Chapter 3 Configuring Platform Parameters<br />
RF Module Redundancy Overview<br />
• The QAM-RF module in slot nine only is not configured and is reserved for redundancy<br />
purposes. However, the QAM manager of all QAMs of module nine is Broadcast.<br />
• The Enable Module Redundancy option is selected<br />
Upon failure of any of the active modules, the backup module is automatically activated with<br />
the configuration of the faulty QAM-RF module. The typical fail-over time is between 10-20<br />
seconds.<br />
Use the RF module redundancy if the following applies:<br />
• All output RF ports of the <strong>NSG</strong><strong>9000</strong>-<strong>6G</strong> device are combined into a single RF network.<br />
• When relatively high availability at reasonable cost is required.<br />
NOTE: If high availability cannot be compromised, use 1:1 device redundancy. It provides protection<br />
against various failures and shorter fail-over time.<br />
3.13.1 RF Module Related Alarms<br />
Triggering Alarm<br />
A triggering alarm is any alarm that is critical and is issued by the QAM-RF module, or the<br />
upconverter as the following table lists:<br />
Table 3-12: <strong>NSG</strong><strong>9000</strong>-<strong>6G</strong> Triggering Alarms<br />
Object Alarm Description<br />
QAM-RF Module<br />
RF Port<br />
Critical Error<br />
Processing Error<br />
Temperature Out of<br />
Range<br />
Communication Failure<br />
Initialization Failure<br />
Communication Failure<br />
RF Level Out of Range<br />
PLL1 Failure<br />
PLL2 Failure<br />
Power Supply Failure<br />
Software Failure<br />
Internal fatal error in the QAM-RF modules<br />
QAM-RF global error<br />
The upconverter's temperature is out of<br />
the allowed temperature range: <br />
(0°C to 70°C)<br />
The device cannot communicate with the<br />
QAM-RF module<br />
Module initialization failed<br />
The device can not communicate with the<br />
upconverter.<br />
The power level of the RF signal going into<br />
the upconverter is out of the allowed range<br />
Indicates a HW failure<br />
Indicates a HW failure<br />
Power level to the upconverter<br />
momentarily exceeded its limit<br />
Indicates a HW failure<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 53 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B