The maximum achievable outflow water temperature is decreased either by the thermostat<br />

switch-off tolerance or water armature, distribution pipeline length and thermal insulation as well.<br />

11.<br />

THERMOSTAT KNOB ADJUSTMENT<br />

Knob adjustment for EOV x.1, ELOV x.1, OVK x.1, LOVK x.1 type heaters:<br />

- Water frost-protection fuse<br />

approximately 7 °C (Adjustment<br />

for occasional heater operation,<br />

especially in winter)<br />

- temperature approximately 40 °C<br />

- economic operation<br />

approximately 55 - 60 °C<br />

- temperature approximately 80 °C<br />

Knob adjustment for an EOV x.2 type heater:<br />

Water frost-protection fuse, the<br />

appliance heats if the water<br />

temperature drops below<br />

approximately 15 °C.<br />

economy mode with water<br />

temperature of approximately 50 °C.<br />

maximum power, choose<br />

only if maximum water<br />

temperature is needed<br />

Knob adjustment for EOV 200, ELOV 200, OVK 120, OVK 150, OVK 200, LOVK 120, LOVK 150 and LOVK 200 type<br />

heaters:<br />

- Water frost-protection fuse<br />

approximately 7 °C (Adjustment<br />

for occasional heater operation<br />

especially in winter)<br />

- temperature approximately 40 °C<br />

- economy operation<br />

at approximately 55 - 60 °C<br />

- temperature approximately 80 °C.<br />

12.<br />

TEMPORARY HEATER INACTIVITY<br />

For several days of heater inactivity we recommend setting the thermostat knob at the position between the thinnest<br />

arrow position and the “E” symbol.<br />

For longer inactivation:<br />

- During summer and anyplace where the temperature of the room with the installed heater, including summer,<br />

does not fall bellow zero, shut down the electricity supply.<br />

- During winter, the heater should be connected to the electrical network and the thermostat knob should be set at<br />

the thinnest arrow line.<br />

13.<br />

HEATER MAINTENANCE<br />

For correct function and safety, and for long-term operation it is necessary, at least once every two years, to contact the<br />

service centre to check the heater and the anode rod wear. If the bar is worn out, replacement should be performed.<br />

Limescale forms in the boiler during operation while the formation velocity is dependant on the water hardness and the<br />

temperature to which the water is heated, as well as on the volume of water consumed and its temperature.<br />

A limescale layer deteriorates heat transmission between the heating body and the water, due to<br />

which the water heating itself decreases and burn-out of the heating element spiral can occur.<br />