Chapter 6 Monitoring and Troubleshooting<br />
Monitoring <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> Status and Alarms<br />
Alarm Message<br />
Trigger<br />
Device<br />
Redundancy<br />
Description<br />
Solution<br />
ECM Stream Error No Cannot get ECM from ECMG • Check connectivity to ECMG<br />
• Check with the ECMG vendor<br />
that AC is valid<br />
DTI Card<br />
DTI Client Not<br />
Locked<br />
Yes<br />
The status of the DTI client is not<br />
NORMAL<br />
Check that DTI server status is<br />
NORMAL.<br />
Service Remux Session<br />
PAT Corrupted* No Invalid PAT Check source.<br />
PAT Missing* No PAT is missing in input signal. Check source<br />
PMT Corrupted* No Invalid PMT Check source<br />
PMT Missing* No PMT is missing in input signal. Check source<br />
Service Remux<br />
Source Failure*<br />
No<br />
When Service Remux is configured<br />
and the input socket is not active.<br />
Check source<br />
CMTS Session<br />
Socket CMTS Source<br />
Failure*<br />
No<br />
When CMTS socket is configured<br />
and the input socket is not active.<br />
Check source<br />
PID Remux Session<br />
PID Remux Source<br />
Failure*<br />
No<br />
When PID Remux is configured and<br />
the input socket is not active.<br />
Check source<br />
License<br />
License Expired No License expired Add and request a new license.<br />
6.3.3 Warning List<br />
The following table lists the warnings of <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong> according to the module that issues<br />
the warning. The warnings are arranged in alphabetical order with a short description and a<br />
solution to remit the warning. Warnings with a star are NOT reflected in NMX.<br />
Alarm Message<br />
Triggers<br />
Device<br />
Redundancy<br />
Description<br />
Solution<br />
Platform<br />
Nearing High<br />
Temperature<br />
The unit is close to<br />
overheating.<br />
Check front panel connection and the speed<br />
of the fans.<br />
NGOD D6<br />
Connection Loss<br />
NGOD VREP0-D6 server<br />
has lost connection and<br />
there are live SDV sessions<br />
within the <strong>NSG</strong>.<br />
Check the Ethernet connection to the D6<br />
server.<br />
© 2012 <strong>Harmonic</strong> <strong>Inc</strong>. 119 <strong>NSG</strong> <strong>9000</strong>-<strong>6G</strong>, Version 2.7, Rev B