NSG 9000-6G - Harmonic Inc
NSG 9000-6G - Harmonic Inc
NSG 9000-6G - Harmonic Inc
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Chapter 4 Configuring Applications<br />
VOD Application<br />
NOTE: Do not change the default settings unless it is necessary. Changing the parameters may cause<br />
serious problems with elementary stream transmission.<br />
NOTE: Changing the PID Remapping mode is global. It applies to the platform and to both VOD and SDV<br />
sessions.<br />
<br />
To change PID remapping<br />
1. Select Applications > VOD > Settings:<br />
2. By default the remapping method is Paradigm. To change the remapping method, select<br />
Random.<br />
The PID Range (Per TS) option is enabled.<br />
3. In PID Range (Per TS), define the PID range (in hex-decimal format) that the <strong>NSG</strong> will use for<br />
random PID assignment. The range of acceptable values is 0x21 to 0x1FF0.<br />
NOTE: Changes take affect after device reset only.<br />
4.2.2.2 Pro:Idiom PID Remapping<br />
Pro:Idiom is an encryption system used in various cases, typically for hospitality video<br />
broadcast systems. The <strong>NSG</strong> is capable of processing and streaming Pro:Idiom pre-encrypted<br />
content. This entails:<br />
• Passing the Pro:Idiom ECM PID, and remapping it to an appropriate PID number<br />
• Passing a special Pro:Idion descriptor, with descriptor tag 0xAD (173 decimal)<br />
When streaming Pro:Idiom content, the <strong>NSG</strong> remaps Pro:Idiom PIDs to a user-configurable<br />
range of PIDs. To set the range of Pro:Idiom PID numbers, do the following:<br />
• In Pro:Idiom Base PID - enter the base PID to start the range for Pro:Idiom PIDs. The default<br />
base PID is 0x1050.<br />
4.2.2.3 Setting PAT/PMT Intervals<br />
1. In PMT Interval, define the interval in milliseconds at which PMT packets are sent over the<br />
<strong>NSG</strong>'s output transport streams.<br />
2. In PAT Interval, define the interval in milliseconds at which PAT packets are sent over the<br />
<strong>NSG</strong>'s output transport streams.<br />