Fig. 55-4 Unscrew all the plugs from control boards<br />

Fig. 55-7 Pay attention, that no cables will be crisped<br />

between box and front cover during closing!<br />

Fig. 55-5 Pull out the plugs of the control boards. Pull<br />

out selected control board. Insert new control board<br />

• Listen that both, the isolation plate at the side of<br />

equipment and the isolation plate at the side of soldering,<br />

were inserted!<br />

Fig. 55-8 Carefully close the control box with the front<br />

cover, and fix the four screws<br />

• Put on plugs X2…X6, fix the screws of the plugs and<br />

switch on control voltage.<br />

Checking the breaker:<br />

• Make 3 times ON /OFF switching in the „Test-position“<br />

of the draw out version/the installation. The breaker<br />

has to switch ON/OFF without any time lag.<br />

• If the test succeeds, reconnect the breaker to the<br />

main circuit.<br />

Fig. 55-6 Plug in all control plugs and tighten it by the<br />

bolts<br />