Chapter 3 Configuring Platform Parameters<br />
Configuring/Viewing DTI Parameters<br />
<br />
<br />
In Active Port, view the currently active DTI port.<br />
In FPGA Version, view the installed FPGA version of the DTI client.<br />
4. To view DTI client port information, focus on the Per Port Information section. For each port<br />
view the following information:<br />
DTI Signal Detected - indicates whether a valid DTI signal is detected.<br />
<br />
<br />
<br />
<br />
Server Status - indicates the status of the server as it is communicated to the client.<br />
Available status indications are as follows: Warmup, Freerun, Fast, Normal, or<br />
Holdover.<br />
CRC Error Count - indicates the number of CRC error occurrences on the DTI link.<br />
Cable Advanced Valid - indicates whether cable advance is valid. A valid, i.e. Stable,<br />
Cable Advance value is essential in order for the client to lock to the server.<br />
Frame Error Rate - indicates the Frame Error Rate as follows: Below 2%, 2% to 5%, or<br />
Over 5%.<br />
3.11.2.1 DTI Client State Diagram<br />
Reboot<br />
Status = Warmup , changes<br />
to Freerun once oscillator<br />
stabilizes.<br />
Alarm: DTI Link Down<br />
Link Detected<br />
Status = Fast<br />
Alarm: DTI Not Locked<br />
Status = Bridging , changes to Holdover<br />
after a few seconds .<br />
Alarm: DTI Link Down<br />
Successful<br />
sync<br />
Link lost<br />
Status = Normal<br />
Status = Bridging , changes to Holdover<br />
after a few seconds.<br />
Alarm: DTI Not Locked<br />
Sync lost<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 41 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B