Chapter 6 Monitoring and Troubleshooting<br />

Monitoring <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> Status and Alarms<br />

Alarm Message<br />

Triggers<br />

Device<br />

Redundancy<br />

Description<br />

Solution<br />

Running on<br />

Temporary License*<br />

The system is running with<br />

an active temporary license<br />

while using the non-default<br />

features granted by the<br />

license.<br />

Claim the required license.<br />

GbE Port<br />

Backup Port Active<br />

Redundancy switch has<br />

taken place<br />

Check primary port<br />

Management<br />

Packets Reached<br />

Rate Limit<br />

Management packets may<br />

drop because rate is<br />

reaching its limit.<br />

Check non-video traffic on the GbE port<br />

SFP Communication<br />

Error<br />

Instable communication<br />

with the SFP module<br />

1. Verify that the SFP module is mounted<br />

properly<br />

2. Replace SFP<br />

3. Reset unit<br />

4. If problem persists, call Customer Support<br />

GbE Card<br />

Exceeding Max<br />

Sockets<br />

The number of incoming<br />

streams exceeds the<br />

allowed limit.<br />

Check the source.<br />

Extraction Buffer<br />

Overflow<br />

Extraction descriptor FIFO<br />

overrun.<br />

Check PSI bit rate.<br />

GbE Management<br />

Rx Failure<br />

Management traffic buffer<br />

overload resulting in<br />

management packets loss.<br />

Check the bit rate of the management<br />

packets.<br />

GbE Management Tx<br />

Failure<br />

Detecting problems when<br />

trying to transmit<br />

management data<br />

1. Reset unit.<br />

2. If problem persists, call Customer Support.<br />

TS Out<br />

Traffic on Invalid TS*<br />

The input traffic points to an<br />

invalid output.<br />

Check source and QAM mapping.<br />

Missing PSIP<br />

Configuration for TS<br />

PSIP is enabled and there is<br />

no PSIP configuration for<br />

the services. Services are<br />

transmitted with default<br />

PSIP configuration.<br />

Check PSIP configuration for correct service<br />

ID indication<br />

RF Port<br />

Nearing<br />

Temperature Out of<br />

Range<br />

The upconverter's<br />

temperature is almost out<br />

of the allowed temperature<br />

range:<br />

(0°C to 70°C).<br />

<br />

<br />

<br />

Check for proper operation of the cooling<br />

fans.<br />

Make sure that air inlets in the device's<br />

front panel are clean.<br />

If problem persists, power-off the device<br />

and contact Customer Support.<br />

© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 120 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B