Federal Signal <strong>UltraVoice</strong><br />
Installation and Operation <strong>Manual</strong><br />
2. Set for same level<br />
as the standard<br />
siren sounds.<br />
7.7 Troubleshooting<br />
MAINTENANCE<br />
67<br />
3. Ensure that the<br />
sound is not<br />
distorted.<br />
PROBLEM ACTION<br />
1. NO RADIO DECODE A. Unit was not armed before sending a<br />
DTMF function code (or) Unit is not<br />
programmed to recognize that particular<br />
code sequence (or) Signal is not being<br />
received properly.<br />
B. Verify programming is correct. Check the<br />
received audio signal quality at the RX test<br />
pin on the front of the control board.<br />
2. NO TWO TONE DECODE Decoder not programmed. Check radio<br />
connections if external (see wiring diagram).<br />
Check for proper C/D polarity setting. Insure<br />
that radio is working properly by using a<br />
service monitor to inject a strong, clean<br />
3. LOW OUTPUT FROM SPEAKER<br />
ARRAY<br />
4. FUNCTION STOPS BEFORE<br />
NORMAL TIME-OUT<br />
signal. Check transmitter deviation.<br />
Check battery voltage. Check speaker<br />
impedance (see maintenance section).<br />
Also, check signal indicators on amplifiers<br />
during a function. If indicators are off,<br />
remove amplifier for service.<br />
Batteries may require further charging.<br />
Check battery voltage under load. Check<br />
charger output.<br />
5. LOCAL PA FEEDS BACK Lower PA volume using knob above MIC<br />
connector.<br />
6. LOCAL PA HAS LITTLE OR NO<br />
OUTPUT<br />
7. BATTERIES NOT HOLDING<br />
CHARGE<br />
Hold MIC close to mouth. Increase PA<br />
volume using knob above MIC connector.<br />
Check that charger fuses are intact and<br />
check charger output.<br />
Load test batteries.<br />
8. EOWS*612 DOES NOT ROTATE Check that the rotation relay on the system