Federal Signal <strong>UltraVoice</strong><br />

Installation and Operation <strong>Manual</strong><br />

motherboard is operating (indicated by LED<br />

D2). Also check fuses F1 and F2 on<br />

motherboard.<br />

PROBLEM ACTION<br />

9. RADIO PA TAKES TOO LONG<br />

TO TIME OUT<br />

10. LANDLINE ACTIVATION INPUTS<br />

DO NOT FUNCTION<br />

Check radio for proper operation of squelch.<br />

CD LED should light while carrier is present.<br />

Verify minimum 0.5 second contact closure<br />

is applied to JP14 on the motherboard.<br />

NOTE: For additional help contact the FWS Service Dept. at (800) 524-3021.<br />