QuickSpecs <strong>HP</strong> <strong>HP</strong> <strong>ProLiant</strong> <strong>ProLiant</strong> <strong>DL380</strong> <strong>DL380</strong> <strong>Generation</strong> <strong>Generation</strong> 6 6 (<strong>G6</strong>) (<strong>G6</strong>)<br />

(<strong>G6</strong>)<br />

Standard Features<br />

x16 x16 PCIe PCIe Riser<br />

Riser<br />

(Optional Secondary)<br />

Storage Storage Controller Controller<br />

Controller<br />

One of the following<br />

depending on Model<br />

1 PCIe Gen2 x16 x16 13 Full Length,<br />

Full Height<br />

slot<br />

* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus<br />

assignment number<br />

** Indicates the number of physical electrical lanes running to the connector.<br />

Expansion Expansion<br />

Expansion<br />

Slots Slots #<br />

#<br />

Technology Technology Bus<br />

Bus<br />

Width Width** Width Width<br />

Connector Connector<br />

Connector<br />

Width<br />

Width<br />

Supports up<br />

to 225W;<br />

single wide<br />

cards only<br />

Bus Bus Number Number* Number Form Form Form Factor Factor Notes<br />

Notes<br />

4 PCIe Gen2 x16 x16 16 Full Length,<br />

Full Height<br />

slot<br />

* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus<br />

assignment number<br />

** Indicates the number of physical electrical lanes running to the connector.<br />

Entry Models <strong>HP</strong> Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0)<br />

Base Models <strong>HP</strong> Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0)<br />

Supports up<br />

to 225W;<br />

single wide<br />

cards only<br />

Performance Models <strong>HP</strong> Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0/6)<br />

High Efficiency Models <strong>HP</strong> Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0)<br />

Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array<br />

Advanced Pack (SAAP).<br />

Storage Storage<br />

Diskette Drive None Standard<br />

Maximum Maximum Maximum Internal<br />

Internal<br />

Storage<br />

Storage<br />

Optical Drive<br />

One of the following<br />

depending on Model<br />

Hard Drives None Standard<br />

None Standard on Entry, High Efficiency, and Base Models<br />

<strong>HP</strong> Slim SATA DVD RW Optical Drive Standard on Performance Models<br />

Hot Plug SFF SAS 4.80TB 16 x 300GB<br />

Hot Plug LFF SAS 6.0TB 6 x 1TB<br />

DA - 13234 Worldwide — Version 5 — May 15, 2009 Page 7