Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ELECTRICAL POWER<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
CHK PM35 <strong>Power</strong> Quality<br />
Analyser/Logger<br />
CHK,PM35 (8788) MY<br />
<strong>Power</strong> logger and disturbance analyser. Weatherproof<br />
IP65 field unit. 3 Voltage (55 to 520VAC) and 4 current<br />
(0 to 3,000A) channels. Supplied with 4 flexible<br />
3,000A clamp-on CTs (flexible CT length 600mm<br />
and 190mmØ). Memory: 15Mb. Inbuilt two line LCD<br />
display. Records: V, A, pf, f(Hz), kVA, kVAr, kW,<br />
harmonics, (THD and individual to 48th ). Flicker (Pst & Plt), Total energy,<br />
tariffs, maximum demands, transient and sub-cycle disturbances. Included<br />
software provides graphs and summaries to PC. Download files while logging.<br />
High speed USB interface. A PC using Windows 95, 98, NT4, WIN2000 or<br />
XP (Vista in compatability mode)O/S, is required with the software to configure<br />
this unit before operating.<br />
CHK Gridsense PM40 <strong>Power</strong> Quality<br />
Analyser<br />
CHK,PM40PQA (8779) AU<br />
Weatherproof IP65 field unit. Channels: 3 Voltage,<br />
63 to 440V (isolated). 4 current 0 to 3,000A (3ph<br />
and neutral) RMS. Supplied with 4 flexible 3,000A<br />
clamp-on CTs (flexible CT length 600mm and Diameter<br />
190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits<br />
LCD display, 7 rows x 20 characters. Records: V, A,<br />
pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics,<br />
voltage and current imbalance (THD and individual<br />
to 48th ) and Flicker. Total energy, tariffs, maximum<br />
demands, and transient and sub-cycle disturbances. Included software<br />
provides graphs and summaries to PC. Download files while logging USB<br />
interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required<br />
with the CHK <strong>Power</strong>View software to configure this unit before operating.<br />
CHK PM45 <strong>Power</strong> Quality Analyser<br />
CHK,PM45 (8779) AU<br />
Suitable for low voltage investigations,<br />
power profiling and load studies, harmonic analysis,<br />
power factor studies & flicker and imbalance<br />
monitoring. Features IEC61010 Cat IV 600V safety<br />
certificate, weatherproof IP65 case, 4 channel<br />
voltage and 4 channels current. Supplied with 4 x<br />
Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd<br />
0 to 60VAC, Current input 0 to 3,000A.<br />
Dranetz-BMI <strong>Power</strong> Guide 4400<br />
DRA-BMI,PG4400 (8700) AU<br />
Provides the full range of<br />
measurements include V, I, W, VA, VAR,<br />
TPF, DPF, demand, energy, harmonics &<br />
inter-harmonics, THD, harmonics spectrum<br />
<br />
factor, K factor, transformer de-rating etc.<br />
<br />
range 30/300/3,000A AC only. Can be extended to different ranges of<br />
measurement AC/DC by selecting appropriate current clamps. Has the full<br />
range of arithmetic, vector and sequence parameters to evaluate distorted and<br />
<br />
active parameter can trigger logging. Voltage & current disturbances. DRA-<br />
BMI,PG4400 analysers can be used for power quality measurements, current<br />
inrush fault recording long term monitoring and continuous logging at 1s intervals.<br />
DRA-BMI,PG4400 is Class A compliant with IEC Standard 61000-4-30,<br />
AS61000-4-7 and AS61000-4-15.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
34<br />
www.techrentals.com.au<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
Dranetz-BMI <strong>Power</strong> Xplorer PX5<br />
DRA-BMI,PX5 (8701) AU<br />
Provides the full range of measurements<br />
include V, I, W, VA, VAR, TPF, DPF, Demand,<br />
Energy, Harmonics & Inter-harmonics, THD,<br />
Harmonics spectrum (V, I, W) to the 63rd,<br />
Flicker (Pst, Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/<br />
Avg values are determined in ½ cycle RMS steps. Complete with A/C Flexible<br />
Current Clamp DRA-BMI,RR3035A/24, Current Range:- 30/300/3,000A AC<br />
only. Can be extended to mentioned different ranges of measurement both<br />
AC/DC by selecting appropriate current clamps. High-speed transient capture<br />
(1MHz sampling rate) and full range of arithmetic, vector and sequence<br />
parameters to evaluate distorted and un-balanced loads as defined in IEEE<br />
1459. Exceeding high/low limits of any active parameter can trigger logging.<br />
Voltage and current disturbances can be triggered by peak value, wave-shape<br />
change and cycle-by-cycle RMS value change. Pre-event and post-event<br />
waveform capture cycles are user adjustable. Voltage and current channels<br />
can be cross-triggered. Can be used for power quality measurements,<br />
current inrush (cycle-by-cycle current logging), fault recording (cycle-bycycle<br />
voltage logging), long term monitoring and continuous logging at 1s<br />
intervals. The four differential voltages and current channels can also be<br />
used independently. Class A compliant with IEC Standard 61000-4-30 ‘<strong>Power</strong><br />
Quality Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic<br />
& Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data<br />
is collected at 256 samples/cycle/channel.<br />
Fluke VR1710 Single-Phase Voltage<br />
Quality Recorder<br />
FLU,VR1710 (8734) AU<br />
Single phase power quality analyser. Records RMS,<br />
transients, flicker & harmonics up to the 32nd. Selectable<br />
logging periods from 1s to 20min. Provides continuous<br />
recording with no gaps. Includes software for download,<br />
analysis and automatic reporting.<br />
Hioki 2332-20 RPMS SmartSite Remote<br />
<strong>Power</strong> Measurement System<br />
HIO,2332-20RPMS (8715) AU<br />
For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3<br />
wire & 3ph 3 wire up to 3 circuits. Provides via a PC, management of<br />
measurement data to support energy and environmental management.<br />
Modulated measurement units take advantage of a variety of infrastructure<br />
to collect measurement data. Use as a stand alone logger and for remote<br />
monitoring. Use as a PC measurement logger keeps measuring and continuously<br />
saves the data. Measurement modules comes with memory and clock.<br />
Build a customised and remote measuring system by utilizing existing data<br />
network. Modules for temperature, humidity, instrumentation and pulse, power<br />
module for multiple circuits. Large internal memory. Communication module<br />
with built-in real-time clock tracks - resolution 1s. Air Module for constructing<br />
SS wireless systems.<br />
Hioki 3169-21 Clamp-On<br />
<br />
500 Amps CT’s<br />
HIO,3169-21 CT500AMP (8718) AU<br />
Measurement of single-phase to<br />
three-phase 4-wire circuits with a single<br />
unit. In addition to measuring standard parameters such voltage, current,<br />
power, power factor, and integrated values, can simultaneously perform<br />
demand measurements required for carrying out power management and<br />
energy-saving measures, as well as harmonic measurements. Features:<br />
Measure up to 3-phase, 3-wire system (displays voltage and current for<br />
three lines), Measure up to four single-phase, 2-wire systems, up to 500A<br />
range, compact and light weight, power recording for individual waveforms,<br />
simultaneousrecording of demand values and harmonics. RS-232C interface<br />
for PC communications, supplied with Hioki 9625 <strong>Power</strong> Measurement<br />
Support Software for data analysis. Includes 4 x Hioki 9667 500A CTs.