Chapter 3 Configuring Platform Parameters<br />
Configuring/Viewing DTI Parameters<br />
3.11 Configuring/Viewing DTI Parameters<br />
To configure and view DTI parameters, select the DTI component and do the following:<br />
• Configure DTI parameters:<br />
<br />
Enslave <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> clock to the DTI clock by selecting Use DTI Clock<br />
Define the DTI port redundancy mode, and select the preferred DTI port (if<br />
applicable, depending on the redundancy mode)<br />
Configure the SNMP traps<br />
• View the following:<br />
DTI client properties and status - via the Client Information section<br />
<br />
Port Information - via Per Port Information section<br />
3.11.1 Configuring DTI Client Parameters<br />
1. Select the Platform > General tab.<br />
2. In the Back Panel View, select the DTI component.<br />
The General tab appears.<br />
3. When working in M-CMTS mode, enslave the <strong>NSG</strong> clock to the DTI clock. To enslave,<br />
select Use DTI Clock.<br />
4. To set the DTI port redundancy mode, open the Redundancy Mode list and select one of<br />
the following:<br />
Manual - you need to select the DTI port. No automatic switching/activation of ports<br />
is done, regardless of the status of the DTI ports.<br />
Automatic (no Auto Revert) - selecting the active port is completely automatic,<br />
without any intervention and without any preference of a specific port. If the active<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 39 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B