GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />

Laser Rotational Shaft Alignment<br />

Fixturlaser Dirigo Laser Bases Shaft<br />

Alignment System<br />

FIX,DIRIGO (4940) AU<br />

Measurement resolution to .01mm Shaft diameter<br />

range 40 to 150mm using an extension chain 150 to<br />

500mm. Maximum distance between measurement<br />

units 0.85m. Very simple to use and operate as<br />

shims are applied the alignment can be monitored<br />

in real time. 20h of operation from alkaline<br />

batteries.<br />

Fixturlaser PAT Pulley Alignment System<br />

FIX,PAT (4941) AU<br />

Laser based alignment system for pulley systems. Measurement accuracy<br />

0.5mm (0.2º). 20hrs of operation on AAA batteries. Mechanically self centres<br />

on pulley, will operate successfully even on worn pulley systems.<br />

Pruftechnik 1500mm length Tension Chains<br />

PRU,AL12.116 (4946) AU<br />

1500mm length tension chains for PRU,ROT-ULTRA<br />

Pruftechnik Rotalign Pro Laser<br />

Shaft Alignment Ex<br />

PRU,ROT-PROEX (4943) AU<br />

Laser based rotating shaft alignment system. Maximum<br />

separation between emitter and receiver 10m. Aligns<br />

horizontal and vertical machines, aligns coupled<br />

and uncoupled shafts equally well. Intrinsically safe<br />

system.<br />

Pruftechnik Rotalign Ultra Laser<br />

Shaft Alignment<br />

PRU,ROT-ULTRA (4945) AU<br />

Laser based rotating shaft alignment<br />

system. Maximum separation between<br />

emitter and receiver 10m. Aligns<br />

horizontal and vertical machines, aligns<br />

coupled and uncoupled shafts equally<br />

well. Ultra modern computer design, backlit colour display, Intel XScale<br />

400MHz CPU, USB for peripheral devices, PC, printer, also Bluetooth<br />

communication. Backlit keyboard, rechargeable Li-Ion battery pack. Machine<br />

train alignment - 14 machines. Alignment results in 3 quick steps, thermal<br />

growth computation. Rotalign Ultra Reader software included.<br />

Industrial Process Calibrators<br />

See also Laboratory Calibrators on page 12<br />

Ametek PPCE 700Bar Pressure Calibrator with NATA Certification<br />

AME,PPCE-NATA (4780) MY<br />

High pressure calibrator with pump 700Bar (10,000psi). Digital display with<br />

5 digit resolution. Accuracy over 70Bar ±0.07. Accuracy below 70Bar ±0.35.<br />

Current and voltage measurement ranges 4 to 20mA, 0 to 50mA & 0 to 30V.<br />

Ametek Hydralyte HL2700N Dead Weight Tester<br />

AME,HL2700N MY<br />

Dual range interchangeable piston: 100 to 4,500kPa, 0.5kPa increments,<br />

500 to 22,500kPa, 1kPa increments. Accuracy 0.05% of reading.<br />

Includes special calculator for high accuracy pressure calculations and also<br />

conversion of units.<br />

48<br />

www.techrentals.com.au<br />

Industrial Process Calibrators cont’d.<br />

Barfield Airspeed and<br />

Altimeter Calibration Kit<br />

BAR,1811KIT (4788) AU<br />

Replacement gauges for the 1811<br />

pitot static tester. This kit will keep<br />

an 1811 calibration system operational during calibration downtime. The<br />

DAS650 is a 650 knot range. The DALT55 is for 55k feet.<br />

Beamex BIC200 Instrument Calibrator<br />

BEA,BIC200 (4752) AU<br />

For both electronic and pneumatic instruments. Output ranges settable<br />

to 119.9% of range 0 to 10V, 1 to 5V, 4 to 20mA, 0 to 20mA, 10 to 50mA<br />

& 0 to 50mA. Output source for current ranges 24 & 48V. Input ranges to<br />

<br />

measurement ranges 0 to 1Bar & 0.2 to 1Bar. Operates from internal NiCd<br />

batteries or external AC.<br />

Beamex MC5 Multifunction NATA Calibrator<br />

BEA,MC5 (4751) AU<br />

Provides calibration capability for pressure,<br />

temperature, electrical and frequency signals.<br />

HART communication and CMX software provided.<br />

Calibration results can be stored or printed.<br />

Performs as a field-entry device (FED) allowing for<br />

the recording of non-calibration related maintenance<br />

results. Pressure modules included, -1 to 20 bar<br />

and 600 bar (up to 1,000 bar with optional external<br />

transducers). DC voltage and current, frequency, and pulse measurement.<br />

RTD, thermocouple, and resistance simulation and measurement.<br />

Beamex MC5 Intrinsically Safe<br />

Multifunction NATA Calibrator<br />

BEA,MC5-IS (4750)<br />

Provides calibration capability for pressure,<br />

temperature, electrical and frequency signals.<br />

HART communication and CMX software provided.<br />

Calibration results can be stored or printed. Performs<br />

as a field-entry device (FED) allowing for the recording of non-calibration<br />

related maintenance results. Pressure measurement range, -1 to 20 bar<br />

and 600 bar (up to 1,000 bar with optional external transducers). DC voltage<br />

& current, frequency, and pulse measurement. RTD, thermocouple, and<br />

resistance simulation & measurement.<br />

Beamex PGXH, PGM and PGV<br />

BEA,PUMPS (4797) AU<br />

Hand pumps includes hand-held, lightweight pressure<br />

and vacuum sources for field use. The PG series of<br />

hand pumps are ideal pressure/vacuum generators<br />

to be used as accessories for pressure and vacuum<br />

calibration. Kit contains PGXH 0 to 700 bar, PGM 0 to<br />

20 bar, PGV 0 to -0.95 bar.<br />

Crystal nVision Pressure<br />

Calibrator 30b IS NATA<br />

CRY,NVISION-30-NATA (4716) AU<br />

Intrinsically safe pressure calibrator. Displays real-time<br />

recorded data graphically on a high res screen with<br />

ability to zoom into specific events. 500,000 data point<br />

memory records all data from all enabled screens from<br />

two modules simultaneously. Fastest logging interval<br />

10 readings/sec. Configured with MA20 current, voltage and switch test<br />

module and 30 bar pressure module, accuracy to 0.025% of reading. Includes<br />

hand pump and CPF (finger tight to 700 bar) fittings.