Chapter 2<br />
Test Setup Procedures<br />
STANDARD CABLE ID<br />
If the Simple Cable ID option is not activated in the Preferences screen under Autotest<br />
Preference, you have further options available to set the required cable.<br />
Setting a Cable ID<br />
1. In the Cable ID screen, highlight Set ‘Cable From’.<br />
2. Press ENTER to open the screen.<br />
Figure 2-17: Cable ID Screens<br />
Note: The screen that appears will reflect the most recently assigned Cable ID (either<br />
Single or Double). Double ID is used in this example.<br />
3. Enter the following parameters as required:<br />
a. ‘Cable From’ name, twelve (12) characters maximum.<br />
b. Current, Start, and End point of the counter, four digits each. After reaching the<br />
End point the counter will be reset.<br />
c. Select the icon to activate a lock and to activate the Auto Increment<br />
feature for a character.<br />
‣ Select to go to the ‘Cable To’ screen. Repeat steps a, b and c.<br />
4. After entering the desired ‘Cable From’ and ‘Cable To’ names and parameters,<br />
press ENTER to save and return to the Main Cable ID screen.<br />
Test Counter<br />
In addition to the cable name, you can assign up to four characters to identify<br />
individual tests.<br />
‣ The icon<br />
‣ The icon<br />
below a digit designates a non-incrementing field.<br />
indicates an automatically incrementing field.<br />
The default numbering scheme is set to starts counting from 0000 and ends at 9999.<br />
Custom numbering schemes may be used. Table 2-2 and Table 2-3 contain some<br />
examples for counting Single and Double IDs.<br />