21.11.2013 Views

CANgate User's Manual - dataTaker

CANgate User's Manual - dataTaker

CANgate User's Manual - dataTaker

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Overload Errors<br />

If <strong>CANgate</strong> is heavily loaded (many slot definitions, rapid slot poll rate, fast host/CAN baud rates), errors such as:<br />

CAN1 RX OVERFLOW<br />

may be issued, indicating that one or more incoming CAN messages have been dropped. Even though these events are not<br />

reported in non-verbose mode, they are still counted, and the event counts may be displayed using the STATS command<br />

(P26).<br />

In a similar vein,<br />

PROC TIME OVERFLOW<br />

indicates that <strong>CANgate</strong> may not have satisfied the requested slot sample rate. This error may sometimes occur if a<br />

diagnostic command is entered that produces a large volume of output text (eg STATUS).<br />

Comms Errors<br />

If a large number of communications errors occur on a CAN port, the port will be briefly shut down and the following message<br />

returned (if in verbose mode):<br />

CAN1 BUS ERROR – DISCONNECTED<br />

The most common cause for this is an incorrectly configured bit rate, although it may also be caused by noise or an<br />

intermittent electrical connection. After two seconds <strong>CANgate</strong> will re-enable the port and attempt communication again.<br />

All comms errors on the CAN, host and GPS ports are counted and counts may be displayed using the STATS command<br />

(P26).<br />

Certain ECU responses will also be indicated via an error message (if in Verbose mode), eg.<br />

ISO14230 NEGATIVE REPLY – 11<br />

which in this case indicates that the requested service is not available.<br />

Internal Errors<br />

If the <strong>CANgate</strong> firmware detects a serious internal inconsistency it will force a hardware reset and display a message such<br />

as:<br />

DATA ABORT EXCEPTION AT 000049F8<br />

or<br />

INTERNAL ERROR 1 (00000008)<br />

Following the reset, <strong>CANgate</strong> will attempt to resume normal operation.<br />

If one of these errors ever occur, please note the circumstances of the failure and contact <strong>dataTaker</strong> support.<br />

UM-0086-A2 <strong>CANgate</strong> User’s <strong>Manual</strong> Page 36

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!