GRUNDFOS alldos<br />
product in<strong>for</strong>mation<br />
Oxiperm® <strong>164</strong> D <strong>for</strong> 5 <strong>to</strong> <strong>10</strong> g/h<br />
Preparation of chlorine dioxide from diluted solutions
Measurements<br />
Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />
Measurements<br />
Standard system<br />
DN20<br />
40<br />
700<br />
650<br />
Ø 9<br />
230<br />
148<br />
970<br />
930<br />
90<br />
DN20<br />
148<br />
4<strong>10</strong><br />
NaClO 2<br />
HCl<br />
System <strong>for</strong> batch operation<br />
800<br />
740<br />
Ø11<br />
260<br />
1300<br />
1260<br />
90<br />
178<br />
ca. 440<br />
NaClO 2<br />
HCl
Measurements<br />
Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />
Measurements<br />
Front installation system <strong>164</strong>-xxxDFI<br />
900<br />
800<br />
850<br />
750<br />
DN20<br />
90<br />
NaClO 2<br />
DN<br />
20<br />
90<br />
Ø <strong>10</strong><br />
HCl<br />
<strong>10</strong>2<br />
213<br />
Types<br />
ClO 2<br />
preparation<br />
capacity<br />
p max<br />
Consumption of<br />
components<br />
Consumption of bypass water [l/h]<br />
(input pressure < p max<br />
)<br />
Weight<br />
[bar] [l/h] continuous batch operation *)<br />
operation<br />
[g/h] 50 Hz 60 Hz HCl NaClO 2<br />
0.5 g/l 1 g/l 2 g/l [kg] Measurements in mm<br />
5 7 7 0.12 420 9.9 5.8 - 35 <strong>164</strong>-005D (DFI)<br />
<strong>10</strong> 7 6 0.24 420 19.8 9.6 4.6 35 <strong>164</strong>-0<strong>10</strong>D (DFI)<br />
*) In batch operation the concentration is freely adjustable between 0.5 and 1 g/l (<strong>164</strong>-005D) and 0.5 <strong>to</strong> 2 g/l (<strong>164</strong>-0<strong>10</strong>D).<br />
These systems are also available as front installation variants. Their designation is <strong>164</strong>-xxxDFI.<br />
Type
Technical data<br />
Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />
Technical data<br />
Adjustment of the preparation capacity<br />
Manual by menu-controlled opera<strong>to</strong>r prompting,<br />
au<strong>to</strong>matic by input signals<br />
Protection level • IP 65 electronics, dosing pumps, solenoid valve (option), flowmeter<br />
• IP 44<br />
• IP 67<br />
bypass pump (option)<br />
dosing controller<br />
Admissible concentration of chemicals • HCl 9 percent by weight<br />
Admissible<br />
• ambient temperature<br />
• operation water temperature<br />
• chemicals temperature<br />
Admissible relative air humidity<br />
Connection dilution water inlet<br />
Connection ClO 2<br />
solution<br />
Safety equipment<br />
• NaClO 2<br />
5 <strong>to</strong> 40 °C<br />
2 <strong>to</strong> 30 °C<br />
2 <strong>to</strong> 30 °C<br />
7.5 percent by weight<br />
max. 80 % at 40 °C, not condensing<br />
PVC pipe DN 20 / option: 3/4” NPT male thread<br />
PVC pipe DN 20 / option: 3/4” NPT male thread<br />
• Parallel moni<strong>to</strong>ring of capacity via dosing controller and internal Hall sensor signal<br />
<strong>for</strong> all dosing pumps<br />
Material Supporting rack PP<br />
Mounting parts stainless steel<br />
Reac<strong>to</strong>r<br />
grey PVC, lacquered stainless steel<br />
Post mixer<br />
grey PVC<br />
Pipes<br />
grey PVC<br />
Gaskets<br />
FPM/PTFE
Data<br />
Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />
Electrical and electronic data<br />
• Mains voltage 230 V / 50 Hz or 115 V / 60 Hz<br />
• Control: PLC<br />
• 4-line plain text display<br />
• Menu-controlled opera<strong>to</strong>r prompting<br />
• Flow-scheme with LED display showing mode and error signal<br />
Power consumption<br />
Analog inputs<br />
300 VA<br />
0(4) - 20 mA input or free configuration, max. 50 Ohm<br />
Digital inputs • Contact water meter, 1 <strong>to</strong> 45 pulses/sec. <strong>for</strong> control *)<br />
• MIN contact <strong>for</strong> main water<br />
• Remote On/Off<br />
• Error gas warning unit<br />
Analog outputs<br />
0(4) - 20 mA isolated output or free configuration, max. loop resistance 500 Ohm<br />
Potential-free outputs<br />
• Error messages<br />
• Pre-alert: chemicals empty<br />
• Au<strong>to</strong>matic/manual operation, max. charge 250 V, 6 A, max. 550 VA<br />
*) Note: The water meter has <strong>to</strong> be designed in a way that the number of input pulses <strong>for</strong> the control is between 1 - 45 pulses/sec.<br />
Versions<br />
• Bypass line with 3-way ball valve <strong>for</strong> manual reac<strong>to</strong>r rinsing<br />
Check valve (reac<strong>to</strong>r)<br />
• System backpressure less than 3 bars<br />
• System backpressure more than 3 bars<br />
Preparation system completely <strong>for</strong> wall mounting<br />
Options<br />
• With solenoid valve, with / without exhaust system<br />
• For batch operation, with / without exhaust system<br />
• With internal bypass pump, with / without exhaust system<br />
• With external centrifugal pump (provided by the cus<strong>to</strong>mer), with / without exhaust system<br />
Bus system<br />
• Modbus (RS 232 / RS 485)<br />
• Profibus DP module (on request)<br />
• Ethernet TCP/IP module (on request)<br />
Operating languages<br />
Standard: German<br />
Other languages can be selected with the software:<br />
• English, French, Spanish, Italian
Accessories<br />
Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />
Suction line systems<br />
• 2 suction lines with 2 tank covers<br />
• with empty signal and pre-alert<br />
Tank size Ø Tank opening Suction line<br />
30 l 45-46 mm 1.3 m, 2.5 m, 5 m<br />
60 l 45-46 / 57-58,5 mm 1.3 m, 2.5 m, 5 m<br />
Water extraction<br />
• Material: PVC<br />
Oxiperm version Connection Order<br />
system water supply<br />
number<br />
with solenoid valve/<br />
with bypass pump<br />
DN 20 G 1“ 521-<strong>164</strong>.2<br />
Batch operation DN 15 G 3/4“ 521-<strong>164</strong>.1<br />
Injection unit<br />
• Material: PVC<br />
Oxiperm version Connection Order<br />
system inject. unit<br />
number<br />
with solenoid valve/<br />
with bypass pump<br />
DN 20 R 1“ 522-232<br />
Batch operation DN 4/8/<strong>10</strong> R 3/4“ 522-<strong>164</strong>.1<br />
Spare parts sets<br />
<strong>for</strong> Oxiperm ®<br />
System pressure<br />
less than 3 bar more than 3 bar<br />
<strong>164</strong>-005D 553-688 553-688.1<br />
<strong>164</strong>-0<strong>10</strong>D 553-688 553-688.1
Installation drawings<br />
Oxiperm® <strong>164</strong> D / 5 <strong>to</strong> <strong>10</strong> g/h<br />
Oxiperm® <strong>164</strong> C<br />
with solenoid valve<br />
Oxiperm® <strong>164</strong> C<br />
with internal bypass pump<br />
8<br />
12<br />
7<br />
11<br />
3<br />
6<br />
12<br />
7<br />
3<br />
6<br />
9<br />
1<br />
1<br />
<strong>10</strong><br />
2<br />
<strong>10</strong><br />
2<br />
9<br />
5<br />
4<br />
5<br />
4<br />
NaClO<br />
2<br />
HCl<br />
NaClO<br />
2<br />
HCl<br />
Oxiperm® <strong>164</strong> C<br />
batch operation<br />
5<br />
1<br />
<strong>10</strong><br />
4<br />
9<br />
2<br />
1 Oxiperm® <strong>164</strong> D electronics<br />
2 Connection <strong>for</strong> bypass water input<br />
3 Connection <strong>for</strong> the ClO 2<br />
solution line output <strong>to</strong> the injection unit<br />
4 Suction line <strong>for</strong> the HCl dosing pump<br />
5 Suction line <strong>for</strong> NaClO 2<br />
dosing pump<br />
6 Shutt-off valve (by cus<strong>to</strong>mer)<br />
7 Sample extraction (by cus<strong>to</strong>mer)<br />
8 Check valve (by cus<strong>to</strong>mer),<br />
<strong>for</strong> operation with an internal bypass pump<br />
9 Shut-off valve <strong>for</strong> bypass water extraction (by cus<strong>to</strong>mer)<br />
<strong>10</strong> Exhaust system <strong>for</strong> supporting rack (option)<br />
11 Pressure loading valves (by cus<strong>to</strong>mer) <strong>for</strong> system backpressures<br />
< 1 bar<br />
12 Inductive flowmeter 4-20 mA or contact water meter <strong>for</strong> proportional<br />
control of the system<br />
Note:<br />
For protection of the drinking water supply, the cus<strong>to</strong>mer has <strong>to</strong><br />
provide a pipe disconnec<strong>to</strong>r (<strong>to</strong> DVGW, W624).<br />
NaClO 2<br />
HCl
Being responsible is our foundation<br />
Thinking ahead makes it possible<br />
Innovation is the essence<br />
91836411 0<strong>10</strong>8<br />
15.8<strong>10</strong>039 V7.0<br />
EN<br />
Subject <strong>to</strong> change<br />
© Grundfos Alldos<br />
Dosing & Disinfection<br />
ALLDOS Eichler GmbH<br />
www.grundfosalldos.com