ELECTRICAL POWER<br />

<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />

Hioki 3332 <strong>Power</strong> HiTester Suitable for Standby <strong>Power</strong> Single Phase<br />

HIO,3332 POWERTESTER (8776) AU<br />

Suitable for measuring very low effective power, for stand -by mode of home<br />

equipment. Ultra high-sensitive measurement. Use to measure effective<br />

power of equipment in standby mode: Current 1mA with 0.1μA resolution.<br />

Wide Measurement range, up 5A direct input and auto range facilities are<br />

available. Suitable for single-phase/two wire power measurement. Voltage<br />

measuring ranges from 15V to 600V six ranges, <strong>Power</strong> 15mW to 30kW 90<br />

ranges. Integration range 0 to ± 999999MAh/MWh, integration time up to<br />

10,000 hours. RS232C interface. Other features includes measurement of<br />

inrush current during device start-up, measurement of standby power under<br />

1W, precise calculations of minute stand by power, when 150V/1mA range is<br />

selected, integration from ± 000.000mWh can be performed. Low numbers/<br />

units are automatically switched to a 6 digit display, allowing measurement in<br />

high resolution.<br />

LEM Topas 1000<br />

<strong>Power</strong> Network Analyser<br />

LEM,TOPAS1000 (8762) AU<br />

Measures all relevant parameters in one<br />

measurement system. Inputs (isolated) voltage<br />

4 channels, 200mV to 1kV, current 4 channels,<br />

supplied with 4 x 0 to 10A, 10 to 100A AC<br />

clamp-on CTs and 4 x (unit powered) 0 to 3kA LEM-Flex current sensors.<br />

Can be configured for 8 voltage channels. Measuring functions RMS, V(U)<br />

voltage imbalance, positive, negative & zero phase sequence, phasor (vector)<br />

diagrams, amps (I)a, pf, kVA, kVAr, f(Hz), energy, on-line oscilloscope, power<br />

and multimeter, harmonics (by power/direction, magnitude & phase), interharmonics,<br />

THD, flicker, transients (100kHz to 10MHz), will capture events<br />

from 0.1μs in duration. Software configured manual or auto trigger levels,<br />

ethernet or serial interface, memory >540Mb/HDD.<br />

Megger MMC850 Multi/Single Core AC<br />

Clampmeter - 200 Amps<br />

MEG,MMC850CLAMPMETER (8776) AU<br />

Multi/Single Core AC. Clampmeter single, two or three core<br />

cable measurement. Flat or round section cables; no need<br />

to split wires. Measures up to 200A on single-core, 100A on<br />

multi-core cables. Cable centralising clamp, backlit display,<br />

50Hz and 60Hz supplies, IEC 1010-2-032, CAT III 600V<br />

safety protection.<br />

Megger SK-MDP3 Distribution<br />

Profiler 1000Amps/35kV<br />

MEG,SK-MDP3 (8727) AU<br />

Records currents up to 1,000A, plus 200A over-range.<br />

Waveform capture and harmonic analysis up to the 32nd<br />

order. <strong>Power</strong> factor/power and relative voltage RMS<br />

magnitude, overhead line spring attachment, accurate data<br />

capture via advanced MDP software, Lightweight battery<br />

operated, weather resistant. Easy plug-in for quick data<br />

retrieval.<br />

<br />

MET,MX2040 (8811) AU<br />

Measures A, V, Hz, kW, kVA, kVAR, kWH, PF and resistance.<br />

Ranges 200A & 2kA, 600V & 1kV, 20, 200kW & 2MW &<br />

kWH. Scale length 3,000. 1 & 3ph operation. Motor rotation<br />

indication. Peak, min, max, average, RMS, and crest factor<br />

indication. Peak response time 1μs. Analogue output option<br />

fitted giving dynamic signals and calculated parameters<br />

(energy, etc). Jaw opening 55mm for 22 x 64 bars.<br />

36<br />

<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />

Metrosonics PF-1-F Overhead Profiler<br />

MET,PF-1-F (8726) AU<br />

Distribution line profilers for current measurement on power lines. Logs current<br />

consumption to internal memory. Set of 3 profilers with one display module.<br />

Windows software included. Current range 5 to 1,000A. Resolution 1A.<br />

Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate 1s to<br />

10min. Memory 64k readings. Data storage modes: stop when full or wrap<br />

around. Data retention after low battery shutdown 30d. Min conductor spacing<br />

600mm.<br />

AC Electrical Chart <strong>Recorders</strong><br />

Hioki 9132 Clip-on AC Current Transducer<br />

HIO,9132 (8604) AU<br />

Ranges 20 to 1kA fs. Short term overload capability 2kA. Output 0.2VAC. For<br />

use with Hioki 8800 series recorders, for current waveform recording.<br />

Current Clamp Probes & Accessories<br />

See also Electrical Testers on page 29 & 30<br />

See also <strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> on page 32-36<br />

www.techrentals.com.au<br />

CHK 3 Phase Converter for CTs 1A Input to 200mA Output<br />

CHK,CK1 (8791) AU<br />

Adaptor for CTs with 1A secondary outputs, this unit suits CHK,PM30/20.<br />

CHK 3 Phase Converter for CTs 5A Input to 200mA Output<br />

CHK,CK5 (8785) AU<br />

Adaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.<br />

CHK CR100 Clamp-on CT<br />

CHK,CR100 (8782) AU/MY<br />

Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CR500 Clamp-on 500 CT<br />

CHK,CR500 (8789) AU<br />

Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to<br />

measure neutral current. Accuracy Class 1.<br />

CHK CT1000L Large 1kA Primary Clamp-on CT<br />

CHK,CT1000L (8796) AU<br />

Large 123 x 35mm 1kA primary clamp-on CT for CHK,PM20/30.<br />

CHK CT3000L Large 3kA Primary Clamp-on CT<br />

CHK,CT3000L (8790) AU<br />

Large 123 x 35mm 3kA primary clamp-on CT for CHK,PM20/30.<br />

Dranetz Communications Adapter<br />

- Fibre to Ethernet with Node Link<br />

Software<br />

DRA-BMI,CAF-ETHERNET (8709) AU<br />

Communications Adapter-Fibre to Ethernet<br />

with NodeLink Software and Moxa<br />

Networking Software for the following<br />

Dranetz-BMI Models: DRA-BMI,PX5, DRA-<br />

BMI, PX5-400, DRA-BMI,PG4400.