Appendix D<br />
Control Panel<br />
D.1 Using the Control Panel<br />
You can set preliminary configuration and control the <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> unit via its front panel.<br />
The front panel includes a control panel comprised of a Liquid Crystal Display (LCD) and six<br />
buttons as the following figure shows:<br />
LCD Display Right key Up key Ok key<br />
Esc key<br />
Down key<br />
Left key<br />
D.1.1 Control Panel Display<br />
The 2-line, 16-character control panel display shows the screens, sub-screens, sub-screen<br />
options, error messages, warnings and alarms. The control panel display is comprised of two<br />
lines:<br />
Line 1 - displays the name of the current screen/sub-screen or selected option.<br />
Line 2 - displays the parameter value and all editing tasks are performed in this line. In editing<br />
mode the cursor is blinking to indicate the selected character.<br />
D.1.2 Control Panel Screen Concept<br />
The control panel screens are organized in a hierarchical fashion to indicate that a main<br />
screen contains sub-screens and sub-screen options. You may access a sub-screen only via<br />
its main screen. The available main screens are as follows:<br />
Power Up screen - A main screen that appears as soon as the <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> boots up and<br />
after a thirty minutes of inactivity. The screen shows the company’s name, <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> type<br />
and IP address.<br />
Network Config screen - allows to access sub-screens for ETH configuration.<br />
Setup screen - allows to reset the device.<br />
Alarm screen - displays the last active alarm or warning. You can browse through the alarms<br />
to view them.<br />
Product Information screen - via its sub-screens you can view information about the <strong>NSG</strong><br />
<strong>9000</strong>-<strong>6G</strong>.<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 148 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B