NSG 9000-6G - Harmonic Inc
NSG 9000-6G - Harmonic Inc
NSG 9000-6G - Harmonic Inc
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Chapter 6 Monitoring and Troubleshooting<br />
Monitoring <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> Status and Alarms<br />
Alarm Message<br />
Triggers<br />
Device<br />
Redundancy<br />
Description<br />
Solution<br />
Running on<br />
Temporary License*<br />
The system is running with<br />
an active temporary license<br />
while using the non-default<br />
features granted by the<br />
license.<br />
Claim the required license.<br />
GbE Port<br />
Backup Port Active<br />
Redundancy switch has<br />
taken place<br />
Check primary port<br />
Management<br />
Packets Reached<br />
Rate Limit<br />
Management packets may<br />
drop because rate is<br />
reaching its limit.<br />
Check non-video traffic on the GbE port<br />
SFP Communication<br />
Error<br />
Instable communication<br />
with the SFP module<br />
1. Verify that the SFP module is mounted<br />
properly<br />
2. Replace SFP<br />
3. Reset unit<br />
4. If problem persists, call Customer Support<br />
GbE Card<br />
Exceeding Max<br />
Sockets<br />
The number of incoming<br />
streams exceeds the<br />
allowed limit.<br />
Check the source.<br />
Extraction Buffer<br />
Overflow<br />
Extraction descriptor FIFO<br />
overrun.<br />
Check PSI bit rate.<br />
GbE Management<br />
Rx Failure<br />
Management traffic buffer<br />
overload resulting in<br />
management packets loss.<br />
Check the bit rate of the management<br />
packets.<br />
GbE Management Tx<br />
Failure<br />
Detecting problems when<br />
trying to transmit<br />
management data<br />
1. Reset unit.<br />
2. If problem persists, call Customer Support.<br />
TS Out<br />
Traffic on Invalid TS*<br />
The input traffic points to an<br />
invalid output.<br />
Check source and QAM mapping.<br />
Missing PSIP<br />
Configuration for TS<br />
PSIP is enabled and there is<br />
no PSIP configuration for<br />
the services. Services are<br />
transmitted with default<br />
PSIP configuration.<br />
Check PSIP configuration for correct service<br />
ID indication<br />
RF Port<br />
Nearing<br />
Temperature Out of<br />
Range<br />
The upconverter's<br />
temperature is almost out<br />
of the allowed temperature<br />
range:<br />
(0°C to 70°C).<br />
<br />
<br />
<br />
Check for proper operation of the cooling<br />
fans.<br />
Make sure that air inlets in the device's<br />
front panel are clean.<br />
If problem persists, power-off the device<br />
and contact Customer Support.<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 120 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B