Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ELECTRICAL POWER<br />
Micro-Ohm Meters & Earth Testers<br />
cont’d.<br />
Megger DLRO200 200A Micro-Ohm Meter<br />
MEG,DLRO200 (1265) AU<br />
Test currents from 10A to 200ADC. 0.1 microohm<br />
resolution. Weight 14.5kg On board memory for<br />
up to 300 test results and notes. RS232 download<br />
of stored results onto PC or printer.<br />
Megger DLRO600 Digital Micro-Ohm Meter - High current<br />
MEG,DLRO600 (1268) AU/MY<br />
<br />
currents from 10A to 600A subject to the load resistance and supply voltage.<br />
A large backlit liquid crystal display provides all the information needed to<br />
perform a test; all test parameters and measurement results are displayed.<br />
<br />
Accuracy: Voltage ±0.5% ± 0.1mV. Current ±0.5% ± 0.1A. Resistance:<br />
<br />
detail]. <strong>Power</strong> supply for: full output: 207 to 265V 50/60Hz with a load less than<br />
<br />
load]. Reduced output: Down to 100V 50/60Hz [refer to data sheet for detail].<br />
Test Current Range: 10A to 600A unsmoothed DC in 1A steps. Accuracy:<br />
±2% ±2A. Test Modes: Manual, Auto, Continuous. Test Time: 7 seconds<br />
normal /auto mode. Refreshed every 2 seconds in continuous mode. Voltmeter<br />
input impedance: >200kW. Data Transfer: Real time or batch download<br />
via RS232 using AVO Download Manager. Storage Capacity: 300 result sets.<br />
Megger DLRO Wind Turbine<br />
Lightning<br />
Protection Test Lead Set<br />
MEG,DLRO-100LEAD (1263) AU<br />
For Megger DLRO 10 series digital microohm<br />
meters. Specially designed for measuring<br />
resistance of lightning protection circuit between<br />
wind turbine blade tip and ground. Kelvin clip<br />
and hook ends on 100m cable reel. 5m DH2<br />
lead with duplex hand spikes and hook end.<br />
Megger DLRO lead set Current & Voltage Leads<br />
MEG,DLRO-LEADSET (1263) AU<br />
For Megger DLRO digital micro-ohm meters potential spike lead set x2 and<br />
current clip lead set x2. Leads are used to separate the C & P connections.<br />
This avoids the erroneously high readings taken due to a high resistance<br />
contact. Current clip lead set 2m (242041-7) and Potential Spike set 2m<br />
(242021-7).<br />
Megger LT330 Non-tripping Loop Tester, 3Ph Safe,<br />
1ph or ph-ph<br />
MEG,LT330 EN-AU (8445) AU<br />
Non-tripping loop tester. 3 phase safe, single or phase-phase loop testing. 2<br />
wire test (high current). Single phase loop testing. Phase - Phase loop testing.<br />
L-N-E polarity indicators. PFC display. Phase rotation indicator. Frequency<br />
<br />
storage & download via USB. IP54 weatherproof. IEC61010-1 300v CAT III.<br />
EN61557.<br />
T&R DSM200 200A Micro-Ohm Meter<br />
T&R,DSM200 (1264) AU<br />
<br />
with RS232 output. AC mains operation. Complete with 3m leads.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
32<br />
www.techrentals.com.au<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong><br />
See also Current Clamps Probes & Accessories on page 36-38<br />
CCI <strong>Power</strong>-Mate 15A Single Phase<br />
<strong>Power</strong>/Energy Measurements<br />
CCI,POWER-MATE 15A (8803) AU<br />
Can accurately measure and calculate power, volts, amps and<br />
energy being used by an electrical appliance. Also measures<br />
the greenhouse gas emission created by an appliance. Can<br />
determine the actual running cost, how much energy the<br />
appliance used in kilowatt-hours and how many kilograms of<br />
greenhouse gas emissions it produced all in hourly, yearly,<br />
quarterly and accumulated figures. Features an LED display for easy reading<br />
and high visibility at all times. 15 amp version - to a maximum continuous<br />
capacity of 15A, but readings are accurate to 18A and the cable is rated to<br />
15A. Provides a variety of measurements including: power in watts, voltage<br />
and current. Provides the minimum, maximum as well as instantaneous<br />
readings.<br />
CHK PM20 <strong>Power</strong> Quality<br />
Analyser/Logger<br />
CHK,PM20 MY<br />
Three phase, weatherproof IP65 field unit. Three voltage<br />
channels 63 to 440V (isolated). Four current<br />
channels 0 to 3kA RMS (3ph & neutral). Supplied with<br />
3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA<br />
for large conductors and 500A for neutrals clamp-on<br />
CTs are available. Memory 4Mb. In-built 2 line LCD<br />
display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and tariffs,<br />
high speed RMS waveform capture events outside preset limits (10ms intervals).<br />
Software provides graphs and summaries to PC. Download files while<br />
logging. RS232 interface. PC using Win 95, 98 or NT4 O/S, is required with the<br />
CHK POWERview software to configure this unit before operating.<br />
CHK Gridsense PM30 3 Phase<br />
<strong>Power</strong>monic <strong>Power</strong> Logger<br />
CHK,PM30 (8788) AU/MY<br />
Weatherproof IP65 field unit. Channels 3 voltage, 63<br />
to 440V (isolated), 4 current 0 to 3kA (3ph & neutral)<br />
RMS. Supplied with 3 x 1kA clamp-on CTs (cable<br />
capacity 50mm). Clamp-on CTs of 3kA, 1kA for large<br />
conductors and 500A & 100A for neutral conductor<br />
current measurement are available. Memory 4Mb.<br />
In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics,<br />
(THD and individual to 48th). Total energy, tariffs, max demands, transient<br />
and sub-cycle disturbances. Software provides graphs and summaries to PC.<br />
Download files while logging via RS232 interface. PC using Win 95, 98, NT4,<br />
2000, XP, O/S, is required with the CHK POWERview software to configure<br />
this unit before operating.<br />
CHK Gridsense PM30<br />
Plus 3 Phase <strong>Power</strong>monic Logger<br />
CHK,PM30PLUS (8778) AU/MY<br />
Weatherproof IP65 field unit. Channels: 3 Voltage,<br />
63 to 440V (isolated). 3 current 30 to 3,000A (3ph)<br />
rms. Supplied with 3 flexible 3,000A clamp-on CTs<br />
(flexible CT length 600mm and 190mmØ). (In addition,<br />
clamp-on CTs of 3,000A, 1,000A for large conductors<br />
and 500A and 100A for neutral conductor current<br />
measurement are available.) Memory: 4Mb. Inbuilt<br />
two line LCD display. Records: V, A, pf, f(Hz), kVA,<br />
kVAr, kW, harmonics, (THD and individual to 48th). Total energy, tariffs,<br />
maximum demands, transient and sub-cycle disturbances. Included software<br />
provides graphs and summaries to PC. Download files while logging RS-232<br />
interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required<br />
with the CHK POWERview software to configure this unit before operating.