2 Pressure filter up to 2.5 bar working pressure 16<br />

MUNICH high-layer filter housing<br />

with a nozzle base<br />

The MUNICH high-layer filter series is fitted with single- and multi-layer filters and<br />

activated charcoal absorption filters, making it particularly suitable for installation in<br />

areas with very limited space or restricted height (compromise with DIN 19643/5).<br />

Special multi-layer filtration also optimises filter performance.<br />

BEHNCKE filter operating technology. Know-how for<br />

reduced energy and water consumption. For our future.<br />

• High-quality with its glass-fibre reinforced polyester resin<br />

with inner sealing<br />

• Large service openings top and side<br />

• Integrated nozzle base<br />

• Drain cock with hose connection<br />

• Pressure gauge and manual air bleeder<br />

• Sight glass 150 x 50 mm<br />

• Max. working temperature 40 °C<br />

• Working pressure 2.5 bar<br />

• 6-way backwash valve, optionally available with Besgo<br />

valve or with switch panel<br />

• Automatic ventilation and air bleed valves (optional)<br />

• Differential pressure gauge (optional)<br />

• Designed for general water treatment<br />

1<br />

2<br />

3<br />

MUNICH high-layer filter system<br />

• Complete with filter container made of glass-fibre reinforced<br />

polyester resin with inner sealing<br />

• Large service openings top and side DN 280/450<br />

• Integrated nozzle base<br />

• Drain cock with hose connection<br />

• Standard with 150 x 50 sight glass and pressure gauge<br />

• 2” backwash valve (600 d. + 800 d. containers)<br />

• Switch panel DN 125 (on the 1000 + 1200 d. containers)<br />

and front piping<br />

• Connection sizes in accordance with DIN 19643<br />

• Fully piped with a self-priming plastic filter pump (GS<br />

certified) and a large strainer mounted on a noise-absorbing<br />

plastic pallet<br />

• Max. working temperature 40 °C<br />

• Working pressure 2.5 bar<br />

• 3” 6-way valve (d600, 800) and switch panel (d1000, 1200)<br />

or Besgo automatic valve (optional)<br />

1 The integrated BEHNCKE nozzle base meets the most demanding<br />

2 Sight glass with MUNICH filter<br />

3 The nozzle base also conforms the standards for public operation<br />

(DIN 19643/19605)<br />

Filter material required for the MUNICH filter container<br />

with nozzle base<br />

• DIN filter sand<br />

• EN12904<br />

• Anthracite DIN EN12909<br />

• AFM (Activated Filter Material)