Blast Chillers & Freezers - Foster Spares & Service
Blast Chillers & Freezers - Foster Spares & Service
Blast Chillers & Freezers - Foster Spares & Service
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
GB<br />
FOOD PROBE2 (FOOD 2) Food probe 3 operation – used for information / HACCP purposes only.<br />
FOOD PROBE3 (FOOD 3) Food probe 3 operation – used for information / HACCP purposes only.<br />
CONDENSER (COND) Condenser probe operation (chill cycles will only be time based)<br />
Light Mode Light Control Mode:<br />
Not Used (NON) Light Control Mode disabled (always off)<br />
DI Open (DI OPN) Light output is switched on when door is opened (if ‘Digital I/P 2’ = ‘LIGHT’)<br />
Func. NON<br />
DI Closed (DI CLS) Light output is switched on when door is closed (if ‘Digital I/P 2’ = ‘LIGHT’)<br />
Door Open (DR OPN) Light output is switched on when door is opened (if ‘Digital I/P 2’ = ‘DOOR’)<br />
Door Closed (DR CLS) Light output is switched on when door is closed (if ‘Digital I/P 2’ = ‘DOOR’)<br />
Language Controller Language setting:<br />
English (ENG) Text will be displayed in English Language<br />
French (FRA) Text will be displayed in French Language<br />
Func. ENG<br />
German (ALL) Text will be displayed in German Language<br />
Italian (IT) Text will be displayed in Italian Language<br />
Clock Format 12 or 24 hr. Display/Setting format for the time clock. Func. 24hr<br />
Daylight Sav. Time Daylight Saving time adjustment on last Sunday in March (reverts lack last<br />
NO or YES<br />
Func. YES<br />
Sunday in October)<br />
Screensaver tmt<br />
Time before starting screensaver from Home page (with value ‘Scn Svr Time’<br />
0 to 120 min<br />
Min. 0<br />
= ‘0’ screensaver is not enabled and display remains constantly illuminated)<br />
Air Probe Offset -9.9 to 9.9° Air Temperature probe (T1) offset. °K 0<br />
Evp. Probe Enable NO or YES Evaporator (T2) probe enabling (via T2 port) Flag YES<br />
Evp Probe Offset -9.9 to 9.9° Evaporator temperature probe (T2) offset (when ‘Evp Prb Offset’ = YES’) °K 0<br />
Food Probe Enable NO or YES Food insertion (T3) probe enabling (via T3 port) Flag YES<br />
Food Probe Offset -9.9 to 9.9° Food probe 1 offset (when ‘Food Prb Enable’ = ‘YES’) °K 0<br />
Food 2 Probe<br />
-9.9 to 9.9° Food Probe 2 offset (if ‘Digital I/P1’ = ‘FOOD’) °K 0<br />
Offset<br />
Food 3 Probe<br />
-9.9 to 9.9° Food Probe 2 offset (if ‘Digital I/P1’ = ‘FOOD3’) °K 0<br />
Offset<br />
Cond. Probe Offset -9.9 to 9.9° Condenser probe offset (when 'Digital input 1' or 'Digital input 2' = 'COND'). °K 0<br />
Display Scale Readout scale:<br />
0.1°C (0.1°C) Range -50 to 120°C (0.1°C resolution within -9.9 to +9.9°c)<br />
Func. 0.1°C<br />
1°C (1°C) Range -50 to 210°C<br />
1°F (1°F) Range -50 to 210°F<br />
Thermal<br />
0 to 100 Displayed temperature slowdown Func. 0<br />
Simulation<br />
Address 1 to 255 FC1-11 address for PC/ FCOM/ DL28W communication Flag 1<br />
System 1<br />
System 2<br />
18