<strong>For</strong> <strong>A6</strong> <strong>Tape</strong> use the following profile:<br />

Ramp for 450°C to 850°C at 6-8C per minute followed by a 10 minute dwell at 850C. The air<br />

flow should be set at 100 SCFH. It is critical that <strong>A6</strong> see 850C for a minimum of 10 minutes<br />

<strong>A6</strong> <strong>Tape</strong> Burn out & Firing Profile<br />

TemperatureC<br />

900<br />

800<br />

700<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

25C<br />

St<strong>and</strong>ard Bakeout <strong>and</strong> Firing Profile for <strong>Ferro</strong> <strong>A6</strong>S <strong>Tape</strong> System<br />

450C<br />

0<br />

0 100 200 300 400 500 600 700<br />

450C<br />

Time in Minutes<br />

850C<br />

Firing Profile is 6C - 8C per minute from 450C-850C with a minimum 10 minute soak<br />

Bakeout Profile is 2C per minute from 250C to 450C with a 2 hour soak<br />

<strong>For</strong> <strong>L8</strong> <strong>Tape</strong> choose from the following profiles:<br />

Box- Ramp for 450°C to 850°C at 4- 8C per minute followed by a 30 minute dwell at 850C<br />

Belt- 16’ (7) Zone furnace with a 0.5” /minute belt speed <strong>and</strong> a set point of 850C –see <strong>L8</strong><br />

Belt profile below –contact <strong>Ferro</strong> for specific Zone air flow <strong>and</strong> temperature settings<br />