strong>Plug</strong> 5-pk. 23112<br />
Open-End Wrenches , 1<br />
/4" x 5 /16" 2-pk. 20110<br />
For other instrument-specific EZ No-Vent®<br />
connectors, visit www.restek.com<br />
Inl<strong>and</strong> 45 Pump Oil<br />
Recommended for most mass spectrometers.<br />
• Ease at cold start.<br />
• Low vapor pressure 10-7 torr.<br />
• Nontoxic <strong>and</strong> noncorrosive.<br />
• Compatible with buna-N, neoprene,<br />
<strong>and</strong> Viton® seals.<br />
• Optimum vacuum pump performance.<br />
• Lowest mass spectrometer background.<br />
• Recommended for optimum mass spec performance.<br />
Similar to<br />
Description<br />
Agilent part # qty. cat.#<br />
Inl<strong>and</strong> 45 Pump Oil 6040-0834 1 liter 24819<br />
ETP Electron Multipliers<br />
for Mass Spectrometry<br />
• Air stable.<br />
• 2-year shelf life guarantee.<br />
• Discrete dynode design extends operating life.<br />
Description qty. cat.#<br />
Electron Multipliers for Agilent GC-MS <strong>and</strong> LC-MS<br />
For Agilent 5970 GC-MS ea. 23072<br />
For Agilent 5971, 5972, GC GC-MS ea. 23073<br />
For Agilent 5973 & 5975 GC-MS (includes mount for initial installation)*†<br />
ea. 23074<br />
For Agilent 5973 & 5975 GC-MS <strong>and</strong> LC-MSD (Replacement Multiplier)*†<br />
ea. 23075<br />
Other ETP Electron Multipliers are available upon request. Call us or contact your Restek®<br />
representative if you do not see your instrument listed.<br />
MSD Source Nut<br />
• 1.2 mm nut bore permits easy removal of ferrules with a<br />
st<strong>and</strong>ard tapered-needle file (cat.# 20106).<br />
• Made of brass to prevent threadstripping<br />
on the transfer line.<br />
• Design enhances ease of threading<br />
onto the transfer line <strong>and</strong> improves overall lifetime.<br />
Similar to<br />
Description<br />
Agilent part # qty. cat.#<br />
(Detector) MSD Source Nut 05988-20066 2-pk. 20643<br />
GC-MS Cleaning Kit<br />
Poor sensitivity, loss of<br />
sensitivity at high masses,<br />
or high multiplier gain<br />
during an auto tune are<br />
all indicators that your<br />
mass spectrometer source may need to be cleaned. Restek<br />
has assembled all of the necessary components for cleaning<br />
<strong>and</strong> polishing your ion source.<br />
Ion Source Cleaning Powder<br />
27194<br />
Description qty. cat.#<br />
Mass Spec Cleaning Kit with Dremel Tool kit 27194<br />
Mass Spec Cleaning Kit without Dremel Tool kit 27195<br />
Mass Spec Cleaning Kit Replacement Parts Kit<br />
Includes: cloths, micro mesh sheets, small <strong>and</strong> large gloves<br />
kit 27196<br />
Use this aluminum oxide powder to clean<br />
surfaces that contact the sample or ion beam<br />
when you encounter poor sensitivity <strong>and</strong><br />
inadequate abundances at high masses.<br />
Similar to<br />
Description<br />
Agilent part # qty. cat.#<br />
Ion Source Cleaning Powder 8660-0791 1 kg 22685<br />
14<br />
visit www.restek.com/gcacc for a full listing of GC accessories
GC Accessories<br />
Choose Screw-Thread Headspace Vials<br />
for Your Gerstel or CTC/LEAP Samplers<br />
• Compatible with Gerstel <strong>and</strong> CTC/LEAP Technologies headspace<br />
samplers when used with magnetic closures.<br />
Headspace Screw-Thread Vials (18 mm)<br />
Description Volume Color Dimensions 100-pk. 1000-pk.<br />
Headspace Vial 10 mL Clear 22 x 45 mm 23084 23085<br />
Headspace Vial 10 mL Amber 22 x 45 mm 23088 23089<br />
Headspace Vial 20 mL Clear 22 x 75 mm 23082 23083<br />
Headspace Vial 20 mL Amber 22 x 75 mm 23086 23087<br />
Caps not included (sold separately).<br />
18 mm Magnetic Screw-Thread Caps<br />
Description Septa Material 100-pk. 1000-pk.<br />
Magnetic Caps <strong>and</strong> Septa PTFE/Silicone 23090 23091<br />
Magnetic Caps <strong>and</strong> Septa PTFE/Silicone for SPME 23092 23093<br />
Magnetic Caps <strong>and</strong> Septa PTFE/Red Chlorobutyl 23094 23095<br />
Get The Security of a Crimp-Top Vial<br />
With the <strong>Convenience</strong> of a Screw-Thread<br />
• Shorter screw cap allows the robotic autosampler to function properly.<br />
• Wider opening prevents syringe problems.<br />
• Dimensions are effectively identical to the crimp-top vial.<br />
2.0 mL, 9 mm Short-Cap, Screw-Thread Vials (vial only)<br />
Description Volume Color 100-pk. 1000-pk.<br />
Short-Cap Vial w/White Graduated Marking Spot 2.0 mL Clear 21140 21141<br />
Short-Cap Vial w/White Graduated Marking Spot 2.0 mL Amber 21142 21143<br />
Short-Cap Vial without Graduated Marking Spot 2.0 mL Clear 21154 21155<br />
2.0 mL, 9 mm Short-Cap, Screw-Vial Closures (Polypropylene, preassembled)<br />
Cap Color Liner Material 100-pk. 500-pk. 1,000-pk.<br />
Blue PTFE/Butyl Rubber 24473 — 24474<br />
Mixed PTFE/Butyl Rubber —24668 —<br />
Blue PTFE/Silicone 24485 —24486<br />
Green PTFE/Silicone 24487 —24488<br />
Yellow PTFE/Silicone 24493 — 24494<br />
Mixed PTFE/Silicone —24669 —<br />
Blue PTFE/Silicone/PTFE 24497 — 24498<br />
Black PTFE/Silicone/PTFE 24495 — 24496<br />
Natural PTFE/Silicone/PTFE 24501 —24502<br />
Red PTFE/Silicone/PTFE 24503 —24504<br />
Yellow PTFE/Silicone/PTFE 24505 —24506<br />
Mixed PTFE/Silicone/PTFE —24670 —<br />
23082 23084 23086 23088<br />
23090 23094<br />
21140<br />
Agilent Compatible!<br />
Ideal for Agilent 7673, 7683, 7693 & other autosamplers<br />
that process 12 x 32 mm crimp-top vials.<br />
24668<br />
Don’t Forget the Rack! 2.0 mL Sample Vial Racks<br />
• Racks feature alphanumeric indexing for easier vial identification.<br />
• Racks can be stacked for efficient storage.<br />
Description Capacity qty. cat.# qty. cat.#<br />
Polypropylene Storage Rack for 12 x 32 mm Vials 50 vials, 5 x 10 ea. 22856 5-pk. 22857<br />
Crimp-Top Vials Also Available<br />
innovative chromatography products 15
GC Columns<br />
Solid Phase Extraction Cartridges from Restek<br />
Proven Quality • Superior Cleanliness • Method-Specific Performance<br />
Available with the following sorbents:<br />
• Silica: Multipurpose<br />
• EPH Silica: Petroleum<br />
• Florisil® Adsorbent: Pesticides<br />
• CarboPrep® Adsorbent: Dirty Samples<br />
FREE samples available!<br />
Contact us or your local Restek® representative.<br />
Learn more at www.restek.com/resprep<br />
Perfect<br />
for pesticide<br />
analysis! Pair with<br />
Rtx®-CLPesticides Columns (page 10).<br />
Go Green!<br />
Help Save the Environment <strong>and</strong> Save Time in<br />
the Lab With Q-sep QuEChERS Products<br />
REDUCE:<br />
Easy-pour packets create far less waste<br />
than tubes of extraction salts.<br />
REUSE:<br />
Highly inert FEP centrifuge tubes are<br />
reusable indefinitely under normal use.<br />
RECYCLE:<br />
Packet boxes consist of at least 33% recycled<br />
cardboard <strong>and</strong> are 100% recyclable.<br />
Available for European EN 15662,<br />
AOAC 2007.01, <strong>and</strong> Original Unbuffered Methods.<br />
Visit www.restek.com/quechers for full product lists<br />
16 visit www.restek.com for all your chromatography needs
Sample Preparation<br />
Replacement Parts & Accessories<br />
for ASE ® Systems<br />
Including Models 100,<br />
150, 200, 300, <strong>and</strong> 350<br />
• Extraction Cell Parts<br />
• PEEK Washers<br />
• Collection Vials<br />
• O-Rings<br />
• Filters<br />
• Tools<br />
• And More!<br />
Order now at<br />
www.restek.com/ase<br />
Syringe Filters with Luer Lok Inlet<br />
• Luer lok inlet offers leak-tight syringe connection.<br />
• Variety of filter types, porosities, <strong>and</strong> diameters.<br />
• Color coded for easy identification.<br />
• Rugged polypropylene housing.<br />
• Autoclavable to 121 °C for 15 minutes.<br />
• Quantity break pricing for greater savings.<br />
View our exp<strong>and</strong>ed line at<br />
www.restek.com/filters<br />
innovative chromatography products<br />
17
Reference St<strong>and</strong>ards<br />
Detect <strong>and</strong> Quantify<br />
204 Pesticides of<br />
Global Concern by<br />
LC-MS/MS<br />
• Full kit of reference st<strong>and</strong>ards contains 204 compounds of interest, covering many<br />
LC-determined pesticides listed by government agencies; individual ampuls also sold separately.<br />
• Formulated <strong>and</strong> grouped for maximum shelf life <strong>and</strong> well-balanced chromatographic<br />
performance, even for early eluting compounds.<br />
• Quantitatively tested to confirm composition <strong>and</strong> long-term stability; detailed support<br />
documentation provided.<br />
• Optimized multi-residue pesticide method is offered free of charge; downloadable XLS file<br />
includes conditions <strong>and</strong> transition tables.<br />
• Ideal for a wide range of fruits, vegetables, <strong>and</strong> other commodities.<br />
• Restek is your complete supplier for world-class LC-MS/MS multi-residue pesticide analysis:<br />
reference <strong>and</strong> internal st<strong>and</strong>ards, Ultra <strong>and</strong> Pinnacle® DB LC columns, Q-sep QuEChERS sample<br />
prep products, accessories, <strong>and</strong> more!<br />
Learn more at www.restek.com/LC-multi-residue<br />
QUALITY<br />
9001 17025 Guide 34<br />
Accurately Determine Mineral Oil<br />
Hydrocarbons in Food Using Our<br />
New MOSH/MOAH St<strong>and</strong>ard<br />
• Developed specifically for using LC coupled with GC-FID to accurately determine<br />
hydrocarbons found in mineral oils, which can migrate from packaging into food.<br />
• 9-component mix contains non-interfering internal st<strong>and</strong>ards as well as both mineral oil<br />
saturated hydrocarbon (MOSH) <strong>and</strong> mineral oil aromatic hydrocarbon (MOAH) markers<br />
to correctly cut fractions.<br />
• Certified reference material (CRM) manufactured <strong>and</strong> QC-tested in Restek’s<br />
ISO-accredited labs satisfies your ISO requirements.<br />
• Restek is your complete supplier for world-class MOSH/MOAH analysis: reference<br />
st<strong>and</strong>ards, Allure® silica LC columns, Rxi®-5Sil MS GC columns, accessories, <strong>and</strong> more!<br />
Learn more at www.restek.com/mosh-moah<br />
LITY<br />
QUALITY<br />
U<br />
QUA<br />
T<br />
9001 17025 Guide 34<br />
18 visit ii www.restek.com for all your chromatography needs
Sample LC Preparation Columns<br />
Trident Direct Guard<br />
Column System<br />
Easy to Use, Low Dead Volume—The Ultimate<br />
Combination of <strong>Convenience</strong> <strong>and</strong> Column Protection<br />
XF<br />
fitting<br />
Trident Direct 10 mm guard<br />
cartridge holder with filter<br />
Cap<br />
Frit<br />
XG-XF<br />
Fitting<br />
Components<br />
Guard<br />
Cartridge<br />
Assembled<br />
PEEK<br />
Tip<br />
Installed onto column<br />
XG<br />
Fitting<br />
Unlike “one size fits all” column guards,<br />
the Trident Direct system gives you<br />
the power to select the right level of<br />
protection for your analysis. Choose<br />
from 3 levels of protection, guard<br />
cartridges in 4 dimensions, <strong>and</strong> a variety<br />
of bonded phases. A Trident Direct with<br />
its economical, leak-free cartridge design<br />
provides an unprecedented combination<br />
of convenience, economy, <strong>and</strong> reliability!<br />
Removable<br />
cap frits<br />
Double the<br />
Protection:<br />
Replacement guard<br />
cartridges can cost as much<br />
as an analytical column, so<br />
why not protect them, too?<br />
The removable cap frit in a Trident Direct helps<br />
prevent clogged cartridges to extend the life of<br />
your column, your cartridge, <strong>and</strong> your budget!<br />
Trident Direct provides 3 levels of protection<br />
25082<br />
High-pressure filter<br />
Protection against particulate matter.<br />
25083<br />
10 mm guard cartridge holder<br />
Protection against particulate matter <strong>and</strong><br />
irreversibly adsorbed compounds.<br />
25084<br />
10 mm guard cartridge holder with filter<br />
Double protection against particulate matter<br />
<strong>and</strong> irreversibly adsorbed compounds.<br />
Order yours at www.restek.com/tridentdirect<br />
innovative chromatography products 19
Dynamic Duo<br />
Restek’s Leak Detector <strong>and</strong><br />
ProFLOW 6000 Flowmeter<br />
An<br />
Unbeatable<br />
Combination!<br />
Protect your instrument <strong>and</strong> improve data quality<br />
with this powerful pair from Restek. Checking for leaks <strong>and</strong><br />
verifying flows before you start helps you avoid costly problems later.<br />
Description qty. cat.#<br />
Dynamic Duo Combo Pack (Restek Leak Detector <strong>and</strong> ProFLOW 6000 Flowmeter) kit 22654<br />
Related Products <strong>and</strong> Accessories<br />
Leak Detector With Hard-Sided Carrying Case <strong>and</strong> Universal Charger Set<br />
(U.S., UK, European, Australian)<br />
ea. 22655<br />
Small Probe Adaptor for Leak Detector ea. 22658<br />
Restek ProFLOW 6000 Electronic Flowmeter With Hard-Sided Carrying Case ea. 22656<br />
Soft-Sided Storage Case for Leak Detector or ProFLOW 6000 Flowmeter ea. 22657<br />
PATENTS & TRADEMARKS<br />
Restek® patents <strong>and</strong> trademarks are the property of Restek Corporation. (See www.restek.com/Patents-Trademarks for full list.) Other trademarks appearing in Restek® literature or on its website are<br />
the property of their respective owners. The Restek® registered trademarks used here are registered in the United States <strong>and</strong> may also be registered in other countries.<br />
Lit. Cat.# GNES1847-INT<br />
2013.2<br />
© 2013 Restek Corporation. All rights reserved. Printed in the U.S.A.<br />
U.S. • 110 Benner Circle • Bellefonte, PA 16823 • 1-814-353-1300 • 1-800-356-1688 • fax: 1-814-353-1309 • www.restek.com<br />
China • phone: +86-10-5629-6620 • fax: +86-10-5814-3980 • cn.restek.com<br />
France • phone: +33 (0)1 60 78 32 10 • fax: +33 (0)1 60 78 70 90 • www.restek.fr<br />
Germany • phone: +49 (0)6172 2797 0 • fax: +49 (0)6172 2797 77 • www.restekgmbh.de<br />
Irel<strong>and</strong> • phone: +44 (0)2890 814576 • fax: +44 (0)2890 814576 • e-mail: restekirel<strong>and</strong>@aol.com<br />
Italy • phone: +39-02-7610037 • fax: +39-02-70100100 • www.superchrom.it<br />
Japan • phone: +81 (3)6459 0025 • fax: +81 (3)6459 0025 • e-mail: restekjapan@restek.com<br />
UK • phone: +44 (0)1494 563377 • fax: +44 (0)1494 564990 • www.thamesrestek.co.uk<br />
20