12.10.2013 Views

Power Analysers & Recorders cont'd. - Ferret

Power Analysers & Recorders cont'd. - Ferret

Power Analysers & Recorders cont'd. - Ferret

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ELECTRICAL POWER<br />

Electrical Testers cont’d.<br />

CATU C-8-36 Phasing Stick - Two Pole Phase<br />

Comparator for Indoor Use<br />

CAT,CL-8-36 PH STICK (8728) AU<br />

Detects differences in voltage between any two<br />

points of an installation indicated by LED’s. It also<br />

enables assessment of the order of magnitude<br />

of the residual voltage induced by nearby live lines or circuits, and thus<br />

differentiates it from the one provided directly from a high voltage source. Main<br />

features are wide range of voltages 2kV to 36kV, high luminosity, compact:<br />

620mm with probes dismounted, high dielectric quality insulating material. Two<br />

1.25m elements with removable probes, connected via a high-insulation lead,<br />

maximum use distance: 2.25m (with probe extenders). Operation testing: with<br />

a checking device.<br />

Hioki 3283 Clamp on Leak HiTester<br />

HIO,3283 CLAMP ON-LT (8804) AU<br />

Easily monitor leak current fluctuations. Wide bandwidth,<br />

5Hz to 15kHz (Waveform output), high-sensitivity with a full<br />

scale of 10mA (resolution:10μA). High-accuracy at ±1 %,<br />

True RMS measurement, analyser functions, for filtering<br />

and output signals. AC current range; 10mA to 200A AC, 5<br />

ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC,<br />

1 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), effective value<br />

rectifier. Frequency characteristics (at AC current /voltage)<br />

40 to 2kHz.<br />

Martindale Phase Sequence & Continuity<br />

Indicator 100 to 600V, 50/60Hz<br />

MAR,PSCI424-585 (1233) AU<br />

Tester may be used, on 3ph circuits, to check the<br />

presence & sequence of the phases. Important<br />

on motor circuits as a phase reversal will cause a<br />

motors direction to reverse. Tester will give visual<br />

indication of loss of phase or an incorrect sequence.<br />

Tester is supplied in 2 forms - Probe style, the<br />

connection to the tester is via 3 insulated cables to<br />

3 fused test probes, 1 with an insulated crocodile<br />

clip. Plug style, a 16A, 4 pin, 3ph & earth, BS4343<br />

plug is fitted to the tester. Use as a socket tester prior to plugging in 3ph<br />

equipment. Testers supplied in a plastic wallet, with full instructions. Caution,<br />

the unit should be checked for correct operation using a known voltage before<br />

use.<br />

PAT Testers & RCD Testers<br />

Megger LTW335 Fault Loop<br />

Impedance Tester<br />

MEG,LTW335-FLIT (2612) AU<br />

2 Wire Non-tripping loop tester. 50V to 440V<br />

operation, 110V centre-tap loop testing,<br />

CATIV installation testing, AUTO start -<br />

<br />

<br />

Megger RCDT330 Residual Current Device Tester<br />

MEG,RCDT330 (2618) AU<br />

Tests standard, DC, selection and programmable RCDs. Ramp testing. Auto<br />

(remote) testing. Auto sequence test feature. 3ph safe. Enables testing on 110V<br />

centre tapped supplies. Performs 1/2I, 1xI & 50xI tests on RCDs rated at 10mA,<br />

30mA, 100mA, 300mA, 500mA & 1,000mA on general and selective (time<br />

delayed) RCDs. Weatherproof to IP54. USB interface for test results download.<br />

30<br />

www.techrentals.com.au<br />

PAT Testers & RCD Testers cont’d.<br />

Metrel IT3017- Installation<br />

Tester for Testing to AS/<br />

NZS3000<br />

MET,IT3017INSTALTEST (2610) AU<br />

Multifunction installation tester with<br />

measurement functions and Pass/Fail<br />

<br />

storing of test results for printing compliance test reports. In-built Australian<br />

measurements and Pass/Fail limits, and guarantees accountability and<br />

traceability with storing of test results. Simply conduct the test, press the<br />

Memory button to save the result and assign the result to a location, then<br />

download results to PC software and print-out compliance test reports with<br />

actual test results. Earth Continuity & Resistance, Insulation Resistance,<br />

Polarity, Correct Circuit Connections, Fault Loop Impedance and RCD<br />

Testing. “Auto-Sequence Test” mode further speeds up compliance testing<br />

and reporting.<br />

Metrel MI 2121 AUS Advanced RCD Tester<br />

MET,MI2121AUS (2620) AU<br />

<br />

Stores upto 1,000 tests. Interface RS232 Software. Fast<br />

testing of 10,30, 100, 300, 500, 1,000mA RCD’s both<br />

standard (I, II, III) and selective (IV) AC types. With 50%, 100%, 200% and<br />

500% nominal test current for all ranges. Sinusoidal trip current for reliable<br />

operation. Selectable phase angle 0 degree (positive) and 180 degree<br />

(negative). Measures RCD trip time and current, phase voltage to 470V.<br />

1,000 test result memory logging. Results download software.<br />

Seaward PAC 3760 Appliance Checker<br />

SEW,PAC3760 (2605) AU<br />

Performs the following tests in conformance to AS/<br />

<br />

tests, also leakage current tests for Class I & Class II<br />

appliances and leads (leakage current testing of<br />

appliances, which requires power to “switch” them on,<br />

<br />

pass/fail indication. Unique 3 button operation. Class I,<br />

class II and leakage current. Automatic test sequence<br />

senses an IEC or extension lead then performs a<br />

polarity test. Detects that the appliance under test is<br />

switched “On”. Earth bond test is set at 10A and is capable<br />

of fusing a poor earth.<br />

Seaward ProTag OPTIMA-300 Testing<br />

and Tagging System<br />

SEW,PT-300 (2603) AU<br />

Comprises the Seaward PrimeTest 300 appliance and<br />

RCD tester, ProTag Optima test tag printer and the BCS-<br />

Blue bar code scanner. Battery powered, weighs around<br />

<br />

for appliances and leads, and 30mA RCD tests. Operates<br />

as a handheld data logging device by recording any type<br />

of test, inspection or risk assessment with user defined<br />

inspection routines and an in-built library of measurement<br />

and engineering units for recording actual results.<br />

Trolley Suitable for SEW,XE3760PKIT+ Supernova PAT Tester<br />

SEW,TROLLEY-3760PKIT (2608) AU<br />

<br />

5 socket extension board socket 240V/10A, extension cable approximately<br />

25 meters, 2 elastic tie ropes and a plastic bin.