Inverters<br />

OutBack Power <strong>Systems</strong><br />

<strong>Grid</strong> Interactive Inverters<br />

GTFX and GVFX inverters provide automatic backup power when utility outages occur. The FX<br />

inverter from OutBack Power has established itself in the off-grid world. Now they bring their<br />

expertise to the multi-purpose grid-tie market place with the GTFX and the GVFX models that provide<br />

automatic back-up power when utility outages occur. The GTFX is sealed and includes a turbo fan kit.<br />

GVFX models are vented and have no fan. Use of an MPPT controller such as the OutBack’s MX60<br />

will greatly increase the energy harvested from the PV array. Maximum of two GTFX or GVFX inverters<br />

can be connected in series for 240 Vac split phase output. All models are ETL listed to UL-1741.<br />

5-year warranty. Extended warranty available direct from manufacturer.<br />

VFX Inverter<br />

VFX Inverter, cover removed<br />

FX Series Inverters<br />

OutBack Power’s line-up of inverters has grown considerably over the past few years. Now six<br />

different power levels are offered at a variety of voltages ranging from 12 to 48 Vdc. All FX inverters<br />

offer pure sinewave output, a high current battery charger and AC transfer switch. Multiple pairs of<br />

FX inverters can be connected together (using HUB) configured for 220/240 Vac split phase output<br />

(using MATE) for a maximum of 10 inverters. Three FX inverters can be connected in parallel for<br />

120 Vac single phase output or configured for 208 Vac three-phase output. All models have a single<br />

60 Amp AC input and transfer relay. The gasketed die-cast aluminum chassis protects and keeps the<br />

power conversion components cool. Sealed units are water proof to IEC529 IP65 standards and have<br />

an operational temperature range of -40ºC to -60ºC. FX sealed inverters include external TURBO<br />

cooling system. “Bug-proof” vented version has stainless steel screens to protect the air intake<br />

and internal fan. The air inlet comes with a removable, washable foam filter insert. FX inverters are<br />

compatible with OutBack FLEXware enclosures and racks. Available in 120 Vac/60 Hz single phase,<br />

230 Vac/50 Hz versions and mobile versions with built-in AC neutral/ground switching system. FX<br />

series can surge two times their power rating. Call for more information.<br />

Part # Model Peak DC Voltage Continuous Charger Dimensions Shipping<br />

Efficiency% Input Power (Watts) Current (Amps) Weight<br />

Inverters<br />

Sealed<br />

715120 GTFX2524 91 24 2500 55 16.3 x 8.3 x 9.7 67<br />

715122 GTFX3048 91 (CEC) 48 3000 35 16.3 x 8.3 x 9.7 67<br />

715029 FX2012T 90 12 2000 80 16.3 x 8.3 x 13 67<br />

715152 FX2524T 92 24 2500 55 16.3 x 8.3 x 13 67<br />

715153 FX3048T 93 48 3000 35 16.3 x 8.3 x 13 67<br />

Vented<br />

715121 GVFX3524 91 24 3500 85 16.3 x 8.3 x 9.7 62<br />

715123 GVFX3648 91 (CEC) 48 3600 45 16.3 x 8.3 x 9.7 62<br />

715096 VFX2812 90 12 2800 125 16.3 x 8.3 x 12 64<br />

715097 VFX3524 92 24 3500 85 16.3 x 8.3 x 12 64<br />

715098 VFX3648 93 48 3600 45 16.3 x 8.3 x 12 64<br />

Sealed – 230Vac/50Hz<br />

715137 FX2012ET 90 12 2000 100 16.3 x 8.3 x 13 67<br />

715037 FX2024ET 92 24 2000 55 16.3 x 8.3 x 13 67<br />

715105 FX2348ET 93 48 2300 35 16.3 x 8.3 x 13 67<br />

Vented – 230Vac/50Hz<br />

715061 VFX2612E 90 12 2600 120 16.3 x 8.3 x 12 64<br />

715127 VFX3048E 92 24 3000 85 16.3 x 8.3 x 12 64<br />

715132 VFX3024E 93 48 3000 45 16.3 x 8.3 x 12 64<br />

OutBack HUB System<br />

OutBack Inverter Accessories<br />

HUB System Communications Managers<br />

The HUB system communications managers are the backbone of your networked OutBack power<br />

conversion system. The OutBack HUB communicates stacking, load share and power save off/on<br />

signals. Interconnection cabling is standard Ethernet CAT5 with RJ45 modular jacks. Through the<br />

use of a HUB, your system is completely coordinated and managed by the MATE. HUB4 allows four<br />

combined inputs of inverter with charge controllers, HUB10 permits up to 10 combined inputs.<br />