ELECTRICAL POWER<br />

<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />

CHK PM35 <strong>Power</strong> Quality<br />

Analyser/Logger<br />

CHK,PM35 (8788) MY<br />

<strong>Power</strong> logger and disturbance analyser. Weatherproof<br />

IP65 field unit. 3 Voltage (55 to 520VAC) and 4 current<br />

(0 to 3,000A) channels. Supplied with 4 flexible<br />

3,000A clamp-on CTs (flexible CT length 600mm<br />

and 190mmØ). Memory: 15Mb. Inbuilt two line LCD<br />

display. Records: V, A, pf, f(Hz), kVA, kVAr, kW,<br />

harmonics, (THD and individual to 48th ). Flicker (Pst & Plt), Total energy,<br />

tariffs, maximum demands, transient and sub-cycle disturbances. Included<br />

software provides graphs and summaries to PC. Download files while logging.<br />

High speed USB interface. A PC using Windows 95, 98, NT4, WIN2000 or<br />

XP (Vista in compatability mode)O/S, is required with the software to configure<br />

this unit before operating.<br />

CHK Gridsense PM40 <strong>Power</strong> Quality<br />

Analyser<br />

CHK,PM40PQA (8779) AU<br />

Weatherproof IP65 field unit. Channels: 3 Voltage,<br />

63 to 440V (isolated). 4 current 0 to 3,000A (3ph<br />

and neutral) RMS. Supplied with 4 flexible 3,000A<br />

clamp-on CTs (flexible CT length 600mm and Diameter<br />

190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits<br />

LCD display, 7 rows x 20 characters. Records: V, A,<br />

pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics,<br />

voltage and current imbalance (THD and individual<br />

to 48th ) and Flicker. Total energy, tariffs, maximum<br />

demands, and transient and sub-cycle disturbances. Included software<br />

provides graphs and summaries to PC. Download files while logging USB<br />

interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required<br />

with the CHK <strong>Power</strong>View software to configure this unit before operating.<br />

CHK PM45 <strong>Power</strong> Quality Analyser<br />

CHK,PM45 (8779) AU<br />

Suitable for low voltage investigations,<br />

power profiling and load studies, harmonic analysis,<br />

power factor studies & flicker and imbalance<br />

monitoring. Features IEC61010 Cat IV 600V safety<br />

certificate, weatherproof IP65 case, 4 channel<br />

voltage and 4 channels current. Supplied with 4 x<br />

Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd<br />

0 to 60VAC, Current input 0 to 3,000A.<br />

Dranetz-BMI <strong>Power</strong> Guide 4400<br />

DRA-BMI,PG4400 (8700) AU<br />

Provides the full range of<br />

measurements include V, I, W, VA, VAR,<br />

TPF, DPF, demand, energy, harmonics &<br />

inter-harmonics, THD, harmonics spectrum<br />

<br />

factor, K factor, transformer de-rating etc.<br />

<br />

range 30/300/3,000A AC only. Can be extended to different ranges of<br />

measurement AC/DC by selecting appropriate current clamps. Has the full<br />

range of arithmetic, vector and sequence parameters to evaluate distorted and<br />

<br />

active parameter can trigger logging. Voltage & current disturbances. DRA-<br />

BMI,PG4400 analysers can be used for power quality measurements, current<br />

inrush fault recording long term monitoring and continuous logging at 1s intervals.<br />

DRA-BMI,PG4400 is Class A compliant with IEC Standard 61000-4-30,<br />

AS61000-4-7 and AS61000-4-15.<br />

Save your time and reduce your real costs.<br />

Find out all <br />

solutions on page 11.<br />

34<br />

www.techrentals.com.au<br />

<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />

Dranetz-BMI <strong>Power</strong> Xplorer PX5<br />

DRA-BMI,PX5 (8701) AU<br />

Provides the full range of measurements<br />

include V, I, W, VA, VAR, TPF, DPF, Demand,<br />

Energy, Harmonics & Inter-harmonics, THD,<br />

Harmonics spectrum (V, I, W) to the 63rd,<br />

Flicker (Pst, Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/<br />

Avg values are determined in ½ cycle RMS steps. Complete with A/C Flexible<br />

Current Clamp DRA-BMI,RR3035A/24, Current Range:- 30/300/3,000A AC<br />

only. Can be extended to mentioned different ranges of measurement both<br />

AC/DC by selecting appropriate current clamps. High-speed transient capture<br />

(1MHz sampling rate) and full range of arithmetic, vector and sequence<br />

parameters to evaluate distorted and un-balanced loads as defined in IEEE<br />

1459. Exceeding high/low limits of any active parameter can trigger logging.<br />

Voltage and current disturbances can be triggered by peak value, wave-shape<br />

change and cycle-by-cycle RMS value change. Pre-event and post-event<br />

waveform capture cycles are user adjustable. Voltage and current channels<br />

can be cross-triggered. Can be used for power quality measurements,<br />

current inrush (cycle-by-cycle current logging), fault recording (cycle-bycycle<br />

voltage logging), long term monitoring and continuous logging at 1s<br />

intervals. The four differential voltages and current channels can also be<br />

used independently. Class A compliant with IEC Standard 61000-4-30 ‘<strong>Power</strong><br />

Quality Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic<br />

& Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data<br />

is collected at 256 samples/cycle/channel.<br />

Fluke VR1710 Single-Phase Voltage<br />

Quality Recorder<br />

FLU,VR1710 (8734) AU<br />

Single phase power quality analyser. Records RMS,<br />

transients, flicker & harmonics up to the 32nd. Selectable<br />

logging periods from 1s to 20min. Provides continuous<br />

recording with no gaps. Includes software for download,<br />

analysis and automatic reporting.<br />

Hioki 2332-20 RPMS SmartSite Remote<br />

<strong>Power</strong> Measurement System<br />

HIO,2332-20RPMS (8715) AU<br />

For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3<br />

wire & 3ph 3 wire up to 3 circuits. Provides via a PC, management of<br />

measurement data to support energy and environmental management.<br />

Modulated measurement units take advantage of a variety of infrastructure<br />

to collect measurement data. Use as a stand alone logger and for remote<br />

monitoring. Use as a PC measurement logger keeps measuring and continuously<br />

saves the data. Measurement modules comes with memory and clock.<br />

Build a customised and remote measuring system by utilizing existing data<br />

network. Modules for temperature, humidity, instrumentation and pulse, power<br />

module for multiple circuits. Large internal memory. Communication module<br />

with built-in real-time clock tracks - resolution 1s. Air Module for constructing<br />

SS wireless systems.<br />

Hioki 3169-21 Clamp-On<br />

<br />

500 Amps CT’s<br />

HIO,3169-21 CT500AMP (8718) AU<br />

Measurement of single-phase to<br />

three-phase 4-wire circuits with a single<br />

unit. In addition to measuring standard parameters such voltage, current,<br />

power, power factor, and integrated values, can simultaneously perform<br />

demand measurements required for carrying out power management and<br />

energy-saving measures, as well as harmonic measurements. Features:<br />

Measure up to 3-phase, 3-wire system (displays voltage and current for<br />

three lines), Measure up to four single-phase, 2-wire systems, up to 500A<br />

range, compact and light weight, power recording for individual waveforms,<br />

simultaneousrecording of demand values and harmonics. RS-232C interface<br />

for PC communications, supplied with Hioki 9625 <strong>Power</strong> Measurement<br />

Support Software for data analysis. Includes 4 x Hioki 9667 500A CTs.