Example DTMF Report String<br />

Federal Signal <strong>UltraVoice</strong><br />

Installation and Operation <strong>Manual</strong><br />

Received DTMF report string = * 0 D 3 D D 5 7 C 1 0 B 6 *<br />

*<br />

Starting character<br />

OPTIONS<br />

75<br />

Description of Status Report<br />

0 Siren type MOD6024 (six amplifiers)<br />

D3 Currently running code (0000) (0011) which equals the number 03.<br />

DD5 Siren site number (0000) (0000) (0101), which equals site number 005<br />

7 Sensor status is (0111), Bit 1 is 1, Amp 1 is bad or not active<br />

Bit 2 is 1, Amp 2 is bad or not active<br />

Bit 3 is 1, Amp 3 is bad or not active<br />

Bit 4 is 0, Amp 4 is active and good<br />

C Sensor status is (1111), Bit 1 is 1, Amp 5 is bad or not active<br />

Bit 2 is 1, Amp 6 is bad or not active<br />

Bit 3 is 1, Amp 7 is bad or not active<br />

Bit 4 is 1, Amp 8 is bad or not active<br />

1 Sensor status is (0001), Bit 1 is 1, Amp 9 is bad or not active<br />

Bit 2 is 0, Amp 10 is active and good<br />

Bit 3 is 0, Amp 11 is active and good<br />

Bit 4 is 0, Amp 12 is active and good<br />

0 Sensor status is (1010), Bit 1 is 0, Battery is good<br />

Bit 2 is 1, Master Current is not active<br />

Bit 3 is 0, Signal B is active<br />

Bit 4 is 1, Signal A is not active<br />

B Sensor status is (1110), Bit 1 is 0, Intrusion has not occurred in cabinet 1<br />

Bit 2 is 1, Not used<br />

Bit 3 is 1, AC power is off<br />

Bit 4 is 1, Charger is active<br />

6 Sensor status is (0110), Bit 1 is 0, Rotation has occurred<br />

Bit 2 is 1, Not used, input not active<br />

Bit 3 is 1, Spare is not active<br />

Bit 4 is 0, False alarm has occurred<br />

* Terminating character<br />

For serial transmission, the above report string is converted to an 8-bit ASCII value by<br />

adding an offset of 30 Hex.