WARNING<br />
Electrocution or severe personal injury<br />
can occur when making electrical<br />
connections, drilling holes, or lifting<br />
equipment. Therefore, installation<br />
should be performed by experienced<br />
electricians in accordance with national<br />
and local electrical codes.<br />
WARNING<br />
The output level of a Modulator Series<br />
siren is capable of causing permanent<br />
hearing damage. To prevent excessive<br />
exposure to civilians, carefully plan<br />
placement of siren and post warnings.<br />
To prevent excessive exposure to<br />
installers and service personnel,<br />
adequate measures must be taken to<br />
ensure that the sirens are not activated<br />
while they are within 150 feet of the<br />
speaker array or provide proper ear<br />
protection.<br />
5.0 Siren Controller Installation<br />
A. General<br />
Most siren installations are one of two<br />
types: Pole Mount or Flat Surface Mount.<br />
These two (2) configurations make it<br />
possible to install a siren in almost any<br />
situation. If the installations in this<br />
paragraph are not suitable, modification<br />
of one of the configurations may be<br />
practical.<br />
Many factors affect the propagation of<br />
sound over various types of terrain and<br />
Federal Signal <strong>UltraVoice</strong><br />
Installation and Operation <strong>Manual</strong><br />
SECTION V<br />
INSTALLATION<br />
INSTALLATION<br />
30<br />
changing weather conditions. Consult<br />
FEMA CPG 1-17 and CPG 1-14 and your<br />
local Federal Signal representative to<br />
properly place your outdoor warning<br />
equipment.<br />
B. Pole Mounting<br />
A typical pole mounted siren installation is<br />
shown in the figure below. The siren is<br />
mounted on Class 2 utility pole (ANSI<br />
type wooden pole or equivalent) with a<br />
minimum horizontal ground stress rating<br />
of 3,700 pounds (1682 kg). (Insure that<br />
soil loads will conform to this size utility<br />
pole.)<br />
NOTE: Certain soil conditions may<br />
require guying for the pole. Check with<br />
proper building authorities<br />
NOTE: The speaker array installation is<br />
covered in a separate set of instructions<br />
supplied with the array.<br />
To install the ULTRAVOICE control unit<br />
to a wooden utility pole, proceed as<br />
follows:<br />
1. Uncrate the siren control. Remove<br />
the plastic bag attached to the<br />
conduit that is connected between<br />
the control and the battery box.<br />
2. Unlock the control box and the<br />
battery box. Inspect the control<br />
and battery box for any damage.<br />
Report any damage immediately to<br />
the shipping company and file a<br />
claim. Inform Federal Signal of the<br />
damage.