Chapter 3 Configuring Platform Parameters<br />

RF Module Redundancy Overview<br />

• The QAM-RF module in slot nine only is not configured and is reserved for redundancy<br />

purposes. However, the QAM manager of all QAMs of module nine is Broadcast.<br />

• The Enable Module Redundancy option is selected<br />

Upon failure of any of the active modules, the backup module is automatically activated with<br />

the configuration of the faulty QAM-RF module. The typical fail-over time is between 10-20<br />

seconds.<br />

Use the RF module redundancy if the following applies:<br />

• All output RF ports of the <strong>NSG</strong><strong>9000</strong>-<strong>6G</strong> device are combined into a single RF network.<br />

• When relatively high availability at reasonable cost is required.<br />

NOTE: If high availability cannot be compromised, use 1:1 device redundancy. It provides protection<br />

against various failures and shorter fail-over time.<br />

3.13.1 RF Module Related Alarms<br />

Triggering Alarm<br />

A triggering alarm is any alarm that is critical and is issued by the QAM-RF module, or the<br />

upconverter as the following table lists:<br />

Table 3-12: <strong>NSG</strong><strong>9000</strong>-<strong>6G</strong> Triggering Alarms<br />

Object Alarm Description<br />

QAM-RF Module<br />

RF Port<br />

Critical Error<br />

Processing Error<br />

Temperature Out of<br />

Range<br />

Communication Failure<br />

Initialization Failure<br />

Communication Failure<br />

RF Level Out of Range<br />

PLL1 Failure<br />

PLL2 Failure<br />

Power Supply Failure<br />

Software Failure<br />

Internal fatal error in the QAM-RF modules<br />

QAM-RF global error<br />

The upconverter's temperature is out of<br />

the allowed temperature range: <br />

(0°C to 70°C)<br />

The device cannot communicate with the<br />

QAM-RF module<br />

Module initialization failed<br />

The device can not communicate with the<br />

upconverter.<br />

The power level of the RF signal going into<br />

the upconverter is out of the allowed range<br />

Indicates a HW failure<br />

Indicates a HW failure<br />

Power level to the upconverter<br />

momentarily exceeded its limit<br />

Indicates a HW failure<br />