25.10.2012 Views

Liquefaction co-processing of coal shale oil at - Argonne National ...

Liquefaction co-processing of coal shale oil at - Argonne National ...

Liquefaction co-processing of coal shale oil at - Argonne National ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

I<br />

waxes (12% <strong>of</strong> <strong>oil</strong>) were very Impure and so were subjected to a se<strong>co</strong>nd dewaxing<br />

procedure similar to the first except th<strong>at</strong> the solvent used was 100 mL <strong>of</strong> a 70/30<br />

vlv mixture <strong>of</strong> acetone and toluene. This product was a very hard brown waxy<br />

sol id.<br />

Urea Dewaxinq<br />

I<br />

One <strong>oil</strong> sample was dewaxed by the urea adduction method. About 509 <strong>of</strong> the <strong>oil</strong><br />

was weighed and diluted with an equal weight <strong>of</strong> CH,CI, (MCB reagent). To this<br />

mixture was slowly added about 50 mls <strong>of</strong> an aqueous solution <strong>of</strong> urea (Fisher<br />

certified) s<strong>at</strong>ur<strong>at</strong>ed <strong>at</strong> 80°C which crystallized upon <strong>co</strong>oling on <strong>co</strong>ntact with the<br />

I<br />

<strong>oil</strong>/CH,CI, solution. The mixture was stirred for one hour, filtered in a Buchner<br />

funnel equipped with a glass-fiber filter, then washed with several aliquots <strong>of</strong><br />

CH,CI,. This filtr<strong>at</strong>e was set aside. The filter-cake was washed with warm w<strong>at</strong>er<br />

to dissolve the urea leaving the waxes on the filter. The w<strong>at</strong>er wash was<br />

I discarded. The waxes were washed through the filter with freshly distilled THF.<br />

The CH,CI, and THF filtr<strong>at</strong>es were stripped <strong>of</strong> solvent by rotary evapor<strong>at</strong>ion to<br />

produce the dewaxed <strong>oil</strong> and the waxes, respectively, which were weighed and<br />

analyzed. The product wax was a white solid.<br />

Solvent Quality (Microautoclave) Tests<br />

Samples were tested for their effectiveness as <strong>co</strong>al liquefaction donor solvents using<br />

a standard microautoclave test. This test, called the modified equilibrium test, has<br />

been described in detail previously (3). Briefly, 69 <strong>of</strong> a standard <strong>co</strong>al and 9g <strong>of</strong><br />

the sample to be tested are he<strong>at</strong>ed t5 75OOF for 30 min without added gas in a 30<br />

mL microautoclave. The <strong>co</strong>ntents are <strong>co</strong>oled and extracted with THF to determine<br />

the <strong>co</strong>nversion <strong>of</strong> <strong>co</strong>al to solubles. This test is an authentic <strong>co</strong>al liquefaction<br />

experiment. Solvent effects can be tested easily because there is no interfering<br />

c<strong>at</strong>alyst or extraneous gas present. The results <strong>of</strong> this test serve as an empirical<br />

measure <strong>of</strong> donor solvent quality. Coal <strong>co</strong>nversions obtained with several pure<br />

model <strong>co</strong>mpounds follow: n-tetradecane, 25.4%, 1-methylnaphthalene, 48.2%.<br />

tetralin, 85.4%. This test is reproducible to 1.2% absolute [standard devi<strong>at</strong>ion).<br />

Other Analyses<br />

Samples were analyzed by IH-NMR using a procedure described in detail elsewhere<br />

(2) to determine the effectiveness <strong>of</strong> dewaxing and to determine the purity <strong>of</strong> the<br />

waxes. Briefly, the H-NMR spectrum is divided in regions roughly <strong>co</strong>rresponding<br />

to different proton types. For example, the region between 10.0 and 4.7 ppm is<br />

assigned to arom<strong>at</strong>ic protons and the region between 1.4 and 0.5 ppm is assigned to<br />

to paraffinic protons. Paraffinic protons are protons on internal -CH,- groups or<br />

-CH, groups <strong>of</strong> paraffins and long alkyl chains. Reproducibility is 0.2% absolute<br />

(standard devi<strong>at</strong>ion).<br />

Gas chrom<strong>at</strong>ography [CC) was performed with a Perkin-Elmer Sigma 2000 instrument<br />

equipped with dual flame ioniz<strong>at</strong>ion detectors. The <strong>co</strong>lumn, a 30m x 0.25mm DB-5<br />

<strong>co</strong>lumn from JLW Scientific, was initially <strong>at</strong> 5OoC for 4 min, then programmed to<br />

280OC <strong>at</strong> 4OClmin and held for 20 min. Carrier gas was 20 psig H,. injector and<br />

detector temper<strong>at</strong>ures were 300OC. A split injection <strong>of</strong> 0.2pL <strong>of</strong> sample (O.lg/mL in<br />

THF) was used.<br />

internal standard.<br />

Quantit<strong>at</strong>ion was based on peak areas referred to an n-decane<br />

I Elemental analyses (C, H, N and S) were performed with Le<strong>co</strong> CHN-600 and SC32<br />

Instruments. Though these instruments were designed for the analysis <strong>of</strong> <strong>co</strong>als,<br />

not <strong>oil</strong>s, reliable N and S determin<strong>at</strong>ions can be made. C and H values are less<br />

reliable, but are probably accur<strong>at</strong>e to ?l% absolute.<br />

Feed Oils<br />

All samples were authentic <strong>co</strong>al liquefaction recycle <strong>oil</strong>s.<br />

259

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!