Uninterruptible Power Supplies - G E Power Controls
Uninterruptible Power Supplies - G E Power Controls
Uninterruptible Power Supplies - G E Power Controls
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
UPS<br />
SG Series - double conversion UPS<br />
SG 80<br />
Dimensions<br />
(hxwxd, mm)<br />
Net<br />
weight<br />
(kg)<br />
Ref. No.<br />
Order codes<br />
SG 80 kVA without battery, with 6 pulse rectifier<br />
SG 80 kVA without battery, with 6 pulse rectifier, with Class A EMI filter<br />
SG 80 kVA without battery, prepared for 12 pulse rectifier<br />
SG 80 kVA without battery, prepared for 12 pulse rectifier, with Class A EMI filter<br />
RPA kit installed in factory<br />
5th harmonic filter in UPS cabinet for THDi < 8%<br />
5th and 11th harmonic filter in UPS cabinet for THDi < 6%<br />
12 pulse rectifier without galv. separation in separate cabinet<br />
12 pulse rectifier with galv. separation in separate cabinet<br />
Input isolation transformer in separate cabinet<br />
Battery fuse box (without fuses)<br />
Battery fuses for SG 80 kVA<br />
Output cabinet 2x<br />
Output cabinet 3x<br />
Output cabinet 4x<br />
Battery solutions, 10 year lifetime, matching cabinets (1)<br />
Battery 1x75 Ah, runtime 6 minutes<br />
Battery 1x82 Ah, runtime 11 minutes<br />
Battery 2x92 Ah, runtime 33 minutes<br />
Battery 2x130 Ah, runtime 47 minutes<br />
Battery 3x110 Ah, runtime 63 minutes<br />
1820x800x800<br />
1820x800x800<br />
1820x800x800<br />
1820x800x800<br />
-<br />
-<br />
-<br />
1820x500x800<br />
1820x500x800<br />
1820x500x800<br />
600x400x200<br />
-<br />
1820x800x800<br />
1820x800x800<br />
1820x800x800<br />
1x 1820x1200x800<br />
1x 1820x1200x800<br />
2x 1820x1200x800<br />
2x 1820x1650x800<br />
3x 1820x1200x800<br />
605<br />
605<br />
605<br />
605<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
990<br />
1170<br />
2460<br />
3360<br />
4230<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
A<br />
SG 100<br />
B<br />
X<br />
SG 100 kVA without battery, with 6 pulse rectifier<br />
SG 100 kVA without battery, with 6 pulse rectifier, with Class A EMI filter<br />
SG 100 kVA without battery, prepared for 12 pulse rectifier<br />
SG 100 kVA without battery, prepared for 12 pulse rectifier, with Class A EMI filter<br />
RPA kit installed in factory<br />
5th harmonic filter in UPS cabinet for THDi < 8%<br />
5th and 11th harmonic filter in UPS cabinet for THDi < 6%<br />
12 pulse rectifier without galv. separation in separate cabinet<br />
12 pulse rectifier with galv. separation in separate cabinet<br />
Input isolation transformer in separate cabinet<br />
Battery fuse box (without fuses)<br />
Battery fuses for SG 100 kVA<br />
Output cabinet 2x<br />
Output cabinet 3x<br />
Output cabinet 4x<br />
1820x1200x800<br />
1820x1200x800<br />
1820x1200x800<br />
1820x1200x800<br />
-<br />
-<br />
-<br />
1820x500x800<br />
1820x500x800<br />
1820x500x800<br />
600x400x200<br />
-<br />
1820x800x800<br />
1820x800x800<br />
1820x800x800<br />
830<br />
830<br />
830<br />
830<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
Battery solutions, 10 year lifetime, matching cabinets (1)<br />
Battery 1x82 Ah, runtime 8 minutes<br />
Battery 1x130 Ah, runtime 15 minutes<br />
Battery 2x110 Ah, runtime 31 minutes<br />
Battery 3x110 Ah, runtime 48 minutes<br />
Battery 3x130 Ah, runtime 61 minutes<br />
1x 1820x1200x800<br />
1x 1820x1650x800<br />
2x 1820x1200x800<br />
3x 1820x1200x800<br />
3x 1820x1650x800<br />
1170<br />
1680<br />
2820<br />
4230<br />
5040<br />
*<br />
*<br />
*<br />
*<br />
*<br />
SG 120<br />
SG 120 kVA without battery, with 6 pulse rectifier<br />
SG 120 kVA without battery, with 6 pulse rectifier, with Class A EMI filter<br />
SG 120 kVA without battery, prepared for 12 pulse rectifier<br />
SG 120 kVA without battery, prepared for 12 pulse rectifier, with Class A EMI filter<br />
RPA kit installed in factory<br />
5th harmonic filter in UPS cabinet for THDi < 8%<br />
5th and 11th harmonic filter in UPS cabinet for THDi < 6%<br />
12 pulse rectifier without galv. separation in separate cabinet<br />
12 pulse rectifier with galv. separation in separate cabinet<br />
Input isolation transformer in separate cabinet<br />
Battery fuse box (without fuses)<br />
Battery fuses for SG 120 kVA<br />
Output cabinet 2x<br />
Output cabinet 3x<br />
Output cabinet 4x<br />
1820x1200x800<br />
1820x1200x800<br />
1820x1200x800<br />
1820x1200x800<br />
-<br />
-<br />
-<br />
1820x500x800<br />
1820x500x800<br />
1820x500x800<br />
600x400x200<br />
-<br />
1820x800x800<br />
1820x800x800<br />
1820x800x800<br />
830<br />
830<br />
830<br />
830<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
*<br />
Battery solutions, 10 year lifetime, matching cabinets (1)<br />
Battery 1x82 Ah, runtime 5 minutes<br />
Battery 1x130 Ah, runtime 10 minutes<br />
Battery 2x130 Ah, runtime 30 minutes<br />
Battery 3x130 Ah, runtime 46 minutes<br />
Battery 4x130 Ah, runtime 66 minutes<br />
1x 1820x1200x800<br />
1x 1820x1650x800<br />
2x 1820x1650x800<br />
3x 1820x1650x800<br />
4x 1820x1650x800<br />
1170<br />
1680<br />
3360<br />
5040<br />
6720<br />
*<br />
*<br />
*<br />
*<br />
*<br />
(1) All runtimes based on nominal load, PF 0.8<br />
* For ordering please contact customer service.<br />
B.28