Chapter 5<br />
Fiber Optics Cable Field Calibration and Testing<br />
TESTING WITH FIBER STANDARDS<br />
Certification of Fiber Optic Cabling is typically performed in accordance with the TIA-<br />
568 or ISO 11801 Cabling Standards where a Pass/Fail criterion is based on the length<br />
of the cable and the number of splices and connectors in a fiber link. In addition to<br />
these criteria, <strong>LANTEK</strong> can be configured to perform application specific fiber tests,<br />
which are useful when trying to determine whether a fiber link will support specific<br />
types of networking equipment such as 100BaseSX or 1000BaseLX.<br />
To utilize these options, please follow the steps below:<br />
1. From the DH Ready Screen, press F3 or select the Fiber icon, press<br />
ENTER<br />
2. The Fiber Cable Type screen appears. Highlight the option corresponds to the<br />
installed adapters and select the softkey “Fiber Std.” or F2.<br />
3. Use the UP/DOWN ARROW Keys to highlight the desired standards for testing,<br />
and press ENTER.<br />
4. The Fiber Standards screen appears. Select the applicable core size (F1),<br />
wavelength (F2), and/or setting the loss budget (F3) keys. Upon completion,<br />
press ENTER.<br />
5. <strong>LANTEK</strong> units are now ready for testing with specified Fiber wavelength and<br />
standards.<br />
Note: With different Standards, different softkeys of operations are provided for test<br />
setup. Refer to Appendix C – Fiber Optic Cabling Standards & Application<br />
Requirement for specific Fiber Standards.<br />