Chapter 3 Configuring Platform Parameters<br />
Configuring NGOD<br />
Deletion Receipt - a string you need to record and use when approaching <strong>Harmonic</strong><br />
Customer Support.<br />
<br />
To organize the Available Licenses table<br />
• By default, the first raw of the table lists the license entered the latest. To arrange the<br />
records in a sequential order, click on any of the column names. An arrow appears to<br />
indicate the list order.<br />
3.15 Configuring NGOD<br />
When the EdgeQAM is part of an NGOD system architecture, you need to configure the<br />
following to allow the QAM-RFs of the EdgeQAM to outflow SDV/VOD sessions:<br />
• Configure and enable an NGOD ERM server as explained below.<br />
• Define the NGOD ERM as the QAM-RF manager of the required QAM-RFs. See 3.12.4<br />
Configuring/Viewing QAM Channels on page 49.<br />
Setting NGOD ERM parameters requires to set general and the ERM parameters.<br />
3.15.1 Configuring NGOD General Parameters<br />
To allow communication with the ERM, the <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> device supports the D6 and R6<br />
NGOD protocols. When communicating using the R6 protocol, <strong>NSG</strong> is always listening on<br />
port 554(RTSP).<br />
1. Select Platform > NGOD tab.<br />
2. Focus on the General section.<br />
3. In NGOD Component Name, enter the component name as defined in the D6 protocol.<br />
4. In Bandwidth Update Threshold (kbps), define the allowed deviation from the current output<br />
bit rate of the device (60 to 2000). Whenever the bit rate deviation reaches the value<br />
defined in this field, the <strong>NSG</strong> sends the ERM the updated output bit rate.<br />
5. In Routing Cost, enter a value as defined in the D6 protocol (0 to 255).<br />
6. In R6 RTSP Port, enter 554 as the port number. When communicating using the R6<br />
protocol <strong>NSG</strong> is always listening on port 554(RTSP).<br />
3.15.2 Configuring ERM Parameters<br />
1. Select Platform > NGOD tab.<br />
2. Click Add, to add an ERM.<br />
3. In IP Address, enter the ERM IP address.<br />
4. In Port, enter the ERM TCP port number.<br />
5. In Version, select the supported version of the protocol. Version 2 is the default version.<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 62 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B