oiler as it is a fresh steam condensate. The condensate from Second, Third, Fourth effect and surface condensers condensate is collected in a condensate tank. The condensate is transferred to the further treatment/drain by using centrifugal pump. The system operates under pressure and vacuum. Water-ring vacuum pumps are used to maintain a desired vacuum in the last effect. The last effect is at lowest temperature. Cooling water from cooling tower is used in the surface condensers for condensing the vapours from the last effect. The steam condensate from first effect shell is collected in condensate tank and is pumped back to the Boiler Brief note on Distillery ETP The spent wash generated from Distillation is highly polluted in nature, as it is acidic in content. It adversely affects the flora and fauna. In view of the above, for effective control of pollution, Effluent Treatment Plant is required: The treatment plant for effluent treatment comprises as under: (a) Primary treatment plant: - The spent wash is treated in closed tank with the help of Methane forming bacteria. The organic matter is degraded by Methane forming bacteria in to Biogas, which is highly inflammable as it contains 60-65% CH4 content, used as fuel in the Boiler. (b) Secondary treatment plant: - To bring the above effluent to desired norms of Pollution Control Board, further treatment plant is required i.e., Secondary treatment plant based on Activated Sludge process and followed by extended aeration. The effluent from primary treatment plant is fed in to this plant. This plant comprises following different units: 1. Aeration Tanks. 2. Clarifier. 3. Extended Aeration tank 4. Clarifier 5. Sludge drying beds The secondary treatment is based on Aeration; The Aerators are provided to the tank and agitate the liquid with the result that the Aerobic bacteria degrade the organic matter. (c ) Bio composting: As per requirement of the Ministry of Environment & Forests, to avail zero pollution, the only process available at present is Bio Composting. The effluent after Primary treatment plant is taken in Bio composting. The conversion of effluent into solid waste is done with the help of solid residue of Sugar mill waste known as press mud. The press mud is having all available nutrients for plant growth, the Bio methanated waste water also contains organic matter which is left and degraded is sprayed over Press mud. The Biocompost process completes in 45 / 60 Days time. 85

oiler as it is a fresh steam condensate. The condensate from Second, Third, Fourth effect and<br />

surface condensers condensate is collected in a condensate tank. The condensate is transferred<br />

to the further treatment/drain by using centrifugal pump.<br />

The system operates under pressure and vacuum. Water-ring vacuum pumps are used to<br />

maintain a desired vacuum in the last effect. The last effect is at lowest temperature. Cooling<br />

water from cooling tower is used in the surface condensers for condensing the vapours from the<br />

last effect. The steam condensate from first effect shell is collected in condensate tank and is<br />

pumped back to the Boiler<br />

Brief note on Distillery ETP<br />

The spent wash generated from Distillation is highly polluted in nature, as it is acidic in content.<br />

It adversely affects the flora and fauna. In view of the above, for effective control of pollution,<br />

Effluent Treatment Plant is required:<br />

The treatment plant for effluent treatment comprises as under:<br />

(a)<br />

Primary treatment plant: - The spent wash is treated in closed tank with the help of<br />

Methane forming bacteria. The organic matter is degraded by Methane forming bacteria<br />

in to Biogas, which is highly inflammable as it contains 60-65% CH4 content, used as<br />

fuel in the Boiler.<br />

(b) Secondary treatment plant: - To bring the above effluent to desired norms of<br />

Pollution Control Board, further treatment plant is required i.e., Secondary treatment<br />

plant based on Activated Sludge process and followed by extended aeration.<br />

The effluent from primary treatment plant is fed in to this plant. This plant comprises following<br />

different units:<br />

1. Aeration Tanks.<br />

2. Clarifier.<br />

3. Extended Aeration tank<br />

4. Clarifier<br />

5. Sludge drying beds<br />

The secondary treatment is based on Aeration; The Aerators are provided to the tank and<br />

agitate the liquid with the result that the Aerobic bacteria degrade the organic matter.<br />

(c ) Bio composting: As per requirement of the Ministry of Environment & Forests, to avail<br />

zero pollution, the only process available at present is Bio Composting.<br />

The effluent after Primary treatment plant is taken in Bio composting. The conversion of effluent<br />

into solid waste is done with the help of solid residue of Sugar mill waste known as press mud.<br />

The press mud is having all available nutrients for plant growth, the Bio methanated waste water<br />

also contains organic matter which is left and degraded is sprayed over Press mud.<br />

The Biocompost process completes in 45 / 60 Days time.<br />

85