GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />

Temperature Meters/IR Thermometers<br />

Infrared Thermal Imaging Cameras<br />

Endoscopes Borescopes Visual Inspection<br />

High Speed Video Inspection Cameras<br />

Tachometers/Stroboscopes<br />

Laser Rotational Shaft Alignment<br />

Industrial Process Calibrators<br />

Dry Block & Temperature Calibrators<br />

Strip Chart <strong>Recorders</strong><br />

High Speed Waveform <strong>Recorders</strong><br />

Data Loggers<br />

Pressure & Humidity Transducers<br />

Pressure Vacuum Gauges/<strong>Recorders</strong><br />

Flow Meters for Liquids & Gases<br />

Combustion, Flue & Industrial Gas <strong>Analysers</strong><br />

Environmental Test Chambers/Ovens<br />

Ultrasonic Baths<br />

Temperature Meters/<br />

IR Thermometers<br />

Fluke 52-2 Digital Thermometer<br />

FLU,52-2 MY<br />

Dual input thermocouple thermometer supplied with two K<br />

type thermocouples for differential measurements. Sampling<br />

rate of 1Hz (1 probe) or 1.7Hz (2 probes). Will continuously<br />

record max and min measurements. It also can take K,J,T<br />

and E type Thermocouple inputs. Temperature range: K type:<br />

-200°C to 1,372°C<br />

Fluke 54-2 Dual Input TC<br />

FLU,54-2 (4507) AU<br />

D series 2, dual input digital thermometer with data logging.<br />

Takes J, K, T, E, R, S, N T C inputs. Accuracy ±0.05% +0.3ºC.<br />

500 point logging with date and time stamp. Records min,<br />

max or avg. Logged data can be reviewed on meter or downloaded<br />

via IR port.<br />

Fluke 54-2 Dual Input TC with Flukeview<br />

Logging Software<br />

FLU,54-2FLUKEVIEW (4511) AU<br />

Series 2, dual input digital thermometer with data logging.<br />

Will take most TC inputs. Accuracy ±0.05% +0.3ºC. 500 point<br />

logging with date & time stamp. Also records min, max or avg.<br />

Logged data can be reviewed on meter or downloaded via IR<br />

port RS232 interface, (using cable and Flukeview software<br />

included).<br />

Save your time and reduce your real costs.<br />

Find out all <br />

solutions on page 11.<br />

44<br />

Temperature Meters/<br />

IR Thermometers cont’d.<br />

www.techrentals.com.au<br />

Fluke 576 Photographic Temperature Infrared<br />

Thermometer Built in Camera<br />

FLU,576 (4519) AU/MY<br />

Range -30 to 900ºC. Minimum measurement 19mmØ,<br />

laser class II, 3 point spot. Includes adjustable emissivity<br />

from 0.1 to 1 by 0.01. Target size 1/60 of distance. Max,<br />

min, dif and av displayed on backlit lcd with bar graph.<br />

Data output USB or 1mV/ºC, windows software and<br />

cable included. Accuracy ±0.75% of reading or ±1ºC<br />

whichever is greater. Response time 250ms. Display<br />

resolution 0.1ºC. Continuous measure mode. Digital<br />

camera and flash built in.<br />

Fluke 80TK Thermocouple Module<br />

FLU,80TK (4531) AU<br />

Use with DVM’s and recorders. Accepts K thermocouples. Temperature range<br />

-50 to 1,000ºC. Output 1mV/ºC. Type 80KP-1 probe included.<br />

Fluke 80PK-26 Type-K Thermocouple Probe<br />

FLU,PROBE-TEMP-26 (4535) AU<br />

Type-K thermocouple with tapered tip for use in air, non-caustic gas and<br />

surface applications. Measurement range -40 to 816ºC.<br />

Hart 1521 NATA Precision Handheld<br />

Thermometer<br />

HAR,1521-NATA (4515) AU<br />

Accuracy 0.025ºC. Includes 5615 probe ¼”Ø x 12” long.<br />

Calibrated in the -183 to 500ºC range. Probe operating range<br />

-200 to 420ºC (cable and transition to 150ºC max).<br />

Hart 1523 NATA Precision Handheld<br />

Thermometer<br />

HAR,1523-NATA (4514) AU<br />

Precision, portable, electronic thermometer with trending<br />

and 25 memory positions for NATA-traceable calibration<br />

and high accuracy. Includes 5616 probe 298mm x 6.35mm<br />

100ohm platinum resistance thermometer probe (PRT) -200<br />

to 420°C, stability +/-10mK, accuracy +/-0.012°C at -200°C,<br />

+/-0.011°C at 0°C, +/-0.028°C at 420°C.<br />

Raytek MX6 Photographic Temperature Infrared<br />

Thermometer with built in Camera<br />

RAY,MX6 (4523) AU<br />

Range -30 to 900ºC with built in digital camera. Min<br />

measurement 19mmØ, laser class II, 16 point circle spot.<br />

Includes adjustable emissivity from 0.1 to 1 x 0.01. Target<br />

size 1/60 of distance. Max, min, dif and av display with<br />

backlit lcd with bar graphData output USB or 1mV/ºC,<br />

windows software and cable included. Accuracy ±0.75%<br />

of reading or ±1ºC whichever is greater. Response time<br />

250m/s. Display resolution 0.1ºC. Continuous measure<br />

mode. Digital camera and flash built in.<br />

Testo 845 IR Thermometer with<br />

Humidity Probe and T/C Probe<br />

TES,845 (4527) AU<br />

Temperature measurement -35 to 950°C. Relative humidity<br />

probe 0 to 100%RH. Fast-action surface probe with sprung<br />

thermocouple strip, also for uneven surfaces. Switchable<br />

optical resolution: far field: 75:1 (16mm at a distance<br />

of 1200mm). Close focus: 1mm at a distance of 70mm.<br />

Adjustable emissivity from 0.1 to 1, max, min, displayed<br />

on backlit LCD. Continuous measure mode. Data output<br />

software and cable included. Accuracy ±0.75% of reading<br />

100 to 950°C. Display resolution 0.1°C.