Chapter 6 Monitoring and Troubleshooting<br />

Monitoring <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> Status and Alarms<br />

Alarm Message<br />

Triggers<br />

Device<br />

Redundancy<br />

Description<br />

Solution<br />

CIC Overflow No The affected QAM-RF<br />

module has suffered<br />

repeated CIC overflow<br />

events. To prevent service<br />

interruption on adjacent<br />

QAM channels, both RF<br />

ports of the module has<br />

been shut-off.<br />

1. Replace the affected module.<br />

2. Call Customer Support.<br />

DTI port<br />

DTI Port Link Down<br />

DTI port lost connection<br />

with the DTI server<br />

Check DTI cable.<br />

CAS Privacy Mode<br />

ECM Nearing<br />

Expiration<br />

ECM is about to expire.<br />

Update PM ECM via MCT.<br />

DVB CAS<br />

SCS ECMG<br />

Connection Failure<br />

Connection to the ECMG<br />

has failed and services may<br />

not be encrypted properly<br />

• Check link of Ethernet port 2<br />

• Check ECMG definitions in the web<br />

client. Make sure all parameters<br />

match the properties of the CAS<br />

system in use.<br />

PID Range<br />

Backup Source<br />

Active<br />

No<br />

One of the backup sockets<br />

is activated<br />

Check source<br />

License<br />

License Expires in<br />

24 hours<br />

License will expire in the<br />

next 24 hours.<br />

Add and request a new license.<br />

License Expires in<br />

72 hours<br />

License will expire in the<br />

next 72 hours.<br />

Add and request a new license.<br />

Redundancy<br />

No Heartbeat on<br />

Eth1*<br />

Standby device does not<br />

receive Heartbeat<br />

messages from Eth1 of<br />

Active device.<br />

Check Ethernet connection.<br />

No Heartbeat on<br />

Eth2*<br />

Standby device does not<br />

receive Heartbeat<br />

messages from Eth2 of<br />

Active device.<br />

Check Ethernet connection.<br />

© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 121 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B