3.4. Modelling<br />

Thermal simulation <strong>of</strong> a building requires the information with respect to the latter’s<br />

dimensions, geometry, orientation and the thermal and optical properties <strong>of</strong> its materials. The<br />

basic physical, thermal and optical material property parameters are used to built Building<br />

element constructions in EnergyPlus are built from in building physics. Materials are specified<br />

by types, while constructions are defined by the composition <strong>of</strong> materials. Finally, surfaces are<br />

specified for the building with geometric coordinates as well as referenced constructions.<br />

There are three material types that may be used to describe layers within opaque construction<br />

elements in EnergyPlus:<br />

• Material: regular,<br />

• Material: regular-R,<br />

• Material: air.<br />

The first type requires knowledge <strong>of</strong> many <strong>of</strong> the thermal, optical and physical properties <strong>of</strong> the<br />

material, but it allows EnergyPlus to take into account the thermal mass <strong>of</strong> the material and thus<br />

allows the evaluation <strong>of</strong> transient conduction effects. The second is similar in nature but only<br />

requires the thermal resistance (R-value) rather than the thickness, thermal conductivity,<br />

density, and specific heat. The last type is only used for an air gap between other layers in a<br />

construction. This type assumes that air is sufficiently lightweight and not moving, so as to<br />

require only an R-value (Papadopoulos, et al. 2008).<br />

In Figure 3.7 shows the first model drawn as nearly real <strong>of</strong> all building<br />

construction. There are lots <strong>of</strong> details about building construction as shown in figure<br />

4.7. But, in this instance, it was not possible to take results. However, when drawing<br />

was simplified such as drawing one skylight instead <strong>of</strong> 22 small skylights, computer can<br />

give results almost in one day. In figure 3.8 shows simplified drawing.<br />