<strong>GE</strong><br />
<strong>Measurement</strong> & <strong>Control</strong><br />
x|pipe BT<br />
Inline Radioscopic System for Boiler Tube Weld Inspection<br />
Small footprint, motorized solution, capable of producing high quality weld images.<br />
imagination at work
x|pipe BT provides a complete solution using <strong>GE</strong>’s DXR250RT digital detector array and Isovolt Titan E<br />
x-ray generator tube imaging chain, integrated with a protection cabinet and manipulation for inline<br />
inspection of butt welded boiler tubes. This solution also features a sophisticated data management<br />
system through <strong>GE</strong>’s Rhythm software handling data acquisition, image review and interpretation as<br />
well as reporting, long-term archive and retrieval.<br />
Key Features and Benefits<br />
• Patent-pending swivel cabinet design to account for<br />
+/- 45 degree imaging requirements<br />
• Optimized imaging chain: DXR250RT, Isovolt Titan<br />
E generator and tube options to optimize image<br />
quality, throughput and cost<br />
• Pneumatically-operated IQI holder allowing for IQI<br />
placement and viewing in each inspection image<br />
• Complete turnkey system with minimized footprint,<br />
forklift mobility and easy installation<br />
• Platform solution with single cabinet design for<br />
225kV and 320kV versions, facilitating upgrade path<br />
• Rhythm-enabled workflow & data archiving and<br />
enterprise data management through industrystandard<br />
DICONDE formats and protocols<br />
x|pipe BT in Closed Condition<br />
x|pipe BT in Open Condition<br />
Product Specifications<br />
• Productivity: Typical workflow can support up to 250 joints inspections/day<br />
• Product size: Can support minimum lengths of 4m, diameters from 30-100mm and wall thickness<br />
ranging from 4-15mm<br />
• Radiation protection cabinet: 225 kV system, with 320kV option, designed in accordance with the<br />
AERB guideline (India)<br />
• Image retention: Facilitates long-term archive and storage, in alignment with typical industry<br />
requirements of 5 years, through DICONDE formats and protocols
Technical Specifications<br />
x|pipe BT 320HP x|pipe BT 320STD x|pipe BT 225HP<br />
Specifications Related to X-Ray<br />
Maximum Tube Voltage 320KV 320KV 225KV<br />
Maximum Anode Dissipation 1800 W, 800 W 1600W, 640W 1800 W, 800 W<br />
Tube Current at Max. Tube<br />
Voltage<br />
5.6 mA, 2.5 mA 5 mA, 2 mA 8.0 mA, 3.5 mA<br />
Focal Spot Size (EN 12 543) 1.0 mm 0.4 mm 3.6mm, 1.9mm 1.0 mm 0.4 mm<br />
Emergent Beam Angle 30° x 40° 40° 30° x 40° (Assy)<br />
Inherent Filtration 3 mm Be 3 mm Be 0.8 mm Be + 2 mm Al<br />
Tube Model/Type MXR 320 HP/11 MXR 320/23 ISOVOLT 225 MM2/HP<br />
x|pipe BT 320HP, x|pipe BT 320STD and x|pipe BT 225HP<br />
Specifications Related to DR<br />
Detector<br />
DXR250RT<br />
Pixel Pitch (Static)<br />
200 micron<br />
Pixel Pitch (@30)Frames/Second 200 micron<br />
Scintillator<br />
CsI<br />
Active Area<br />
8”x8”<br />
A/D Conversion<br />
14 bits<br />
Image Lag<br />
Dimensions<br />
*All dimensions are in millimeters.<br />
This is not a completely closed system as there are openings for pipe entry and exit. A significant amount of scattered radiation always travels to<br />
certain distance along the length of the tubes. Safety fence must surround the system to ensure that the radiation level outside the fence is within<br />
the regulatory acceptance level (ie < 1µSv/hr). The leakage radiation at the fence level is less than 1 µSv/hr.<br />
<strong>GE</strong><br />
<strong>Measurement</strong> & <strong>Control</strong><br />
Building No 7A, 4th Floor<br />
DLF Cyber City, DLF Phase III<br />
Sector 25A, Gurgaon 122002<br />
marcom.mcindia@ge.com<br />
www.ge-mcs.com<br />
© 2013 General Electric Company. All Rights Reserved. Specifications subject to change without prior notice. Other company or product names mentioned in this document may be trademarks or registered<br />
trademarks of their respective companies, which are not affiliated with <strong>GE</strong>.